One document matched: draft-ietf-ipfc-fcmgmt-int-mib-01.txt
Differences from draft-ietf-ipfc-fcmgmt-int-mib-00.txt
INTERNET-DRAFT FC Mgmt Integration MIB Sept 14, 1999
<draft-ietf-ipfc-fcmgmt-int-mib-01.txt> S. Blumenau
(expires March 14, 2000) (EMC Corporation)
Fibre Channel Management Framework Integration MIB
Status of this Memo:
This document is an Internet-Draft and is in full conformance with
all provisions of Section 10 of RFC2026.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as
Internet-Drafts.
Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other documents
at any time. It is inappropriate to use Internet-Drafts as
reference material or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
Abstract:
The goal of this document is to fill in missing pieces necessary
to enable an enterprise class storage network. One of the more
important features of an enterprise class storage network is
management; this document gives a framework MIB that will provide
an integrated management environment for the enterprise customer.
An enterprise class storage network is comprised of elements
(i.e., hubs, switches, converters, gateways, and HBAs) that are
developed by many different vendors. The large number of vendors
that can exist in a storage network makes mangement a very hard
and complicated problem. The main goal of this document's MIB is
to enable interoperability among the various vendors involved in
the Fibre Channel marketplace.
Acknowledgements:
The following companies have contributed to the creation of this
specification:
o Ancor Communications
o ATTO Technology, Inc.
o Crossroads Systems, Inc.
o EMC Corporation
o Emulex Corporation
Blumenau [Page 01]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
o G2 Networks
o Gadzoox Networks, Inc.
o Hewlett Packard Co.
o Interphase Corporation
o Jaycor Networks Inc.
o Legato Systems, Inc.
o McData Corporation
o Prisa Networks, Inc.
o QLogic Corporation
o Siemens AG
o Sterling Software, Inc.
o Storage Networking Industry Association
o StorageNetworks, Inc.
o Transoft Networks, Inc.
o VERITAS Software Corporation
o Vixel Corporation
The MIB:
FCMGMT-MIB
-- Last edit date: Sep 12th, 1999
DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, TimeTicks, experimental
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
FcNameId ::= OCTET STRING (SIZE(8))
FcGlobalId ::= OCTET STRING (SIZE(16))
fcmgmt OBJECT IDENTIFIER ::= { experimental 94 }
-- groups in fcmgmt
connSet OBJECT IDENTIFIER ::= { fcmgmt 1 }
trapReg OBJECT IDENTIFIER ::= { fcmgmt 2 }
revisionNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the revision number for this MIB. The
format of the revision value is as follows
(0) = high order major revision number
(1) = low order major revision number
(2) = high order minor revision number
(3) = low order minor revision number
The value will be stored as an ASCII value. The
Blumenau [Page 02]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
/conn?U following is the current values.
(0) = '0'
(1) = '2'
(2) = '0'
(3) = '0'
This defines a revision of 2.0
"
::= { fcmgmt 3 }
-- the connectivity unit group
-- Implementation of the group is mandatory for all systems.
uNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connectivity units present on this
system. This is used to identify the number of
boards in a chassis or the number of full boxes
in a rack."
DEFVAL { 1 }
::= { connSet 1 }
systemURL OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The top-level URL of the system. If it does not exist
the value is empty string. The URL format will be
defined by designer and can have keywords embedded
that are preceeded by a percent sign (eg, %USER).
The following are the defined keywords that will
be recognized and replaced with data during a launch.
USER - replace with username
PASSWORD - replace with password
GLOBALID - replace with globalid
SERIALNO - replace with serial number
"
DEFVAL { "" }
::= { connSet 2 }
statusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitStatusChangeTime."
::= { connSet 3 }
Blumenau [Page 03]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
configurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitConfigurationChangeTime."
::= { connSet 4 }
connUnitTableChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the connUnitTable was updated (an entry was either
added or deleted."
::= { connSet 5 }
revsChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last connUnitRevs Table was updated. This
represents a union of change information for
connUnitRevsChangeTime."
::= { connSet 6 }
sensorStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitSensorStatusChangeTime."
::= { connSet 7 }
sensorConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitSensorConfigurationChangeTime."
