One document matched: draft-quittek-power-mib-01.txt
Differences from draft-quittek-power-mib-00.txt
Network Working Group J. Quittek, Ed.
Internet-Draft R. Winter
Intended status: Standards Track T. Dietz
Expires: October 24, 2010 D. Dudkowski
NEC Europe Ltd.
April 22, 2010
Definiton of Managed Objects for Energy Management
draft-quittek-power-mib-01.txt
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes extensions to the Entity MIB to provide
information about the energy consumption, the power states and
battery status of managed devices and their components.
Status of this Memo
This Internet-Draft is submitted to IETF in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as Internet-
Drafts.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt.
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
This Internet-Draft will expire on October 24, 2010.
Copyright Notice
Copyright (c) 2010 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Quittek, et al. draft-quittek-power-mib-01.txt [Page 1]
Internet-Draft Power MIB Modules April 2010
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the BSD License.
Table of Contents
1. The Internet-Standard Management Framework . . . . . . . . . . 3
2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Power State MIB . . . . . . . . . . . . . . . . . . . . . . . 5
3.1. Current Power State Table . . . . . . . . . . . . . . . . 5
3.2. Power State Table . . . . . . . . . . . . . . . . . . . . 6
4. Energy MIB . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.1. Energy Consumption Table . . . . . . . . . . . . . . . . . 7
4.2. Energy Consumption Per Power State Table . . . . . . . . . 8
4.3. Power History Table . . . . . . . . . . . . . . . . . . . 8
5. Battery MIB . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Relationship to Other MIB Modules . . . . . . . . . . . . . . 11
6.1. Entity MIB . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2. Entity State MIB . . . . . . . . . . . . . . . . . . . . . 12
6.3. Entity Sensor MIB . . . . . . . . . . . . . . . . . . . . 12
6.4. UPS MIB . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.5. Power Ethernet MIB . . . . . . . . . . . . . . . . . . . . 12
7. Definitions . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1. Power State MIB . . . . . . . . . . . . . . . . . . . . . 13
7.2. Energy MIB . . . . . . . . . . . . . . . . . . . . . . . . 20
7.3. Battery MIB . . . . . . . . . . . . . . . . . . . . . . . 41
8. Security Considerations . . . . . . . . . . . . . . . . . . . 53
9. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 54
10. References . . . . . . . . . . . . . . . . . . . . . . . . . . 54
10.1. Normative References . . . . . . . . . . . . . . . . . . . 54
10.2. Informative References . . . . . . . . . . . . . . . . . . 55
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 55
Quittek, et al. draft-quittek-power-mib-01.txt [Page 2]
Internet-Draft Power MIB Modules April 2010
1. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies MIB
modules that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58,RFC 2580
[RFC2580].
2. Introduction
Energy management in communication networks is a topic that has been
neglected for many years when energy was cheap and global warming not
recognized. This has changed recently. Energy management is
becoming a significant component of network planning, operations and
management and new energy management strategies are currently being
explored.
A basic requirement for many energy management procedures is
collecting information on energy consumption and energy storage at
managed devices. Most devices consume less energy when they are in
standby mode compared to their consumption when providing full
service. Therefore, management systems will have a need to monitor
power state information when conducting basic energy management
functions.
But the actual energy consumption of a device depends on more than
just its power state. Also the current load, the kind of load, and
many other factors influence energy consumption. If instrumentation
is available, it is very helpful to receive information on the actual
energy consumption of a device or of a device's component. Providing
this information requires much more effort than reporting power
states, because a probe that measures (electrical) power consumption
is required. Typically this means not just adding several lines of
software to a device, but also adding costly sensor hardware to it.
A third aspect to be considered for energy management is energy
storage in batteries. It is helpful, for example, to monitor which
device is running on batteries and which is charging its battery.
Fortunately, the problem of instrumentation is often an easy one for
devices with rechargeable batteries. Controlling the charging cycles
Quittek, et al. draft-quittek-power-mib-01.txt [Page 3]
Internet-Draft Power MIB Modules April 2010
needs instrumentation anyway and this instrumentation can also be
used for providing battery status information.
This document defines a portion of the Management Information Base
(MIB) that serves the three purposes sketched above:
o monitoring power states of managed entities,
o monitoring energy consumption of managed entities,
o monitoring the status of batteries contained in or controlled by
managed devices.
Supporting all three monitoring task will not make sense for every
device. Many networked devices do not have batteries to be monitored
and thus it would not make sense for them to implement managed
objects for this purpose.
As mentioned above, instrumentation for measuring actual energy
consumption is relatively expensive and it will not make sense for
every managed device to provide sufficient instrumentation. In such
a case it would not be appropriate to still implement managed objects
for energy consumption monitoring.
This leads to the conclusion that the portions of the MIB for the
three monitoring tasks listed above should be rather independent of
each other and not combined in a single one. This document contains
three MIB modules called Power State MIB, Energy MIB, and Battery
MIB. The Energy MIB module uses an object defined in the Power State
MIB module, but beyond that there is no dependency between the three
modules. Obviously, any combination of the three modules is
possible.
The definitions in this document are based on the requirements
outlined in [I-D.quittek-power-monitoring-requirements].
All three MIB modules are designed as extensions to the Entity MIB
module [RFC4133]. They all contain sparse augments of the
entPhysicalTable defined in [RFC4133]. The entPhysicalTable already
provides information about physical entities such as their type,
name, software revision number, serial number, etc., and about their
containment in other entities. This is all re-used for entities that
have different power states, for which energy consumption can be
measured, or that are batteries.
Sparse augmentation of the entPhysicalTable means that tables in the
three MIB modules use the index of the entPhysicalTable as their
first index. The augment is sparse, because not for every row in the
entPhysicalTable there needs to be a row in the tables defined in the
MIB modules in this document. For example, the batteryTable will
only have rows for index values of the entPhysicalTable that refer to
Quittek, et al. draft-quittek-power-mib-01.txt [Page 4]
Internet-Draft Power MIB Modules April 2010
an entity that is a battery.
Augmentation also means that rows in the tables defined in this
document should be created at the same time when the corresponding
entry in the entPhysicalTable is created. They also should be
destroyed, when the corresponding rows in the entPhysicalTable are
destroyed.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [RFC2119].
3. Power State MIB
A number of devices today can operate in a number of different power
states by reducing performance or going into standby mode or sleep
mode. The Power State MIB module can be used for monitoring these
states. Typically, not much instrumentation is needed for supporting
the power state MIB module, because most devices with different power
states are already equipped with means for controlling their these.
The Power State MIB module is structured into two tables, the
powerCurrentStateTable reporting the current power state of an entity
and the powerStateTable providing statistics per power state. Both
tables use the object entPhysicalIndex from the Entity MIB module
[RFC4133] as first index. In addition, the Power State MIB module
defines a notification that can be sent for informing the receiver
about a change of an entity's current power state.
3.1. Current Power State Table
For basic monitoring of the actual power state of an entity, there is
already a MIB module available: the Entity State MIB [RFC4268]. It
reports the power state of an entity in object entStateStandby. It
can have four different values: unknown(1), hotStandby(2),
coldStandby(3), providingService(4), see ENTITY-STATE-TC-MIB in
[RFC4268].
If this was considered to be sufficient, there would be no need for
replicating this object in the power state MIB module. However,
there is a concern that the three "known" states are too few for
reflecting the variety of power saving states available today. For
PCs, for example, there are several more states defined for the
Advanced Configuration & Power Interface (ACPI). It might be useful
to support several or all of these power states as suggested by
[I-D.claise-energy-monitoring-mib].
Quittek, et al. draft-quittek-power-mib-01.txt [Page 5]
Internet-Draft Power MIB Modules April 2010
The powerCurrentStateTable contains just a single object per row:
powerCurrentStateTable(1)
+--powerCurrentStateEntry(1) [entPhysicalIndex]
+-- r-n EntityStandbyStatus powerCurrentState(1)
Object powerCurrentState reports the actual power state of an entity
at the time the object's value is retrieved. In the current
definition of the MIB module, it just reports the four values defined
for the Entity State MIB module. It does not make sense to keep it
like this by just replicating existing functionality. Either the
range of supporting values will be extended or the
powerCurrentStateTable will be removed from the Power State MIB
module. It is currently there as a placeholder until discussion on
the number of power states to be supported comes to a conclusion.
3.2. Power State Table
The second table called powerStateTable provides more detailed
statistics for each power state. For this purpose it uses the power
state value as another index object next to the entity index. This
way, statistics can be reported per entity and per power state. The
second index has the syntax of a SnmpAdminString and can be defined
by the manufacturer of the device or MIB. In this way the index can
fit many devices because the characteristics of the power state can
be defined per device. The characteristics of the power state SHOULD
be described as closely as possible in the object
powerStateDescription.
powerStateTable(2)
+--powerStateEntry(1) [entPhysicalIndex,powerState]
+-- --- SnmpAdminString powerState(1)
+-- r-n SnmpAdminString powerStateDescription(2)
+-- r-n TimeTicks powerStateTotalTime(3)
+-- r-n TimeStamp powerStateLastEnterTime(4)
+-- r-n SnmpAdminString powerStateLastEnterReason(5)
+-- r-n Counter64 powerStateEnterCount(6)
+-- r-n EntitySensorValue powerStateAveragePower(7)
+-- r-n EntitySensorValue powerStateMaximumPower(8)
The offered statistics include the total time that the entity spent
in a certain power state (powerStateTotalTime), the last time at
which the entity entered a power state (powerStateLastEnterTime), the
reason for entering it at the last time (powerStateLastEnterReason),
the number of times a certain state has been entered
(powerStateEnterCount), the average power consumed by the entity
(powerStateAveragePower) and the maximum power consumed by the entity
(powerStateMaximumPower).
Quittek, et al. draft-quittek-power-mib-01.txt [Page 6]
Internet-Draft Power MIB Modules April 2010
4. Energy MIB
Devices that have instrumentation for measuring electrical energy
consumption of entities can implement the Energy MIB module.