::= { connSet 8 }
Blumenau [Page 04]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
zoneStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitZoneStatusChangeTime."
::= { connSet 9 }
zoneConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitZoneConfigurationChangeTime."
::= { connSet 10 }
portStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitPortStatusChangeTime."
::= { connSet 11 }
portConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitPortConfigurationChangeTime."
::= { connSet 12 }
linkStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last status change occurred for any members of
the set. This represents a union of change
information for connUnitLinkStatusChangeTime."
::= { connSet 13 }
Blumenau [Page 05]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
linkConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for connUnitLinkConfigurationChangeTime."
::= { connSet 14 }
trapRegConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds at which
the last configuration change occurred for any
members of the set. This represents a union of change
information for trapRegConfigurationChangeTime."
::= { connSet 15 }
-- The Connectivity table contains general information on the
-- system's units.
connUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of units under a single SNMP agent. The number
of entries is given by the value of uNumber. It is 1
for stand-alone system."
::= { connSet 16 }
connUnitEntry OBJECT-TYPE
SYNTAX ConnUnitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A connectivity unit entry containing objects for a
particular unit."
INDEX { connUnitId }
::= { connUnitTable 1 }
ConnUnitEntry ::=
SEQUENCE {
connUnitId
OCTET STRING,
connUnitGlobalId
FcGlobalId,
connUnitType
INTEGER,
connUnitNumports
INTEGER,
connUnitState
INTEGER,
Blumenau [Page 06]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitStatus
INTEGER,
connUnitProduct
DisplayString,
connUnitSn
DisplayString,
connUnitUpTime
TimeTicks,
connUnitUrl
DisplayString,
connUnitDomainId
OCTET STRING,
connUnitProxyMaster
INTEGER,
connUnitPrincipal
INTEGER,
connUnitNumSensors
INTEGER,
connUnitStatusChangeTime
TimeTicks,
connUnitConfigurationChangeTime
TimeTicks,
connUnitNumRevs
INTEGER,
connUnitNumZones
INTEGER,
connUnitModuleId
OCTET STRING,
connUnitName
DisplayString,
connUnitInfo
DisplayString,
connUnitControl
INTEGER,
connUnitContact
DisplayString,
connUnitLocation
DisplayString,
connUnitEventFilter
INTEGER,
connUnitNumEvents
INTEGER,
connUnitEventSize
INTEGER,
connUnitEventCurrID
INTEGER,
connUnitMaxLinks
INTEGER
}
Blumenau [Page 07]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The goal is to create a locally unique Id
space for all connUnitIds within this proxy
domain. It is left up to the vendor to
generate the unique IDs. It is a goal that
the value is kept constant between boots.
It is also a goal that the relationship
be retained between the connUnitId and the
connUnitGlobalId if the connUnitGlobalId is
non-zero."
::= { connUnitEntry 1 }
connUnitGlobalId OBJECT-TYPE
SYNTAX FcGlobalId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The goal is to create a globally unique Id
space for all connUnitGlobalIds within a single
connectivity space (fabric, loop, etc) or even
across multiple connectivity spaces. This is a
set of hex bytes, not ASCII.
connUnitGlobalId is a
WWN, including the leading NAA, in any FC-PH
authorized format. This requires that one would
have to have an IEEE OUI (vendor id) to assign
connUnitGlobalId. Once one has supplied the
NAA and OUI, the vendors are completely
free as to how one assigns the rest of the bits,
as long as you assure they are unique. There
is some merit, though not a requirement, that
the WWN used as connUnitGlobalId be the same
as that of (one of) the permanently attached
FC/LAN interface(s). Whether it is or not,
it must be unique. As an example, if your
agent runs in a host and the host has an HBA,
it is quite possible that agent, host, and HBA
will all be distinct connUnits, so the host
and agent can not use the WWN of the HBA.
Another example:
If your hub has a built-in Ethernet port, it
might be reasonable for the hub to use its LAN
address (prefixed with the with appropriate
NAA) as its connUnitGlobalId. But if the
Ethernet was a replaceable PCCard, the hub
should have an independent ID. If the global
ID is not known then this object is set to
all zeros. When this value is found by a
management station, it will indicate that
information about it should not be trusted
Blumenau [Page 08]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
to be correct. The following are some
references for more information.
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html"
::= { connUnitEntry 2 }
connUnitType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2), -- none of the following
hub(3), -- passive connectivity unit
-- supporting loop protocol.
switch(4), -- active connectivity unit
-- supporting multiple protocols.
gateway(5), -- unit that converts not only
-- the interface but also encapsulates
-- the frame into another protocol. The
-- assumption is that there is always
-- two gateways connected together. For
-- example, FC <-> ATM.
converter(6), -- unit that converts from one
-- interface to another. For
-- example, FC <-> SCSI.
hba(7), -- host bus adapter
proxy-agent(8), -- software proxy-agent
storage-device(9), -- disk,cd,tape,etc
host(10), -- host computer
storage-subsystem(11), -- raid, library, etc
module(12), -- subcomponent of a system
swdriver(13), -- software driver
storage-access-device(14) -- TBD, awaiting definition
-- from STK
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the FC connectivity unit that can be
registered in the MIB."
::= { connUnitEntry 3 }
connUnitNumports OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of physical ports in the unit
(internal/embedded, external)."
::= { connUnitEntry 4 }
Blumenau [Page 09]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitUrl OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"URL to launch management application,
if applicable. Otherwise empty string.
In a standalone unit, this would be the
same as the top-level URL."
::= { connUnitEntry 10 }
connUnitDomainId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24 bit Fibre Channel address ID, right justified
with leading zero's if required. If this value
is not applicable, return all bits set to one."
::= { connUnitEntry 11 }
connUnitProxyMaster OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
no(2),
yes(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a yes if this is the proxy master
unit for a set of managed units. For example,
this could be the only unit with a management
card in it for a set of units. If this is a
standalone unit, then this is set to 'yes'."
::= { connUnitEntry 12 }
connUnitPrincipal OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
no(2),
yes(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Whether the unit is the principal unit
within the group of fabric elements. If this value
is not applicable, return unknown."
::= { connUnitEntry 13 }
Blumenau [Page 10]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitNumSensors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of sensors in the unit."
::= { connUnitEntry 14 }
connUnitStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last status change occurred."
::= { connUnitEntry 15 }
connUnitConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last configuration change
occurred."
::= { connUnitEntry 16 }
connUnitNumRevs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of revisions in the revision
table."
DEFVAL { 1 }
::= { connUnitEntry 17 }
connUnitNumZones OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of zones defined in the zone table."
::= { connUnitEntry 18 }
connUnitModuleId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a unique id that does not need to
be persistent between boots. It is used
to group a set of modules together into
a single connUnit. The intended use would
Blumenau [Page 11]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
be to create a connUnit with a type of
module and then set its moduleid to its
connUnitId. All other connUnits that are
part of the module will have the same
module id as the container. This should
be 16 zeros if it is not used."
::= { connUnitEntry 19 }
connUnitName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..79))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A display string containing a name for this
unit. This item should be persistent across
coldstarts."
::= { connUnitEntry 20 }
connUnitInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A display string containing comments such
as comments on this unit. This item should be
persistent across coldstarts."
::= { connUnitEntry 21 }
connUnitControl OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
invalid(2),
resetConnUnitColdStart(3),
resetConnUnitWarmStart(4),
offlineConnUnit(5),
onlineConnUnit(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to control the addressed
connUnit. Note, 'Cold Start' and 'Warm Start'
are as defined in MIB II and are not ment
to be a factory reset.
Valid commands are:
resetConnUnitColdStart: If the addressed
connUnit allows this operation to be performed
to this MIB object, the addressed unit performs
a 'Cold Start' reset.