Entities for which energy consumption is reported can be the entire
devices, a component thereof or even an external entity for which the
reporting devices observes the energy consumption.
The Energy MIB module defines two tables, the energyConsumpTable and
the energyConsumpPSTable. The first one provides information on the
instrumentations and on measured energy consumption of the entity.
The second one provides energy consumption information for each
individual power state.
4.1. Energy Consumption Table
The first set of managed objects in the energyConsumpTable are needed
to help interpreting the energy consumption readings. These include
the power supply type and voltage.
energyConsumpTable(1)
+--energyConsumpEntry(1) [entPhysicalIndex]
+-- r-n EntitySensorStatus energyConsumpSensorOperStatus(1)
+-- r-n Unsigned32 energyConsumpNominalSupplyVoltage(2)
+-- r-n Enumeration energyConsumpElectricSupplyType(3)
+-- r-n EntitySensorValue energyConsumpTotalEnergy(4)
+-- r-n EntitySensorDataScale energyConsumpEnergyScale(5)
+-- r-n EntitySensorPrecision energyConsumpEnergyPrecision(6)
+-- r-n EntitySensorPrecision energyConsumpEnergyFractionDigits(6)
+-- r-n EnergySensorMaxError energyConsumpEnergyMaxError(7)
+-- r-n Enumeration energyConsumpMeasurementMethod(8)
+-- r-n TimeStamp energyConsumpDiscontinuityTime(9)
+-- r-n EntitySensorDataScale energyConsumpPowerScale(10)
+-- r-n EntitySensorPrecision energyConsumpPowerFractionDigits(11)
+-- r-n EnergySensorMaxError energyConsumpPowerMaxError(12)
+-- r-n Unsigned32 energyConsumpPowerSampleInterval(13)
+-- r-n Unsigned32 energyConsumpPowerMaxHistory(14)
+-- r-n EntitySensorValue energyConsumpRealPower(15)
+-- r-n EntitySensorValue energyConsumpPeakRealPower(16)
+-- r-n EntitySensorValue energyConsumpReactivePower(17)
+-- r-n EntitySensorValue energyConsumpApparentPower(18)
+-- r-n EntitySensorValue energyConsumpPhaseAngle(19)
+-- r-n EnergySensorMaxError energyConsumpPhaseAngleMaxError(20)
The main measured values provided by the table are the total energy
consumed by the device and the current power (energy consumption
rate). For entities supplied with alternating current (AC) there are
also objects defined for reporting apparent power, reactive power and
Quittek, et al. draft-quittek-power-mib-01.txt [Page 7]
Internet-Draft Power MIB Modules April 2010
phase angle.
All measured values are defined to be of type EntitySensorValue
defined by the Entity Sensor MIB module [RFC3433]. For this data
type scale and nuber of fractional decimal places in the fractional
part can be specified by additional objects of types
EntitySensorDataScale and EntitySensorPrecision. The
energyConsumpTable makes use of this mechanism and contains a set of
objects for this purpose. In addition, objects of type
EnergySensorMaxError specify the maximum difference between the
reported value obtained by measurement and the actual value.
Measurements of the total energy consumed by an entity may suffer
from interruptions in the continuous measurement of the current
energy consumption. In order to indicate such interruptions, object
energyConsumpDiscontinuityTime is provided for indicating the time of
the last interruption of total energy measurement.
Time series of average power (or aggregated energy consumption) for
past time intervals are stored in the energyPowerHistoryTable.
Objects energyConsumpPowerSampleInterval and
energyConsumpPowerMaxHistory control the generation of entries in
this table, see below.
4.2. Energy Consumption Per Power State Table
The second table in this module is called energyConsumpPSTable and it
provides values of total energy consumption per power state in a way
similar to the powerStateTable in the Power State MIB module.
energyConsumpPSTable(2)
+--energyConsumpPSEntry(1) [entPhysicalIndex,powerState]
+-- r-n EntitySensorValue energyConsumpPSTotalEnergy(1)
4.3. Power History Table
The third table in this module is the energyPowerHistoryTable. It
stores average power and peak power values for past time intervals.
From the aberage power values, energy consumption in the intervals
can be determined by multiplying them by the length of the time
interval.
energyPowerHistoryTable(3)
+--energyPowerHistoryEntry(1) [entPhysicalIndex,
| energyPowerHistoryIndex]
+-- --- Unsigned32 energyPowerHistoryIndex(1)
+-- r-n TimeStamp energyPowerHistoryTimestamp(2)
+-- r-n EntitySensorValue energyPowerHistoryAverageValue(3)
Quittek, et al. draft-quittek-power-mib-01.txt [Page 8]
Internet-Draft Power MIB Modules April 2010
+-- r-n EntitySensorValue energyPowerHistoryPeakValue(4)
Creation of entries in this table is controlled by the values of
corresponding objects energyConsumpPowerSampleInterval and
energyConsumpPowerMaxHistory in the energyConsumpTable.
Entries are indexed by the the entity (entPhysicalIndex) and by
energyPowerHistoryIndex. The first entry created for a certain
entity in the table always has an energyPowerHistoryIndex with a
value of 1. Further entries for the same entity get increasing
consecutive indices until the maximum index value given by object
energyConsumpPowerMaxHistory is reached. Then, no further indices
will be used, but the entry with the oldest timestamp will be
overwritten each time a new entry needs to be created.
A new entry is created with a time difference given by object
energyConsumpPowerSampleInterval after creation of the previous
entry. Hence, the difference between timestamps
energyPowerHistoryTimestamp of two consecutive entries SHOULD be
equal to the value of object energyConsumpPowerSampleInterval.
Object energyPowerHistoryTimestamp indicates the end of the
measurement time interval. The start of the time interval is usually
given by the time stamp of the previous entry in the table.
In most cases, the previous entry can be identified by the value of
index energyPowerHistoryIndex. If the index of the current entry has
a value greater than 1, then the index of the previous entry has a
value that is one less than the current one.
If the value of the current index energyPowerHistoryIndex equals 1,
then there may be no previous entry or the previous entry has an
index value that is equal to the value of the corresponding object
energyConsumpPowerMaxHistory in the energyConsumpTable. If such en
entry exists and if its timestamp is earlier than the timestamp of
the current entry, then this one is the previous entry. Otherwise,
there is no previous entry.
If there is no previous entry, then the interval length is given by
the value of the corresponding object
energyConsumpPowerSampleInterval in the energyConsumpTable.
An entry contains two power values. They indicates the average power
and the peak power, respectively, during the relevant time interval.
Average power and peak can be measured in different ways. The least
accurate way is just estimating it based on the entity's current load
and/or power state. Power can also be measured with a power mether
Quittek, et al. draft-quittek-power-mib-01.txt [Page 9]
Internet-Draft Power MIB Modules April 2010
just once within the interval, preferably a the end of the interval
as close to the timestamp value as possible. In this case, both
objects energyPowerHistoryAverageValue and
energyPowerHistoryPeakValue have the same value. If multiple
measurements of the actual power are performed within the interval,
then object energyPowerHistoryAverageValue contains the average of
all measured values and object energyPowerHistoryPeakValue contains
the largest of all measured values.
In case the energy sensor can directly measure the consumed energy
within the interval, then the value of object
energyPowerHistoryAverageValue is computed by dividing the energy
consumption by the length of the interval.
5. Battery MIB
The third MIB module defined in this document defines objects for
reporting information about batteries. The batteryTable contained in
the Batter MIB module is again a sparse augment of the Entity MIB
module [RFC4133]. It uses one row per battery and require that every
battery for which information is provided has its own entry in the
entPhysicalTable of the Entity MIB module.
The kind of entity in the entPhysicalTable is indicated by the value
of enumeration object entPhysicalClass. Since there is no value
called 'battery' defined for this object, it is RECOMMENDED that for
batteries the value of this object is chosen to be powerSupply(6).
The batteryTable contains three groups of objects. The first group
describes the battery in more detail than the generic objects in the
entPhysicalTable. The second group of objects report on the current
battery state, if it is charging or discharging, how much it is
charged, its remaining capacity, the number of experienced charging
cycles, etc.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 10]
Internet-Draft Power MIB Modules April 2010
batteryTable(1)
+--batteryEntry(1) [entPhysicalIndex]
+-- r-n Enumeration batteryType(1)
+-- r-n Enumeration batteryTechnology(2)
+-- r-n Unsigned32 batteryNominalVoltage(3)
+-- r-n Unsigned32 batteryNumberOfCells(4)
+-- r-n Unsigned32 batteryNominalCapacity(5)
+-- r-n Unsigned32 batteryRemainingCapacity(6)
+-- r-n Counter32 batteryChargingCycleCount(7)
+-- r-n DateAndTime batteryLastChargingCycleTime(8)
+-- r-n Enumeration batteryState(9)
+-- r-n Unsigned32 batteryCurrentCharge(10)
+-- r-n Unsigned32 batteryCurrentChargePercentage(11)
+-- r-n Unsigned32 batteryCurrentVoltage(12)
+-- r-n Integer32 batteryCurrentCurrent(13)
+-- r-n Unsigned32 batteryLowAlarmPercentage(14)
+-- r-n Unsigned32 batteryLowAlarmVoltage(15)
+-- r-n Unsigned32 batteryReplacementAlarmCapacity(16)
+-- r-n Unsigned32 batteryReplacementAlarmCycles(17)
The third group of objects in this table indicates thresholds which
can be used to raise an alarm if a property of the battery exceeds
one of them. Raising an alarm may include sending a notification.
The Battery MIB defines two notifications, one indicating a low
battery charging state and one indicating an aged battery that may
need to be replaced.
6. Relationship to Other MIB Modules
The three MIB modules described above relate to a number of existing
standard MIB modules and complements them where necessary.