Blumenau [Page 12]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
resetConnUnitWarmStart: If the addressed
connUnit allows this operation to be performed
to this MIB object, the addressed unit performs
a 'Warm Start' reset.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
offlineConnUnit: If the addressed connUnit
allows this operation to be performed to this
MIB object, the addressed unit puts itself into
a vendor-specific 'offline' state. In general,
if a unit is in an offline state, it cannot be
used to perform meaningful Fibre Channel work.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
onlineConnUnit: If the addressed connUnit
allows this operation to be performed to this
MIB object, the addressed unit puts itself into
a vendor-specific 'online' state. In general,
if a unit is in an online state, it is capable
of performing meaningful Fibre Channel work.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
For any other value set to this object, the
addressed unit sends back a 'bad value' SNMP
response to the SNMP set request."
::= { connUnitEntry 22 }
connUnitContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object behaves
in a similar manner to the MIB2 'sysContact'
object. If the size of the octet string is
larger than the addressed connUnit can support,
Blumenau [Page 13]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
the addressed unit sends back a 'tooBig' SNMP
response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back
a 'generic error' SNMP response to the SNMP
set request. The addressed unit may also return
a null string in response to an SNMP get
request for this object."
::= { connUnitEntry 23 }
connUnitLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object behaves
in a similar manner to the MIB2 'sysLocation'
object. If the size of the octet string is
larger than the addressed connUnit can support,
the addressed unit sends back a 'tooBig' SNMP
response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back a
'generic error' SNMP response to the SNMP
set request. The addressed unit may also
return a null string in response to an SNMP
get request for this object."
::= { connUnitEntry 24 }
connUnitEventFilter OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value defines the event severity
that will be generated. It records all
events that are greater than or equal to
the value that is set."
::= { connUnitEntry 25 }
Blumenau [Page 14]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitNumEvents OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of events currently defined in
the event table."
::= { connUnitEntry 26 }
connUnitEventSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max number of events that can be defined
in the event table."
::= { connUnitEntry 27 }
connUnitEventCurrID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last used event id (connUnitEventId)."
::= { connUnitEntry 28 }
connUnitMaxLinks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum size of the link table."
::= { connUnitEntry 29 }
-- The Table of revisions for hardware and software elements.
-- Note, there is no status change time object for this table
connUnitRevsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitRevsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the revisions supported by the system."
::= { connSet 17 }
connUnitRevsEntry OBJECT-TYPE
SYNTAX ConnUnitRevsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { connUnitRevsUnitId,
connUnitRevsIndex }
::= { connUnitRevsTable 1 }
Blumenau [Page 15]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
ConnUnitRevsEntry ::=
SEQUENCE {
connUnitRevsUnitId
OCTET STRING,
connUnitRevsIndex
INTEGER,
connUnitRevsRevId
DisplayString,
connUnitRevsDescription
DisplayString }
connUnitRevsUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitRevsEntry 1 }
connUnitRevsIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value among all connUnitRevsEntrys
with the same value of connUnitRevsUnitId,
in the range between 1 and
connUnitNumRevs[connUnitRevsUnitId]."
::= { connUnitRevsEntry 2 }
connUnitRevsRevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A vendor-specific string identifying a
revision of a component of the connUnit
indexed by connUnitRevsUnitId."
::= { connUnitRevsEntry 3 }
connUnitRevsDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of a component to which the revision
corresponds."
::= { connUnitRevsEntry 4 }
Blumenau [Page 16]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
-- The Sensor table
connUnitSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Description of each Sensor for a specific
connUnit."
::= { connSet 18 }
connUnitSensorEntry OBJECT-TYPE
SYNTAX ConnUnitSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific Sensor."
INDEX { connUnitSensorUnitId,
connUnitSensorIndex }
::= { connUnitSensorTable 1 }
ConnUnitSensorEntry ::=
SEQUENCE {
connUnitSensorUnitId
OCTET STRING,
connUnitSensorIndex
INTEGER (1..2147483647),
connUnitSensorName
DisplayString,
connUnitSensorStatus
INTEGER,
connUnitSensorInfo
DisplayString,
connUnitSensorMessage
DisplayString,
connUnitSensorType
INTEGER,
connUnitSensorCharacteristic
INTEGER,
connUnitSensorStatusChangeTime
TimeTicks,
connUnitSensorConfigurationChangeTime
TimeTicks
}
connUnitSensorUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitSensorEntry 1 }
Blumenau [Page 17]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitSensorIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value among all connUnitSensorEntrys
with the same value of connUnitSensorUnitId,
in the range between 1 and
connUnitNumSensor[connUnitSensorUnitId]."
::= { connUnitSensorEntry 2}
connUnitSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes a sensor in the unit."
::= { connUnitSensorEntry 3 }
connUnitSensorStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), -- the sensor is ok
warning(3), -- the sensor has a warning
failed(4) -- the sensor has failed
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status for the sensor."
::= { connUnitSensorEntry 4 }
connUnitSensorInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes miscellaneous info about the sensor
such as its serial number."
::= { connUnitSensorEntry 5 }
connUnitSensorMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes the status of the sensor
as a message. It may also provide more
resolution on the sensor indication, for
example 'Cover temperature 1503K, above
nomimal operating range'"
::= { connUnitSensorEntry 6 }
Blumenau [Page 18]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitSensorType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
battery(3),
fan(4),
power-supply(5),
transmitter(6),
enclosure(7),
board(8),
receiver(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of component being monitored by this
sensor."
::= { connUnitSensorEntry 7 }
connUnitSensorCharacteristic OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
temperature(3),
pressure(4),
emf(5),
currentValue(6), -- current is a keyword
airflow(7),
frequency(8),
power(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The characteristics being monitored by this
sensor."
::= { connUnitSensorEntry 8 }
connUnitSensorStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last status change occurred."
::= { connUnitSensorEntry 9 }
connUnitSensorConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last configuration change occurred."
::= { connUnitSensorEntry 10 }
Blumenau [Page 19]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
-- The Zone table (still under discussion)
connUnitZoneTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitZoneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Description of each Zone for a specific
connUnit."
::= { connSet 19 }
connUnitZoneEntry OBJECT-TYPE
SYNTAX ConnUnitZoneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific Zone."
INDEX { connUnitZoneUnitId,
connUnitZoneIndex,
connUnitZoneMemberIndex }
::= { connUnitZoneTable 1 }
ConnUnitZoneEntry ::=
SEQUENCE {
connUnitZoneUnitId
OCTET STRING,
connUnitZoneIndex
INTEGER (1..2147483647),
connUnitZoneMemberIndex
INTEGER (1..2147483647),
connUnitZoneNumMember
INTEGER,
connUnitZoneName
DisplayString,
connUnitZoneStatus
INTEGER,
connUnitZoneStatusChangeTime
TimeTicks,
connUnitZoneConfigurationChangeTime
TimeTicks
}
connUnitZoneUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitZoneEntry 1 }
Blumenau [Page 20]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitZoneIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each zone. Its value
ranges between 1 and the value of
connUnitNumZones."
::= { connUnitZoneEntry 2}
connUnitZoneMemberIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each member of a zone.
Its value ranges between 1 and the value of
connUnitZoneNumMember."
::= { connUnitZoneEntry 3}
connUnitZoneNumMember OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of members in this zone."
::= { connUnitZoneEntry 4}
connUnitZoneName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes a zone in the unit."
::= { connUnitZoneEntry 5 }
connUnitZoneStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
warning(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the status for the zone."
::= { connUnitZoneEntry 6 }
connUnitZoneStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
Blumenau [Page 21]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
"The sysuptime timestamp in centiseconds
at which the last status change occurred."
::= { connUnitZoneEntry 7 }
connUnitZoneConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last configuration change occurred."
::= { connUnitZoneEntry 8 }
-- The port table
connUnitPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Generic information on ports for a specific
connUnit."
::= { connSet 20 }
connUnitPortEntry OBJECT-TYPE
SYNTAX ConnUnitPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for
a specific port. The entry corresponds to
the connectivity unit index by connUnitId."