6.1. Entity MIB
All MIB modules defined in this document implement a sparse
augmentation of the entPhysicalTable defined in the Entity MIB module
[RFC4133]. This means that tables defined in the MIB modules in this
document use the index of the entPhysicalTable called
entPhysicalIndex as their first index, in most cases as their only
index. The augmentation is sparse meaning that entries in tables
defined in this document do not need to create entries for all
entries that exist in the entPhysicalTable. Entries can be
restricted to relevant ones, for example, the batteryTable can
restrict their entries to entities that are a battery.
The advantage of augmenting the Entity MIB instead of defining new
tables from scratch is the re-use of many objects in the
Quittek, et al. draft-quittek-power-mib-01.txt [Page 11]
Internet-Draft Power MIB Modules April 2010
entPhysicalTable. For example, the kind of entity
(entPhysicalClass), the serial number (entPhysicalSerialNum), the
software version (entPhysicalSoftwareRev) and many other properties
are covered by objects in the entPhysicalTable as well as the
containment relationship between entities. The containment
relationship indicates, for example, in which device a battery entity
is contained.
6.2. Entity State MIB
The Entity State MIB module [RFC4268] defines object entStateStandby
in the entStateTable. This object provides information on the power
state. This object may have one of four defined values: unknown(1),
hotStandby(2), coldStandby(3), providingService(4). If this number
was considered to be sufficient, the powerCurrentStateTable of the
Power State MIB module would be obsolete and should be removed.
However, there are concerns that this number is not sufficient.
Discussions in the IETF will hopefully soon lead to a consensus on
which is the better way to go.
6.3. Entity Sensor MIB
The Entity Sensor MIB module [RFC3433] defines generic objects for
providing data from sensors such as, for example, an energy
consumption meter. Basically, some of the objects defined in the
Energy MIB module could be replaced by objects in the Entity Sensor
MIB module. However, in the Entity Sensor MIB module more objects
are needed to model the same information and flexibility is not fully
sufficient. For example, there is no unit for energy supported, such
as, for example, watt hours; a sampling interval for the sensor
cannot be specified, and there is not support for reporting
discontinuities of accumulated measurements, such as the total
consumed energy. For these reasons, the Energy MIB was defined as
new module instead of using the Entity Sensor MIB module.
6.4. UPS MIB
Relations to UPS MIB module [RFC1628] are still to be done.
6.5. Power Ethernet MIB
Relations to Power Ethernet MIB module [RFC3621] are still to be
done.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 12]
Internet-Draft Power MIB Modules April 2010
7. Definitions
7.1. Power State MIB
POWER-STATE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
mib-2, Counter64, TimeTicks
FROM SNMPv2-SMI -- RFC2578
TimeStamp
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC2580
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC3411
EntitySensorValue
FROM ENTITY-SENSOR-MIB -- RFC3433
entPhysicalIndex
FROM ENTITY-MIB; -- RFC4133
powerStateMIB MODULE-IDENTITY
LAST-UPDATED "201001291200Z" -- 29 January 2010
ORGANIZATION "IETF OPSAWG Working Group"
CONTACT-INFO
"General Discussion: opsawg@ietf.org
To Subscribe: https://www.ietf.org/mailman/listinfo/opsawg
Archive: http://www.ietf.org/mail-archive/web/opsawg
Co-editor:
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-128
Email: Thomas.Dietz@neclab.eu
Co-editor:
Juergen Quittek
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Tel: +49 6221 4342-115
Email: quittek@neclab.eu"
Quittek, et al. draft-quittek-power-mib-01.txt [Page 13]
Internet-Draft Power MIB Modules April 2010
DESCRIPTION
"This MIB module defines a set of objects for monitoring
the power state of networked devices and their components.
Copyright (c) 2009 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).
This version of this MIB module is part of RFC yyyy; see
the RFC itself for full legal notices."
-- replace yyyy with actual RFC number & remove this notice
-- Revision history
REVISION "201001291200Z" -- 29 January 2010
DESCRIPTION
"Initial version, published as RFC yyyy."
-- replace yyyy with actual RFC number & remove this notice
::= { mib-2 xxx }
-- xxx to be assigned by IANA.
--******************************************************************
-- Top Level Structure of the MIB module
--******************************************************************
powerStateNotifications OBJECT IDENTIFIER ::= { powerStateMIB 0 }
powerStateObjects OBJECT IDENTIFIER ::= { powerStateMIB 1 }
powerStateConformance OBJECT IDENTIFIER ::= { powerStateMIB 2 }
--==================================================================
-- 1. Object Definitions
--==================================================================
--------------------------------------------------------------------
-- 1.1. Current Power State Table
--------------------------------------------------------------------
powerCurrentStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerCurrentStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Quittek, et al. draft-quittek-power-mib-01.txt [Page 14]
Internet-Draft Power MIB Modules April 2010
"This table provides information on the current power state
of entities.
This is a sparse augment of the entPhysicalTable.
Entries appear in this table for entities for which their
power state can be reported.
An entry in this table SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed."
::= { powerStateObjects 1 }
powerCurrentStateEntry OBJECT-TYPE
SYNTAX PowerCurrentStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information on the current power state
of an entity."
INDEX { entPhysicalIndex } -- SPARSE-AUGMENTS
::= { powerCurrentStateTable 1 }
PowerCurrentStateEntry ::=
SEQUENCE {
powerCurrentState SnmpAdminString
}
powerCurrentState OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current power state of the
entity indicated by the index entPhysicalIndex. The given
SnmpAdminString MUST match the powerState object of an enry
in the powerStateTable."
::= { powerCurrentStateEntry 1 }
--------------------------------------------------------------------
-- 1.2. Power State Statistics Table
--------------------------------------------------------------------
powerStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides information on the current power state
Quittek, et al. draft-quittek-power-mib-01.txt [Page 15]
Internet-Draft Power MIB Modules April 2010
of entities.
This is a sparse augment of the entPhysicalTable.
Entries appear in this table for entities for which
statistics on their power state can be reported.
An entry in this table SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed.
As second index for this table serves the power state of the
entity indicated by the first index.
This index does not predefine power states to accommodate
most of the devices out there. Every device has different
power characteristics and power states and thus a fixed
schema would be too restrictive to fit them all. The object
powerStateDescription SHOULD describe the power state
and its characteristica as closely as possible."
::= { powerStateObjects 2 }
powerStateEntry OBJECT-TYPE
SYNTAX PowerStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power state information about this physical entity."
INDEX { entPhysicalIndex, powerState }
::= { powerStateTable 1 }
PowerStateEntry ::=
SEQUENCE {
powerState SnmpAdminString,
powerStateDescription SnmpAdminString,
powerStateTotalTime TimeTicks,
powerStateLastEnterTime TimeStamp,
powerStateLastEnterReason SnmpAdminString,
powerStateEnterCount Counter64,
powerStateAveragePower EntitySensorValue,
powerStateMaximumPower EntitySensorValue
}
powerState OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index should only be created for power states
Quittek, et al. draft-quittek-power-mib-01.txt [Page 16]
Internet-Draft Power MIB Modules April 2010
that are actually used by the entity that is identified
by the first index entPhysicalIndex.
This index is the name of the power state and is limited
to 32 characters.
If possible the name SHOULD already give a rough idea of the
characteristica of this power state."
::= { powerStateEntry 1 }
powerStateDescription OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the power state given with
energyConsumpPSIndex. It SHOULD describe the characteristica
of the power state as closely as possible."
::= { powerStateEntry 2 }
powerStateTotalTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total time in hundreds
of seconds that the entity has been in the state
indicated by index powerState."
::= { powerStateEntry 3 }
--------------------------
-- Open issue: Shall we use DateAndTime instead of timeTicks?
--------------------------
powerStateLastEnterTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time stamp object indicates the last
time a which the entity entered the state
indicated by index powerState."
::= { powerStateEntry 4 }
powerStateLastEnterReason OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Quittek, et al. draft-quittek-power-mib-01.txt [Page 17]
Internet-Draft Power MIB Modules April 2010
"This string object describes the reason for the last
power state transition into the power state
indicated by index powerState."
::= { powerStateEntry 5 }
powerStateEnterCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates how often the entity
indicated by index entPhysicalIndex entered the
power state indicated by index powerState."
::= { powerStateEntry 6 }
powerStateAveragePower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the average power consumed in
millivolt at the electrical power supply of the entity.
Scale and precision of the value are indicated
by objects energyConsumpPowerScale and
energyConsumpPowerPrecision.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of
energyConsumpDiscontinuityTime.
The previous three objects mentioned above can be found in
the ENERGY-MIB."
::= { powerStateEntry 7 }
powerStateMaximumPower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the maximum power consumed in
millivolt at the electrical power supply of the entity.
Scale and precision of the value are indicated
by objects energyConsumpPowerScale and
Quittek, et al. draft-quittek-power-mib-01.txt [Page 18]
Internet-Draft Power MIB Modules April 2010
energyConsumpPowerPrecision.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of
energyConsumpDiscontinuityTime.
The previous three objects mentioned above can be found in
the ENERGY-MIB."
::= { powerStateEntry 8 }
--==================================================================
-- 2. Notifications
--==================================================================
powerStateChangeEvent NOTIFICATION-TYPE
OBJECTS { powerStateLastEnterReason }
STATUS current
DESCRIPTION
"This notification can be generated when the power state of
an entity changes.
Note that the state that has been entered is indicated by
the OID of object powerStateLastEnterReason."
::= { powerStateNotifications 1 }
--==================================================================
-- 3. Conformance Information
--==================================================================
powerStateCompliances OBJECT IDENTIFIER
::= { powerStateConformance 1 }
powerStateGroups OBJECT IDENTIFIER
::= { powerStateConformance 2 }
--------------------------------------------------------------------
-- 3.1. Compliance Statements
--------------------------------------------------------------------
powerCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for implementations of the
POWER-STATE-MIB module.