INDEX { connUnitPortUnitId,
connUnitPortIndex }
::= { connUnitPortTable 1 }
ConnUnitPortEntry ::=
SEQUENCE {
connUnitPortUnitId
OCTET STRING,
connUnitPortIndex
INTEGER,
connUnitPortType
INTEGER,
connUnitPortFCClassCap
OCTET STRING,
connUnitPortFCClassOp
OCTET STRING,
connUnitPortState
INTEGER,
connUnitPortStatus
INTEGER,
Blumenau [Page 22]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitPortTransmitterType
INTEGER,
connUnitPortModuleType
INTEGER,
connUnitPortWwn
FcNameId,
connUnitPortFCId
OCTET STRING,
connUnitPortCountWarning
OCTET STRING,
connUnitPortCountFailure
OCTET STRING,
connUnitPortCountLinkdown
OCTET STRING,
connUnitPortCountAvgSize
OCTET STRING,
connUnitPortCountAvgRate
OCTET STRING,
connUnitPortSn
DisplayString,
connUnitPortRevision
DisplayString,
connUnitPortVendor
DisplayString,
connUnitPortSpeed
INTEGER,
connUnitPortControl
INTEGER,
connUnitPortName
OCTET STRING,
connUnitPortStatusChangeTime
TimeTicks,
connUnitPortConfigurationChangeTime
TimeTicks,
connUnitPortPhysicalNumber
INTEGER
}
connUnitPortUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitPortEntry 1 }
connUnitPortIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value among all connUnitPortEntrys
with the same value of connUnitPortUnitId,
Blumenau [Page 23]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
in the range between 1 and
connUnitNumPort[connUnitPortUnitId]."
::= { connUnitPortEntry 2 }
connUnitPortType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
not-present(3),
hub-port(4),
n-port(5), -- end port for fabric
l-port(6), -- end port for loop
fl-port(7), -- public loop
f-port(8), -- fabric port
e-port(9), -- fabric expansion port
g-port(10), -- generic fabric port
domain-ctl(11), -- domain controller
hub-controller(12),
scsi(13), -- parallel SCSI port
escon(14),
lan(15),
wan(16)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of the port type."
::= { connUnitPortEntry 3 }
connUnitPortFCClassCap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit mask that specifies the classes
of service capabilities. If this is not
applicable, return all bits set to zero.
The bits are set right justified and have
the following definition:
unknown - 0
class-f - 1
class-one - 2
class-two - 4
class-three - 8
class-four - 16
class-five - 32
class-six - 64"
::= { connUnitPortEntry 4 }
connUnitPortFCClassOp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
Blumenau [Page 24]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
"Bit mask that specifies the classes
of service that are currently operational.
If this is not applicable, return all bits
set to zero. The bits are set right-
justified and have the following definition:
unknown - 0
class-f - 1
class-one - 2
class-two - 4
class-three - 8
class-four - 16
class-five - 32
class-six - 64"
::= { connUnitPortEntry 5 }
connUnitPortState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
online(2),
offline(3),
bypassed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This represents the state of the port
protocol."
::= { connUnitPortEntry 6 }
connUnitPortStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
unused(2),
ok(3),
warning(4), -- needs attention
failure(5),
linkdown(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An overall hardware status for the
port."
::= { connUnitPortEntry 7 }
connUnitPortTransmitterType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
unused(3),
shortwave(4),
longwave(5),
copper(6),
scsi(7),
Blumenau [Page 25]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
longwaveNoOFC(8),
shortwaveNoOFC(9),
longwaveLED(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The technology of the transceiver."
::= { connUnitPortEntry 8 }
connUnitPortModuleType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
gbic(3),
embedded(4), -- fixed, ie, oneXnine
glm(5),
gbicSerialId(6),
gbicNoSerialId(7),
gbicNotInstalled(8),
smallFormFactor(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module type of the port connector."
::= { connUnitPortEntry 9 }
connUnitPortWwn OBJECT-TYPE
SYNTAX FcNameId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The World Wide Name of the port
if applicable, otherwise empty string."
REFERENCE
"See FC elements MIB for FcNameId definition."
::= { connUnitPortEntry 10 }
connUnitPortFCId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the assigned Fibre Channel ID of
this port. This value is expected to be
a Big Endian value of 24 bits. If this is
loop, then it is the ALPA that is connected.
If this is an eport, then it will only
contain the domain ID followed by 16 zero
bits. If this port does not have a Fibre
Channel address, return all bits set to 1."
::= { connUnitPortEntry 11 }
Blumenau [Page 26]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitPortCountWarning OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the warnings that have occured
on this port. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 12 }
connUnitPortCountFailure OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the failures that have occured
on this port. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 13 }
connUnitPortCountLinkdown OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the linkdowns that have occured
on this port. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 14 }
connUnitPortCountAvgSize OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the average size of the unit
of information that has passed through
this port. For Fibre Channel, this would
be frames. For Ethernet, packets. For
SCSI, I/Os. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 15 }
connUnitPortCountAvgRate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the average number of units of
Blumenau [Page 27]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
information that has passed through this
port in the last second. This is expected to
be a Big Endian value. If not applicable,
return all bits set to zero."
::= { connUnitPortEntry 16 }
connUnitPortSn OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the unit (e.g., for
a GBIC). If this is not applicable, return
empty string."
::= { connUnitPortEntry 17 }
connUnitPortRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port revision (e.g., for a GBIC)."
::= { connUnitPortEntry 18 }
connUnitPortVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port vendor (e.g., for a GBIC)."
::= { connUnitPortEntry 19 }
connUnitPortSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The speed of the port in kilobytes per
second."
::= { connUnitPortEntry 20 }
connUnitPortControl OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
invalid(2),
resetConnUnitPort(3),
bypassConnUnitPort(4),
unbypassConnUnitPort(5),
offlineConnUnitPort(6),
onlineConnUnitPort(7),
resetConnUnitPortCounters(8)
}
ACCESS read-write -- (or maybe write-only)
STATUS mandatory
Blumenau [Page 28]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
DESCRIPTION
"This object is used to control the addressed
connUnit's port. Valid commands are:
resetConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'reset' operation. Examples of
these operations are: the Link Reset protocol,
the Loop Initialization protocol, or a
resynchronization occurring between the
transceiver in the addressed port to the
transceiver that the port is connected to.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
bypassConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'bypass' operation. Examples of
these operations are:
the Online to Offline protocol, a
request(NON-PARTICIPATING) command to the
Loop Port state machine, or removal of the
port from an arbitrated loop by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
unbypassConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'unbypass' operation. Examples
of these operations are:
the Link Failure protocol, a
request(PARTICIPATING) command to the
Loop Port state machine, or addition of the
port to an arbitrated loop by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
offlineConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
Blumenau [Page 29]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
vendor-specific 'offline' operation. Examples
of these operations are:
disabling a port's transceiver, the Link
Failure protocol, request(NON-PARTICIPATING)
command to the Loop Port state machine, or
removal of the port from an arbitrated loop
by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request.
onlineConnUnitPort: If the addressed connUnit
allows this operation to be performed to this
port, the addressed port performs a
vendor-specific 'online' operation. Examples
of these operations are:
enabling a port's transceiver, the Link
Failure protocol, request(PARTICIPATING)
command to the Loop Port state machine, or
addition of the port from an arbitrated loop
by a hub.
If the addressed connUnit does not allow this
operation to be performed to this MIB object,
the addressed unit sends back a 'generic error'
SNMP response to the SNMP set request."
::= { connUnitPortEntry 21 }
connUnitPortName OBJECT-TYPE
SYNTAX OCTET STRING -- note: the size of this
-- string is intentionally
-- left undefined
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the addressed connUnit allows sets to be
done to this object, this MIB object can be
used to store a string describing the
addressed port. If the size of the octet
string is larger than the addressed connUnit
can support, the addressed unit sends back a
'tooBig' SNMP response to the SNMP set request.
If the addressed connUnit does not allow writes
to this object, the addressed unit sends back
a 'generic error' SNMP response to the SNMP
set request. The addressed unit may also
return a null string in response to an SNMP
get request for this object."
::= { connUnitPortEntry 22 }
Blumenau [Page 30]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitPortStatusChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last status change occurred."
::= { connUnitPortEntry 23 }
connUnitPortConfigurationChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sysuptime timestamp in centiseconds
at which the last configuration change occurred."
::= { connUnitPortEntry 24 }
connUnitPortPhysicalNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the value that is silk screen on the unit
or the value that the port is known as. This may not
be equal to the index value for the same port."