A compliant implementation MUST implement the objects
Quittek, et al. draft-quittek-power-mib-01.txt [Page 19]
Internet-Draft Power MIB Modules April 2010
defined in the mandatory group powerRequiredGroup."
MODULE -- this module
MANDATORY-GROUPS { powerStateRequiredGroup }
GROUP powerStateNotificationsGroup
DESCRIPTION
"A compliant implementation does not have to implement
the powerNotificationsGroup."
::= { powerStateCompliances 1 }
--------------------------------------------------------------------
-- 3.2. MIB Grouping
--------------------------------------------------------------------
powerStateRequiredGroup OBJECT-GROUP
OBJECTS {
powerCurrentState,
powerStateDescription,
powerStateTotalTime,
powerStateLastEnterTime,
powerStateLastEnterReason,
powerStateEnterCount,
powerStateAveragePower,
powerStateMaximumPower
}
STATUS current
DESCRIPTION
"A compliant implementation MUST implement the objects
contained in this group."
::= { powerStateGroups 1 }
powerStateNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { powerStateChangeEvent }
STATUS current
DESCRIPTION
"A compliant implementation does not have to implement the
notification contained in this group."
::= { powerStateGroups 2 }
END
7.2. Energy MIB
ENERGY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, mib-2,
Unsigned32, Integer32
FROM SNMPv2-SMI -- RFC2578
TEXTUAL-CONVENTION, TimeStamp
Quittek, et al. draft-quittek-power-mib-01.txt [Page 20]
Internet-Draft Power MIB Modules April 2010
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC2580
entPhysicalIndex
FROM ENTITY-MIB -- RFC4133
EntitySensorDataScale, EntitySensorPrecision,
EntitySensorValue, EntitySensorStatus
FROM ENTITY-SENSOR-MIB -- RFC3433
powerState
FROM POWER-STATE-MIB;
energyMIB MODULE-IDENTITY
LAST-UPDATED "201001291200Z" -- 29 January 2010
ORGANIZATION "IETF OPSAWG Working Group"
CONTACT-INFO
"General Discussion: opsawg@ietf.org
To Subscribe: https://www.ietf.org/mailman/listinfo/opsawg
Archive: http://www.ietf.org/mail-archive/web/opsawg
Co-editor:
Juergen Quittek
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Tel: +49 6221 4342-115
Email: quittek@neclab.eu
Co-editor:
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-128
Email: Thomas.Dietz@neclab.eu"
DESCRIPTION
"This MIB module defines a set of objects for monitoring
the energy consumption of networked devices and their
components.
Copyright (c) 2010 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
Quittek, et al. draft-quittek-power-mib-01.txt [Page 21]
Internet-Draft Power MIB Modules April 2010
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).
This version of this MIB module is part of RFC yyyy; see
the RFC itself for full legal notices."
-- replace yyyy with actual RFC number & remove this notice
-- Revision history
REVISION "201001291200Z" -- 29 January 2010
DESCRIPTION
"Initial version, published as RFC yyyy."
-- replace yyyy with actual RFC number & remove this notice
::= { mib-2 yyy }
-- yyy to be assigned by IANA.
--==================================================================
-- 1. Textual Conventions
--==================================================================
EnergySensorMaxError ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"An object using this data type represents the maximal
error of a sensor value.
An object of this type SHOULD be defined together with
objects of type EntitySensorDataType, EntitySensorDataScale,
and EntitySensorPrecision. Together, associated objects of
these four types are used to identify the semantics and
accuracy of an object of type EntitySensorValue.
The maximum error of a measured value reported by a sensor
is often given as percentage of the maximum value of the
sensor range. Here it is given differently as the product
of the maximum value and the percentage value. The value
is typically a few orders of magnitude smaller than values
reported by the sensor.
The value of this object is interpreted in the same way as
the value of the associated object of type EntitySensorValue
with the only difference that the value of the associated
object of type EntitySensorDataScale is reduced by one for
Quittek, et al. draft-quittek-power-mib-01.txt [Page 22]
Internet-Draft Power MIB Modules April 2010
interpreting the maximum error.
This implies that the the interpretation of a value of type
EntitySensorValue and a value of type EnergySensorMaxError
differs by a factor of 1000. If, for example, the value of
an object of type EntitySensorDataScale milli(8), then for
the interpretation of this object a data scale value of
micro(7) is used. If the associated object of type
EntitySensorDataScale has a value of yocto(1) (10^-24), then
for the interpretation of this object a scaling factor of
10^-27 is applied.
For example, a physical entity representing a temperature
sensor that can measure 0 degrees to 100 degrees C in 0.1
degree increments with an accurqcy of +/- 0.2 degree would
have an EntitySensorPrecision value of '1', an
EntitySensorDataScale value of 'units(9)', an
EntitySensorValue ranging from '0' to '1000', and an
EnergySensorMaxError value of 2000. The EntitySensorValue
would be interpreted as 'degrees C * 10 +/- 0.2 degrees C."
SYNTAX Integer32 (-1000000000..1000000000)
--******************************************************************
-- Top Level Structure of the MIB module
--******************************************************************
energyObjects OBJECT IDENTIFIER ::= { energyMIB 1 }
energyConformance OBJECT IDENTIFIER ::= { energyMIB 2 }
--==================================================================
-- 1. Object Definitions
--==================================================================
--------------------------------------------------------------------
-- 1.1. Energy Consumption Table
--------------------------------------------------------------------
energyConsumpTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnergyConsumpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides inforamtion on the current and
accumulated energy consumption of entities.
This is a sparse augment of the entPhysicalTable.
Entries appear in this table for entities for which their
energy consumption can be reported.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 23]
Internet-Draft Power MIB Modules April 2010
An entry in this table SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed."
::= { energyObjects 1 }
energyConsumpEntry OBJECT-TYPE
SYNTAX EnergyConsumpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information on the energy consumption
of physical entity."
INDEX { entPhysicalIndex } -- SPARSE-AUGMENTS
::= { energyConsumpTable 1 }
EnergyConsumpEntry ::=
SEQUENCE {
energyConsumpSensorOperStatus EntitySensorStatus,
energyConsumpNominalSupplyVoltage Unsigned32,
energyConsumpElectricSupplyType INTEGER,
energyConsumpTotalEnergy EntitySensorValue,
energyConsumpEnergyScale EntitySensorDataScale,
energyConsumpEnergyFractionDigits EntitySensorPrecision,
energyConsumpEnergyMaxError EnergySensorMaxError,
energyConsumpMeasurementMethod INTEGER,
energyConsumpDiscontinuityTime TimeStamp,
energyConsumpPowerScale EntitySensorDataScale,
energyConsumpPowerFractionDigits EntitySensorPrecision,
energyConsumpPowerMaxError EnergySensorMaxError,
energyConsumpPowerSampleInterval Unsigned32,
energyConsumpPowerMaxHistory Unsigned32,
energyConsumpRealPower EntitySensorValue,
energyConsumpPeakRealPower EntitySensorValue,
energyConsumpReactivePower EntitySensorValue,
energyConsumpApparentPower EntitySensorValue,
energyConsumpPhaseAngle EntitySensorValue,
energyConsumpPhaseAngleMaxError EnergySensorMaxError
}
energyConsumpSensorOperStatus OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the operational status of the
sensor that is used for measuring the energy consumption
of the entity indicated by entPhysicalIndex."
::= { energyConsumpEntry 1 }
Quittek, et al. draft-quittek-power-mib-01.txt [Page 24]
Internet-Draft Power MIB Modules April 2010
energyConsumpNominalSupplyVoltage OBJECT-TYPE
SYNTAX Unsigned32
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the nominal voltage of the power
supply of the entity. It is provided in units of
millivolt (mV).
The nominal voltage actual of an entity is assumed to be
fixed, while the actual power supply voltage may vary over
time, for example, caused by changing load conditions.
A value of 0 indicates that the nominal supply voltage
is unknown."
::= { energyConsumpEntry 2 }
energyConsumpElectricSupplyType OBJECT-TYPE
SYNTAX INTEGER {
alternatingCurrent(1),
directCurrent(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of electrical power
supply for the entity. It is used for distinguishing
between alternating current (AC) supply and direct
current (DC) supply."
::= { energyConsumpEntry 3 }
energyConsumpTotalEnergy OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watt hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total consumed energy measured in
watt hours at the electrical power supply of the entity.
Scale and precision of the value are indicated
by objects energyConsumpEnergyScale and
energyConsumpEnergyPrecision.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
Quittek, et al. draft-quittek-power-mib-01.txt [Page 25]
Internet-Draft Power MIB Modules April 2010
times as indicated by the value of
energyConsumpDiscontinuityTime."
::= { energyConsumpEntry 4 }
energyConsumpEnergyScale OBJECT-TYPE
SYNTAX EntitySensorDataScale
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the scale of the values provided
by objects energyConsumpTotalEnergy and
energyConsumpPSTotalEnergy."
::= { energyConsumpEntry 5 }
energyConsumpEnergyFractionDigits OBJECT-TYPE
SYNTAX EntitySensorPrecision
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of decimal places in the
fractional part of the value provided by objects
energyConsumpTotalEnergy and energyConsumpPSTotalEnergy.
This object MUST have a non-negative value. A value of
0 indicates that there is no fractional part."
::= { energyConsumpEntry 6 }
energyConsumpEnergyMaxError OBJECT-TYPE
SYNTAX EnergySensorMaxError
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates maximal error of the measured energy
consumption values provided by objects
energyConsumpTotalEnergy and energyConsumpPSTotalEnergy.
The actual value of the consumed energy may be greater or
less than the reported value with the maximal difference
between actual and reported value indicated by this object.
A value of 0 indicates that the maximum error is unknown."
::= { energyConsumpEntry 7 }
energyConsumpMeasurementMethod OBJECT-TYPE
SYNTAX INTEGER {
directEnergyMeasurement(1),
powerOversampling(2),
powerSampling(3),
Quittek, et al. draft-quittek-power-mib-01.txt [Page 26]
Internet-Draft Power MIB Modules April 2010
loadBasedEstimation(4),
deviceBasedEstimation(5),
unknown(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the method used for measuring energy
consumption. A device may not be equipped with capabilities
to measure its energy consumption directly, but rather relies
on other input in order to conduct more or less precise
estimations of its power consumption.
The measurement methods concerns values of objects
energyConsumpTotalEnergy, energyConsumpPSTotalEnergy,
and energyPowerHistoryAverageValue.
Five different measurement methods are specified.
- directEnergyMeasurement(1) indicates that the entity is
instrumented to directly measure its energy consumption.
- powerOversampling(2) indicates that energy is measured
by sampling power values more frequently than indicated
by the value of object energyConsumpPowerSampleInterval.
- powerSampling(3) indicates that energy is measured
by sampling power values according to the value of object
energyConsumpPowerSampleInterval.
- loadBasedEstimation(4) indicates that power is estimated
based on measurements of the load of the entity.
- deviceBasedEstimation(5) indicates that power is estimated
based on static properties of the entity. In this case,
reported power only depednds on the pwoer state of the
devices as indicated by object powerCurrentState in the
powerCurrentStateTable of the Power State MIB module."
::= { energyConsumpEntry 8 }
energyConsumpDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime on the most recent occasion at which
any one or more of this entity's energy consumption counters
suffered a discontinuity. The relevant counters are
Quittek, et al. draft-quittek-power-mib-01.txt [Page 27]
Internet-Draft Power MIB Modules April 2010
energyConsumpTotalEnergy and energyConsumpPSTotalEnergy. If
no such discontinuities have occurred since the last re-
initialization of the local management subsystem, then this
object contains a zero value."
::= { energyConsumpEntry 9 }
energyConsumpPowerScale OBJECT-TYPE
SYNTAX EntitySensorDataScale
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the scale of the values provided by
objects energyConsumpRealPower, energyConsumpPeakRealPower,
energyConsumpReactivePower, and energyConsumpApparentPower."
::= { energyConsumpEntry 10 }
energyConsumpPowerFractionDigits OBJECT-TYPE
SYNTAX EntitySensorPrecision
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of decimal places in the
fractional part of the value provided by objects
energyConsumpRealPower, energyConsumpPeakRealPower,
energyConsumpReactivePower, and energyConsumpApparentPower.
This object MUST have a non-negative value. A value of
0 indicates that there is no fractional part."
::= { energyConsumpEntry 11 }
energyConsumpPowerMaxError OBJECT-TYPE
SYNTAX EnergySensorMaxError
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates maximal error of the measured
Power values provided by objects energyConsumpRealPower,
energyConsumpPeakRealPower, energyConsumpReactivePower,
and energyConsumpApparentPower.
The actual power value may be greater or less than the
reported value with the maximal difference between actual
and reported value indicated by this object.
A value of 0 indicates that the maximum error is unknown."
::= { energyConsumpEntry 12 }
energyConsumpPowerSampleInterval OBJECT-TYPE
Quittek, et al. draft-quittek-power-mib-01.txt [Page 28]
Internet-Draft Power MIB Modules April 2010
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates is the difference of time
stamps between two consecutive entries in the
energyPowerHistoryTable for this entity.
The interval lenght provided by this object indicates the
or maximum interval length (or minimal samping rate) at which
the power sensor measures values of the current power.
Implementations of the Energy MIB module may choose higher
sampling rates (or shorter sampling intervals) in order to
provide higher precision of the measurement. Preferably,
shorter intervals may be chosen such that the sampling
interval indicated by this object is a multiple of the actual
sampling interval.
The sampling interval is provided in units of microseconds.
A value of 0 indicates that the sampling interval applied by
the sensor is unknown or not constant."
::= { energyConsumpEntry 13 }
energyConsumpPowerMaxHistory OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates is the maximum number of
corresponding entries in the energyPowerHistoryTable.
An entry in the energyPowerHistoryTable is corresponding
if it has the same value for object entPhysicalIndex as
index.
An implementation of the Energy MIB module will remove the
oldest correaponding entry in the energyPowerHistoryTable
to allow the addition of a new entry once the number of
corresponding entries in the energyPowerHistoryTable
reaches this value.
Entries are added to the energyPowerHistoryTable until
energyConsumpPowerMaxHistory is reached before entries
begin to be removed.
A value of 0 for this object disables creation of
corresponding energyPowerHistoryTable entries."
Quittek, et al. draft-quittek-power-mib-01.txt [Page 29]
Internet-Draft Power MIB Modules April 2010
DEFVAL { 0 }
::= { energyConsumpEntry 14 }
energyConsumpRealPower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current real power value
measured in watts at the electrical supply of the entity
indicated by index entPhysicalIndex.
Scale and precision of the value are indicated by objects
energyConsumpPowerScale and energyConsumpPowerPrecision.
Measured values of this object are stored in the
energyPowerHistoryTable with a rate determined by object
energyConsumpPowerSampleInterval."
::= { energyConsumpEntry 15 }
energyConsumpPeakRealPower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the highest observed value for
object energyConsumpRealPower since the last
re-initialization of the management system.
Scale and precision of the value are indicated by objects
energyConsumpPowerScale and energyConsumpPowerPrecision."
::= { energyConsumpEntry 16 }
energyConsumpReactivePower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "volt-amperes reactive"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current reactive power value
measured in volt-amperes reactive (var) at the electrical
supply of the entity for a time interval indicated by object
energyConsumpSampleInterval.
The value provided by this object is only useful if the
value of object energyConsumpSupplyType is
Quittek, et al. draft-quittek-power-mib-01.txt [Page 30]
Internet-Draft Power MIB Modules April 2010
alternatingCurrent(1). In this case it is RECOMMENDED that
at least one of the three values energyConsumpReactivePower,
energyConsumpApparentPowerScale, and energyConsumpPhaseAngle
are provided.
Scale and precision of the value are indicated by objects
energyConsumpPowerScale and energyConsumpPowerPrecision.
If object energyConsumpElectricSupplyType of this row has a
value other than alternatingCurrent(1), then the value of
this object MUST be 0.
If object energyConsumpElectricSupplyType of this row has the
value alternatingCurrent(1) and if no value for the current
reactive power is provided, then the value of this object
MUST be -10000000000000."
::= { energyConsumpEntry 17 }
energyConsumpApparentPower OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "volt-ampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current apparent power value
measured in volt-ampere (VA) at the electrical supply of the
entity for a time interval indicated by object
energyConsumpSampleInterval.
The value provided by this object is only useful if the
value of object energyConsumpSupplyType is
alternatingCurrent(1). In this case it is RECOMMENDED that
at least one of the three values energyConsumpReactivePower,
energyConsumpApparentPowerScale, and energyConsumpPhaseAngle
are provided.
Scale and precision of the value are indicated by objects
energyConsumpPowerScale and energyConsumpPowerPrecision.
If object energyConsumpElectricSupplyType of this row has a
value other than alternatingCurrent(1), then the value of
this object MUST be equal to the value of object
energyConsumpRealPower.
If object energyConsumpElectricSupplyType of this row has the
value alternatingCurrent(1) and if no value for the current
apparent power is provided, then the value of this object
MUST be -10000000000."
Quittek, et al. draft-quittek-power-mib-01.txt [Page 31]
Internet-Draft Power MIB Modules April 2010
::= { energyConsumpEntry 18 }
energyConsumpPhaseAngle OBJECT-TYPE
SYNTAX EntitySensorValue
-- SYNTAX Integer32 (-1000000000..1000000000)
UNITS "millidegrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current phase angle value
measured at the electrical supply of the entity for a time
interval indicated by object energyConsumpSampleInterval.
The value provided by this object is only useful if the
value of object energyConsumpSupplyType is
alternatingCurrent(1). In this case it is RECOMMENDED that
at least one of the three values energyConsumpReactivePower,
energyConsumpApparentPowerScale, and energyConsumpPhaseAngle
are provided.
The value is provided in units of millidegree (one thousands
of a degree. This is equivalent to an assiciated object
of type EntitySensorDataScale with the value of milli(8) and
an associated object of type EntitySensorPrecision with a
value of 0.
The minimum value for this object is -180000, the maximum
value is 180000. Since the scaling factor is constant, there
is no object of type EntitySensorDataScale provided for
object energyConsumpPhaseAngle.
The maximum error of of the value is indicated by object
energyConsumpPhaseAngleMaxError.
If object energyConsumpElectricSupplyType of this row has a
value other than alternatingCurrent(1), then the value of
this object MUST be 0.
If object energyConsumpElectricSupplyType of this row has the
value alternatingCurrent(1) and if no value for the phase
angle is provided, then the value of this object
MUST be -10000000000."
::= { energyConsumpEntry 19 }
energyConsumpPhaseAngleMaxError OBJECT-TYPE
SYNTAX EnergySensorMaxError
UNITS "millidegrees"
MAX-ACCESS read-only
Quittek, et al. draft-quittek-power-mib-01.txt [Page 32]
Internet-Draft Power MIB Modules April 2010
STATUS current
DESCRIPTION
"This object indicates maximal error of the measured
phase angle provided by object energyConsumpPhaseAngle.
The actual phase angle may be greater or less than the
reported value with the maximal difference between actual
and reported value indicated by this object.
A value of 0 indicates that the maximum error is unknown."
::= { energyConsumpEntry 20 }
--------------------------------------------------------------------
-- 1.2. Energy Consumption Per Power State Table
--------------------------------------------------------------------
energyConsumpPSTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnergyConsumpPSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides inforamtion on the accumulated energy
consumption of an entity.
This is a sparse augment of the entPhysicalTable.
Entries appear in this table for entities for which their
energy consumption can be reported per power state.
An entry in this table SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed."
::= { energyObjects 2 }
energyConsumpPSEntry OBJECT-TYPE
SYNTAX EnergyConsumpPSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Energy consumption information per power state
for a physical entity."
INDEX { entPhysicalIndex, powerState }
::= { energyConsumpPSTable 1 }
EnergyConsumpPSEntry ::=
SEQUENCE {
energyConsumpPSTotalEnergy EntitySensorValue
}
Quittek, et al. draft-quittek-power-mib-01.txt [Page 33]
Internet-Draft Power MIB Modules April 2010
energyConsumpPSTotalEnergy OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watt hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total consumed energy measured in
watt hours at the electrical power supply of the entity.
Scale and precision of the value are indicated
by objects energyConsumpEnergyScale and
energyConsumpEnergyPrecision.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of
energyConsumpDiscontinuityTime."
::= { energyConsumpPSEntry 1 }
--------------------------------------------------------------------
-- 1.3. Energy Power History Table
--------------------------------------------------------------------
energyPowerHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnergyPowerHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores results of real power measurements
for multiple entities.
This is a sparse augment of the entPhysicalTable.
Entries appear in this table for entities for which
the current power can be measured.
Creation of entries in this row is controlled indivdually
for each entity by two parameters: energyPowerMaxHistory
and energyPowerSamplingInterval.
The energyPowerSamplingInterval controls the difference
in time between the creation of two consecutive entries
in this table. Object energyPowerMaxHistory limits the
number of entries in this table that can be created for
the corresponding entity.
An implementation of the Energy MIB module will remove the
oldest entry for an entity in the energyPowerHistoryTable
to allow the addition of a new entry once the number of
Quittek, et al. draft-quittek-power-mib-01.txt [Page 34]
Internet-Draft Power MIB Modules April 2010
entries for this entity reaches the value indicated by
object energyPowerMaxHistory.
Entries for a specific entity are added to this table
until energyConsumpPowerMaxHistory is reached before
entries begin to be removed.
Entries for the same entity are indexed by
energyPowerHistoryIndex. The first entry for an entity
MUST have an index value of 1. Further new entries MUST
be indexed by consecutive numbers in the order in which
they are created until the value of
energyConsumpPowerMaxHistory is reached. Then no further
new indices will be assigned, but existing ones will be
re-used.
Entries for a specific entity in this table SHOULD be
destroyed if the corresponding entPhysicalEntry is
destroyed."
::= { energyObjects 3 }
energyPowerHistoryEntry OBJECT-TYPE
SYNTAX EnergyPowerHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry indicating the real power value for an entity
at a certain point in time."
INDEX { entPhysicalIndex, energyPowerHistoryIndex }
::= { energyPowerHistoryTable 1 }
EnergyPowerHistoryEntry ::=
SEQUENCE {
energyPowerHistoryIndex Unsigned32,
energyPowerHistoryTimestamp TimeStamp,
energyPowerHistoryAverageValue EntitySensorValue,
energyPowerHistoryPeakValue EntitySensorValue
}
energyPowerHistoryIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for this entry per entity.
Values of this index MUST be unique per entity used
as first index."
::= { energyPowerHistoryEntry 1 }
Quittek, et al. draft-quittek-power-mib-01.txt [Page 35]
Internet-Draft Power MIB Modules April 2010
energyPowerHistoryTimestamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the end of the measurement interval
for which average and peak power values are provided.
This time MAY be identical with the time at which this
entry was created."
::= { energyPowerHistoryEntry 2 }
energyPowerHistoryAverageValue OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the average real power value
for a time interval measured in watts at the electrical
supply of the entity indicated by the first index of the
entry. The time interval starts with the time stamp of the
previous entry in the time line and ends with the time stamp
of this entry's timestamp value indicated by object
energyPowerHistoryTimestamp.
If there is no previous entry, then the interval
length is given by the value of the correponding object
energyPowerSamplingInterval in the energyConsumpTable.
The measurement of average power can be conducted by
applying different methods. The method used for this
object is indicated by the corresponding object
energyConsumpMeasurementMethod.
If the sensor used for measurements is capable of
directly measuring the total energy consumption in the
time interval between the previous entry in this table
and a new one to be created, then the reported power
value SHOULD be the average power value during that
interval computed by dividing the measured energy
consumption by the length of the time interval.
This case is indicated by the corresponding object
energyConsumpMeasurementMethod having a value of
directEnergyMeasurement(1).
For energy consumption measurement based on power sampling,
there are two alternative cases. If then actual value of
object energyConsumpRealPower is measured more frequently
Quittek, et al. draft-quittek-power-mib-01.txt [Page 36]
Internet-Draft Power MIB Modules April 2010
than required by the value of energyPowerSamplingInterval
(the corresponding object energyConsumpMeasurementMethod
having a value of powerOversampling(2)), then implementations
of the Energy MIB module SHOULD set the value of this object
to an average of all values of object energyConsumpRealPower
that have been measured during the sampling interval.
If no oversampling is performed, i.e. the power is measured
just once per sampling interval, then at the time of its
creation, the value of this object is identical to the value
of the corresponding object energyConsumpRealPower.
This case is indicated by the corresponding object
energyConsumpMeasurementMethod having a value of
powerSampling(3). In this case, the measurement of power
should be conducted at a time that is as close to the value
of energyPowerHistoryTimestamp as possible.
The power may not measured directly, but derived from
measuring the current load of the entity and/or its power
state. These cases are indicated by the corresponding object
energyConsumpMeasurementMethod having a value of
loadBasedEstimation(4) or deviceBasedEstimation(5),
respectively.
Scale and precision of the value are indicated by
corresponding objects energyConsumpPowerScale and
energyConsumpPowerPrecision in the energyConsumpTable."
::= { energyPowerHistoryEntry 3 }
energyPowerHistoryPeakValue OBJECT-TYPE
SYNTAX EntitySensorValue
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the peak real power value
for a time interval measured in watts at the electrical
supply of the entity indicated by the first index of the
entry. The time interval starts with the time stamp of the
previous entry in the time line and ends with the time stamp
of this entry's timestamp value indicated by object
energyPowerHistoryTimestamp.
If there is no previous entry, then the interval
length is given by the vakue of the correponding object
energyPowerSamplingInterval in the energyConsumpTable.
At the time this object is created, its value can be
Quittek, et al. draft-quittek-power-mib-01.txt [Page 37]
Internet-Draft Power MIB Modules April 2010
identical with the value of the corresponding object
energyConsumpRealPower. However, if the actual value of
object energyConsumpRealPower is measured more frequently
than required by the value of energyPowerSamplingInterval,
then implementations of the Energy MIB module SHOULD set
the value of this object to the maximum of all values of
object energyConsumpRealPower that have been measured
during the sampling interval.
Scale and precision of the value are indicated by
corresponding objects energyConsumpPowerScale and
energyConsumpPowerPrecision in the energyConsumpTable."
::= { energyPowerHistoryEntry 4 }
--==================================================================
-- 2. Conformance Information
--==================================================================
energyCompliances OBJECT IDENTIFIER ::= { energyConformance 1 }
energyGroups OBJECT IDENTIFIER ::= { energyConformance 2 }
--------------------------------------------------------------------
-- 2.1. Compliance Statements
--------------------------------------------------------------------
energyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for implementations of the
ENERGY-MIB module.
A compliant implementation MUST implement the objects
defined in the mandatory group energyRequiredGroup.
If one of the entities for which energy consumption is
reported are supplied by alternating current (AC) then it
is recommended that not just real power is reported
(REQUIRED) but it is also RECOMMENDED that at least one
of three other related values (reactive power, apparent
power, and phase angle) is reported by implementing at least
one of the three groups energyReactivePowerGroup,
energyApparentPowerGroup, and energyPhaseAngleGroup."
MODULE -- this module
MANDATORY-GROUPS { energyRequiredGroup }
GROUP energyPowerHistoryGroup
DESCRIPTION
Quittek, et al. draft-quittek-power-mib-01.txt [Page 38]
Internet-Draft Power MIB Modules April 2010
"This group is only needed for implementations that
support storing time series of measured power values
in the energyPowerHistoryTable."
GROUP energyACGroup
DESCRIPTION
"This group is only needed for implementations that report
consumption of electric energy provided by alternating
current (AC) supply.
Implementations for devices supplied with direct current (DC)
only and implementations that do only report real power
reporting for alternative current do not need to implement
objects in this group."
GROUP energyReactivePowerGroup
DESCRIPTION
"Information provided by elements in this group is redundant
to information provided by elements in the
energyApparentPowerGroup and the energyPhaseAngleGroup.
For compliant implementations that report consumption of
electric energy provided by alternating current (AC) supply
it is RECOMMENDED to at least one of the three groups
energyReactivePowerGroup, energyApparentPowerGroup, and
energyPhaseAngleGroup."
GROUP energyApparentPowerGroup
DESCRIPTION
"Information provided by elements in this group is redundant
to information provided by elements in the
energyReactivePowerGroup and the energyPhaseAngleGroup.
For compliant implementations that report consumption of
electric energy provided by alternating current (AC) supply
it is RECOMMENDED to at least one of the three groups
energyReactivePowerGroup, energyApparentPowerGroup, and
energyPhaseAngleGroup."
GROUP energyPhaseAngleGroup
DESCRIPTION
"Information provided by elements in this group is redundant
to information provided by elements in the
energyReactivePowerGroup and the energyApparentPowerGroup.
For compliant implementations that report consumption of
electric energy provided by alternating current (AC) supply
it is RECOMMENDED to at least one of the three groups
Quittek, et al. draft-quittek-power-mib-01.txt [Page 39]
Internet-Draft Power MIB Modules April 2010
energyReactivePowerGroup, energyApparentPowerGroup, and
energyPhaseAngleGroup."
::= { energyCompliances 1 }
--------------------------------------------------------------------
-- 2.2. Object Grouping
--------------------------------------------------------------------
energyRequiredGroup OBJECT-GROUP
OBJECTS {
energyConsumpSensorOperStatus,
energyConsumpNominalSupplyVoltage,
energyConsumpElectricSupplyType,
energyConsumpTotalEnergy,
energyConsumpEnergyScale,
energyConsumpEnergyFractionDigits,
energyConsumpEnergyMaxError,
energyConsumpMeasurementMethod,
energyConsumpDiscontinuityTime,
energyConsumpPowerScale,
energyConsumpPowerFractionDigits,
energyConsumpPowerMaxError,
energyConsumpRealPower,
energyConsumpPeakRealPower,
energyConsumpPSTotalEnergy
}
STATUS current
DESCRIPTION
"A compliant implementation MUST implement the objects
contained in this group."
::= { energyGroups 1 }
energyPowerHistoryGroup OBJECT-GROUP
OBJECTS {
energyConsumpPowerSampleInterval,
energyConsumpPowerMaxHistory,
energyPowerHistoryTimestamp,
energyPowerHistoryAverageValue,
energyPowerHistoryPeakValue
}
STATUS current
DESCRIPTION
"The group of object for reporting details of
AC power measurement."
::= { energyGroups 2 }
energyACGroup OBJECT-GROUP
Quittek, et al. draft-quittek-power-mib-01.txt [Page 40]
Internet-Draft Power MIB Modules April 2010
OBJECTS {
energyConsumpReactivePower,
energyConsumpApparentPower,
energyConsumpPhaseAngle,
energyConsumpPhaseAngleMaxError
}
STATUS current
DESCRIPTION
"The group of object for reporting details of
AC power measurement."
::= { energyGroups 3 }
energyReactivePowerGroup OBJECT-GROUP
OBJECTS {
energyConsumpReactivePower
}
STATUS current
DESCRIPTION
"The group of object for reporting the reactive power
measured for AC supply."
::= { energyGroups 4 }
energyApparentPowerGroup OBJECT-GROUP
OBJECTS {
energyConsumpApparentPower
}
STATUS current
DESCRIPTION
"The group of object for reporting the apparent power
measured for AC supply."
::= { energyGroups 5 }
energyPhaseAngleGroup OBJECT-GROUP
OBJECTS {
energyConsumpPhaseAngle,
energyConsumpPhaseAngleMaxError
}
STATUS current
DESCRIPTION
"The group of object for reporting the phase angler
measured for AC supply."
::= { energyGroups 6 }
END
7.3. Battery MIB
BATTERY-MIB DEFINITIONS ::= BEGIN
Quittek, et al. draft-quittek-power-mib-01.txt [Page 41]
Internet-Draft Power MIB Modules April 2010
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
mib-2, Integer32, Unsigned32, Counter32
FROM SNMPv2-SMI -- RFC2578
DateAndTime
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC2580
entPhysicalIndex
FROM ENTITY-MIB; -- RFC4133
batteryMIB MODULE-IDENTITY
LAST-UPDATED "201001291200Z" -- 29 January 2010
ORGANIZATION "IETF OPSAWG Working Group"
CONTACT-INFO
"General Discussion: opsawg@ietf.org
To Subscribe: https://www.ietf.org/mailman/listinfo/opsawg
Archive: http://www.ietf.org/mail-archive/web/opsawg
Co-editor:
Juergen Quittek
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Tel: +49 6221 4342-115
Email: quittek@neclab.eu
Co-editor:
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-128
Email: Thomas.Dietz@neclab.eu"
DESCRIPTION
"This MIB module defines a set of objects for monitoring
batteries of networked devices and of their components.
Copyright (c) 2010 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
Quittek, et al. draft-quittek-power-mib-01.txt [Page 42]
Internet-Draft Power MIB Modules April 2010
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).
This version of this MIB module is part of RFC yyyy; see
the RFC itself for full legal notices."
-- replace yyyy with actual RFC number & remove this notice
-- Revision history
REVISION "201001291200Z" -- 29 January 2010
DESCRIPTION
"Initial version, published as RFC yyyy."
-- replace yyyy with actual RFC number & remove this notice
::= { mib-2 zzz }
-- zzz to be assigned by IANA.
--******************************************************************
-- Top Level Structure of the MIB module
--******************************************************************
batteryNotifications OBJECT IDENTIFIER ::= { batteryMIB 0 }
batteryObjects OBJECT IDENTIFIER ::= { batteryMIB 1 }
batteryConformance OBJECT IDENTIFIER ::= { batteryMIB 2 }
--==================================================================
-- 1. Object Definitions
--==================================================================
--------------------------------------------------------------------
-- 1.1. Battery Table
--------------------------------------------------------------------
batteryTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides information on batteries in networked
devices. It is designed as a sparse augment of the
entPhysicalTable defined in the ENTITY-MIB module and assumes
that each battery is represented by an individual row in the
entPhysicalTable with an individual value for the index
entPhysicalIndex.
Entries appear in this table only for entities that represent
a battery. An entry in this table SHOULD be created at the
Quittek, et al. draft-quittek-power-mib-01.txt [Page 43]
Internet-Draft Power MIB Modules April 2010
same time as the associated entPhysicalEntry. An entry
SHOULD be destroyed if the associated entPhysicalEntry is
destroyed."
::= { batteryObjects 1 }
batteryEntry OBJECT-TYPE
SYNTAX BatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry providing information on a battery."
INDEX { entPhysicalIndex } -- SPARSE-AUGMENTS
::= { batteryTable 1 }
BatteryEntry ::=
SEQUENCE {
batteryType INTEGER,
batteryTechnology INTEGER,
batteryNominalVoltage Unsigned32,
batteryNumberOfCells Unsigned32,
batteryNominalCapacity Unsigned32,
batteryRemainingCapacity Unsigned32,
batteryChargingCycleCount Counter32,
batteryLastChargingCycleTime DateAndTime,
batteryState INTEGER,
batteryCurrentCharge Unsigned32,
batteryCurrentChargePercentage Unsigned32,
batteryCurrentVoltage Unsigned32,
batteryCurrentCurrent Integer32,
batteryLowAlarmPercentage Unsigned32,
batteryLowAlarmVoltage Unsigned32,
batteryReplacementAlarmCapacity Unsigned32,
batteryReplacementAlarmCycles Unsigned32
}
batteryType OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
rechargeable(2),
capacitor(3),
other(4),
unknown(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of battery. It distinguishes
between one-way primary batteries, rechargeable secondary
Quittek, et al. draft-quittek-power-mib-01.txt [Page 44]
Internet-Draft Power MIB Modules April 2010
batteries and capacitors which are not really batteries but
often used in the same way as a battery.
The value other(4) can be used if the battery type is known
but none of the ones above. Value unknown(5) is to be used
if the type of battery cannot be determined."
::= { batteryEntry 1 }
batteryTechnology OBJECT-TYPE
SYNTAX INTEGER {
zincCarbon(1),
zincChloride(2),
oxyNickelHydroxide(3),
lithiumCopper(4),
lithiumIron(5),
lithiumManganese(6),
zincAir(7),
silverOxide(8),
alcaline(9),
leadAcid(10),
nickelCadmium(12),
nickelMetalHybride(13),
nickelZinc(14),
lithiumIon(15),
lithiumPolymer(16),
doubleLayerCapacitor(17),
other(18),
unknown(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the technology used by the battery.
Values 1-8 are primary battery technologies, values 10-16
are rechargeable battery technologies and value alkaline(9)
is used for primary batteries as well as for rechargeable
batteries.
The value other(18) can be used if the battery type is known
but none of the ones above. Value unknown(19) is to be used
if the type of battery cannot be determined."
::= { batteryEntry 2 }
batteryNominalVoltage OBJECT-TYPE
SYNTAX Unsigned32
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
Quittek, et al. draft-quittek-power-mib-01.txt [Page 45]
Internet-Draft Power MIB Modules April 2010
DESCRIPTION
"This object provides the nominal voltage of the battery
in units of millivolt (mV).
Note that the nominal voltage is a constant value and
typically different from the actual voltage of the battery.
A value of 0 indicates that the nominal voltage is unknown."
::= { batteryEntry 3 }
batteryNumberOfCells OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of cells contained in the
battery.
A value of 0 indicates that the number of cells is unknown."
::= { batteryEntry 4 }
batteryNominalCapacity OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliampere hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the nominal capacity of the battery
in units of milliampere hours (mAh).
Note that the nominal capacity is a constant value and
typically different from the actual capacity of the battery.
A value of 0 indicates that the nominal capacity is unknown."
::= { batteryEntry 5 }
batteryRemainingCapacity OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliampere hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the ACTUAL REMAINING capacity of the
battery in units of milliampere hours (mAh).
Note that the actual capacity needs to be measured and is
typically an estimate based on observed discharging and
charging cycles of the battery.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 46]
Internet-Draft Power MIB Modules April 2010
A value of 'ffffffff'H indicates that the actual capacity
cannot be determined."
::= { batteryEntry 6 }
batteryChargingCycleCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of charging cycles that
that the battery underwent. Please note that the precise
definition of a rechsarge cycle varies for different kinds
of batteries and of devices containing batteries.
For batteries of type primary(1) the value of this object is
always 0.
A value of 'ffffffff'H indicates that the number of charging
cycles cannot be determined."
::= { batteryEntry 7 }
batteryLastChargingCycleTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time of the last charging cycle. The value
'0000000000000000'H is returned if the battery has not been
charged yet or if the last charging time cannot be
determined.
For batteries of type primary(1) the value of this object is
always '0000000000000000'H."
::= { batteryEntry 8 }
batteryState OBJECT-TYPE
SYNTAX INTEGER {
full(1),
partiallyCharged(2),
empty(3),
charging(4),
discharging(5),
unknown(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current state of the battery.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 47]
Internet-Draft Power MIB Modules April 2010
Value full(1) indicates a full battery with a capacity
given by onject batteryRemainingCapacity. Value empty(3)
indicates a battery that cannot be used for providing
electric power before charging it. Value partiallyCharged(2)
is provided if the battery is neither empty nor full and if
no charging or discharging is in progress. Charging or
discharging of hte battery is indicated by values charging(3)
or discharging(4), respectively.
Value unknown(6) is to be used if the state of the battery
cannot be determined."
::= { batteryEntry 9 }
batteryCurrentCharge OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliampere hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the current charge of the battery
in units of milliampere hours (mAh).
Note that the current charge needs to be measured and is
typically an estimate based on observed discharging and
charging cycles of the battery.
A value of 'ffffffff'H indicates that the current charge
cannot be determined."
::= { batteryEntry 10 }
batteryCurrentChargePercentage OBJECT-TYPE
SYNTAX Unsigned32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the current charge of the battery
relative to the nominal capacity in units of a hundreds
of a percent.
--------------------------
-- Open issue:
-- Should it be the percentage of the nominal capacity
-- or of the current capacity?
--------------------------
Note that this value needs to be measured and is
typically an estimate based on observed discharging and
charging cycles of the battery.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 48]
Internet-Draft Power MIB Modules April 2010
A value of 'ffffffff'H indicates that the relative current
charge cannot be determined."
::= { batteryEntry 11 }
batteryCurrentVoltage OBJECT-TYPE
SYNTAX Unsigned32
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the current voltage of the battery
in units of millivolt (mV).
A value of 'ffffffff'H indicates that the current voltage
cannot be determined."
::= { batteryEntry 12 }
batteryCurrentCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "milliampere"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the current charging or discharging
current of the batteryin units of milliampere (mA). Charging
current is indicated by positive values, discharging current
is indicated by negative values.
A value of '7fffffff'H indicates that the current current
cannot be determined."
::= { batteryEntry 13 }
batteryLowAlarmPercentage OBJECT-TYPE
SYNTAX Unsigned32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the lower threshold value for object
batteryCurrentChargePercentage. If the value of object
batteryCurrentChargePercentage falls below this threshold,
a low battery alarm will be raised. The alarm procedure may
include generating a batteryLowNotification.
A value of 0 indicates that the no alarm will be raised for
any value of object batteryCurrentChargePercentage."
::= { batteryEntry 14 }
batteryLowAlarmVoltage OBJECT-TYPE
Quittek, et al. draft-quittek-power-mib-01.txt [Page 49]
Internet-Draft Power MIB Modules April 2010
SYNTAX Unsigned32
UNITS "millivolt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the lower threshold value for object
batteryCurrentVoltage. If the value of object
batteryCurrentVoltage falls below this threshold,
a low battery alarm will be raised. The alarm procedure may
include generating a batteryLowNotification.
A value of 0 indicates that the no alarm will be raised for
any value of object batteryCurrentVoltage."
::= { batteryEntry 15 }
batteryReplacementAlarmCapacity OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliampere hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the lower threshold value for object
batteryRemainingCapacity. If the value of object
batteryRemainingCapacity falls below this threshold,
a battery aging alarm will be raised. The alarm procedure
may include generating a batteryAgingNotification.
A value of 0 indicates that the no alarm will be raised for
any value of object batteryRemainingCapacity."
::= { batteryEntry 16 }
batteryReplacementAlarmCycles OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliampere hours"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the upper threshold value for object
batteryChargingCycleCount. If the value of object
batteryChargingCycleCount rises above this threshold,
a battery aging alarm will be raised. The alarm procedure
may include generating a batteryAgingtNotification.
A value of 0 indicates that the no alarm will be raised for
any value of object batteryChargingCycleCount."
::= { batteryEntry 17 }
Quittek, et al. draft-quittek-power-mib-01.txt [Page 50]
Internet-Draft Power MIB Modules April 2010
--==================================================================
-- 2. Notifications
--==================================================================
batteryLowNotification NOTIFICATION-TYPE
OBJECTS {
batteryCurrentChargePercentage,
batteryCurrentVoltage
}
STATUS current
DESCRIPTION
"This notification can be generated when the current charge
(batteryCurrentChargePercentage) or the current voltage
(batteryCurrentVoltage) of the battery falls below a
threshold defined by object batteryLowAlarmPercentage or
object batteryLowAlarmVoltage, respectively."
::= { batteryNotifications 1 }
batteryAgingNotification NOTIFICATION-TYPE
OBJECTS {
batteryRemainingCapacity,
batteryChargingCycleCount
}
STATUS current
DESCRIPTION
"This notification can be generated when the remaining
capacity (batteryRemainingCapacity) falls below a threshold
defined by object batteryReplacementAlarmCapacity
or when the charging cycle count of the battery
(batteryChargingCycleCount) exceeds the threshold defined
by object batteryLowAlarmPercentage."
::= { batteryNotifications 2 }
--==================================================================
-- 3. Conformance Information
--==================================================================
batteryCompliances OBJECT IDENTIFIER ::= { batteryConformance 1 }
batteryGroups OBJECT IDENTIFIER ::= { batteryConformance 2 }
--------------------------------------------------------------------
-- 3.1. Compliance Statements
--------------------------------------------------------------------
batteryCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
Quittek, et al. draft-quittek-power-mib-01.txt [Page 51]
Internet-Draft Power MIB Modules April 2010
"The compliance statement for implementations of the
POWER-STATE-MIB module.
A compliant implementation MUST implement the objects
defined in the mandatory group psmRequiredGroup."
MODULE -- this module
MANDATORY-GROUPS {
batteryDescriptionGroup,
batteryStatusGroup,
batteryAlarmThresholdsGroup
}
GROUP batteryNotificationsGroup
DESCRIPTION
"A compliant implementation does not have to implement
the psmNotificationsGroup."
::= { batteryCompliances 1 }
--------------------------------------------------------------------
-- 3.2. MIB Grouping
--------------------------------------------------------------------
batteryDescriptionGroup OBJECT-GROUP
OBJECTS {
batteryType,
batteryTechnology,
batteryNominalVoltage,
batteryNumberOfCells,
batteryNominalCapacity
}
STATUS current
DESCRIPTION
"A compliant implementation MUST implement the objects
contained in this group."
::= { batteryGroups 1 }
batteryStatusGroup OBJECT-GROUP
OBJECTS {
batteryRemainingCapacity,
batteryChargingCycleCount,
batteryLastChargingCycleTime,
batteryState,
batteryCurrentCharge,
batteryCurrentChargePercentage,
batteryCurrentVoltage,
batteryCurrentCurrent
}
STATUS current
DESCRIPTION
Quittek, et al. draft-quittek-power-mib-01.txt [Page 52]
Internet-Draft Power MIB Modules April 2010
"A compliant implementation MUST implement the objects
contained in this group."
::= { batteryGroups 2 }
batteryAlarmThresholdsGroup OBJECT-GROUP
OBJECTS {
batteryLowAlarmPercentage,
batteryLowAlarmVoltage,
batteryReplacementAlarmCapacity,
batteryReplacementAlarmCycles
}
STATUS current
DESCRIPTION
"A compliant implementation MUST implement the objects
contained in this group."
::= { batteryGroups 3 }
batteryNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
batteryLowNotification,
batteryAgingNotification
}
STATUS current
DESCRIPTION
"A compliant implementation does not have to implement the
notification contained in this group."
::= { batteryGroups 4 }
END
8. Security Considerations
There are no management objects defined in this MIB module that have
a MAX-ACCESS clause of read-write and/or read-create. So, if this
MIB module is implemented correctly, then there is no risk that an
intruder can alter or create any management objects of this MIB
module via direct SNMP SET operations.
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. These are the tables and objects and their
sensitivity/vulnerability:
Quittek, et al. draft-quittek-power-mib-01.txt [Page 53]
Internet-Draft Power MIB Modules April 2010
o This list is still to be done.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
including full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
9. IANA Considerations
The MIB modules in this document uses the following IANA-assigned
OBJECT IDENTIFIER values recorded in the SMI Numbers registry:
Descriptor OBJECT IDENTIFIER value
---------- -----------------------
powerStateMIB { mib-2 xxx }
energyMIB { mib-2 yyy }
batteryMIB { mib-2 zzz }
Other than that this document does not impose any IANA
considerations.
10. References
10.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 54]
Internet-Draft Power MIB Modules April 2010
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2",
STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC4268] Chisholm, S. and D. Perkins, "Entity State MIB", RFC 4268,
November 2005.
[RFC3621] Berger, A. and D. Romascanu, "Power Ethernet MIB",
RFC 3621, December 2003.
[RFC3433] Bierman, A., Romascanu, D., and K. Norseth, "Entity Sensor
Management Information Base", RFC 3433, December 2002.
[RFC4133] Bierman, A. and K. McCloghrie, "Entity MIB (Version 3)",
RFC 4133, August 2005.
[I-D.quittek-power-monitoring-requirements]
Quittek, J., Winter, R., Dietz, T., Claise, B., and M.
Chandramouli, "Requirements for Power Monitoring",
draft-quittek-power-monitoring-requirements-00 (work in
progress), October 2009.
[I-D.claise-energy-monitoring-mib]
Chandramouli, M., Parello, J., and B. Schoening, "Energy
Monitoring MIB", draft-claise-energy-monitoring-mib-02
(work in progress), March 2010.
10.2. Informative References
[RFC1628] Case, J., "UPS Management Information Base", RFC 1628,
May 1994.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
Quittek, et al. draft-quittek-power-mib-01.txt [Page 55]
Internet-Draft Power MIB Modules April 2010
Authors' Addresses
Juergen Quittek (editor)
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-115
Email: quittek@nw.neclab.eu
Rolf Winter
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-121
Email: Rolf.Winter@nw.neclab.eu
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-128
Email: Thomas.Dietz@nw.neclab.eu
Quittek, et al. draft-quittek-power-mib-01.txt [Page 56]
Internet-Draft Power MIB Modules April 2010
Dominique Dudkowski
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-233
Email: Dominique.Dudkowski@nw.neclab.eu
Quittek, et al. draft-quittek-power-mib-01.txt [Page 57]