::= { connUnitPortEntry 25 }
-- event group
connUnitEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of connectivity unit events. Only errors,
warnings, and information (not debugging) should be
reported in this table."
::= { connSet 21 }
connUnitEventEntry OBJECT-TYPE
SYNTAX ConnUnitEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information on
a specific event for the given
connectivity unit."
INDEX { connUnitEventUnitId, connUnitEventIndex }
::= { connUnitEventTable 1 }
Blumenau [Page 31]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
ConnUnitEventEntry ::=
SEQUENCE {
connUnitEventUnitId
OCTET STRING,
connUnitEventIndex
INTEGER (1..2147483647),
connUnitEventId
INTEGER,
connUnitREventTime
DisplayString,
connUnitSEventTime
TimeTicks,
connUnitEventSeverity
INTEGER,
connUnitEventType
INTEGER,
connUnitEventObjectIndex
INTEGER,
connUnitEventDescr
DisplayString
}
connUnitEventUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is identical to connUnitId."
::= { connUnitEventEntry 1 }
connUnitEventIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each connectivity unit
has its own event list. As it wraps, it can
write over previous events that it generated
but not events that other connectivity units
have generated. This is simply used to index
into the table. One would read this table
using getNexts to read each entry till reaching
the end of the table. At that point, one
would again start reading at 1. The management
station will need to track the connUnitEventId
to be able to keep order to the events that
have been read from the unit. The
index value is an incrementing integer starting
from zero every time there is a table reset.
On table reset, all contents are emptied and
all pointers are set to zero. When an
event is added to the table, the event is
assigned the next higher integer value from
the last item entered into the table. If the
Blumenau [Page 32]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
index value reaches its maximum value, the next
item entered will cause the index value to
roll over and start at zero again. The first
event placed in the event table after a
tabpe reset shall have an index value of 1."
::= { connUnitEventEntry 2 }
connUnitEventId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique event Id. Incremented for each
event. Not used as table index to simplify
the agent implementation. If there is a gap
in the values, then it can be assumed that
events have been deleted before read. When this
reaches the end of the range supported by the
number of bits, the Id will roll over to start
at zero. This value will be set back to zero at
reset. The first event generated after a reset
will have an event id of 1. The relationship
of this value to the index is that the index
allows one to address a very small table (eg
100 entries) and would only have a value range
equal to the size of the table. The Id will have
the full range possible by the number of bits
supported and thus allows one to have a unique
value for an event over a longer time period."
::= { connUnitEventEntry 3 }
connUnitREventTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the real time when the event occurred.
It has the following format.
DDMMYYYY HHMMSS
DD=day number
MM=month number
YYYY=year number
HH=hour number
MM=minute number
SS=seconds number
If not applicable, return a NULL string."
::= { connUnitEventEntry 4 }
connUnitSEventTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the sysuptime timestamp when the
Blumenau [Page 33]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
event occurred."
::= { connUnitEventEntry 5 }
connUnitEventSeverity OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The event severity."
::= { connUnitEventEntry 6 }
connUnitEventType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
status(3),
configuration(4),
topology(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of event that has occurred."
::= { connUnitEventEntry 7 }
connUnitEventObjectIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is used with the connUnitEventType
to identify which object. It can be
the OID of a connectivity unit or of
another object like donnUnitPortStatus[...]"
::= { connUnitEventEntry 8 }
connUnitEventDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the event."
::= { connUnitEventEntry 9 }
Blumenau [Page 34]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
-- The link table
-- is intended to organize and communicate
-- any information the agent possesses
-- which would assist a management application
-- to discover the CONNECTIVITY UNITS in the
-- framework and the TOPOLOGY of their interconnect.
-- That is, the goal is to assist the management
-- application not only to LIST the elements of the framework,
-- but to MAP them.
-- With this goal, the agent SHOULD include
-- as much as it possesses about any links
-- from its own connectivity units to others,
-- including links among its own units.
-- An agent SHOULD include partial information
-- about links if it is not able to fully
-- define them in accord with the following structure;
-- however, the information MUST include either
-- a nonzero connUnitNodeId- or a nonzero connUnitPortWwn-
-- for each end of the link.
-- If the agent is able to discover links
-- which do not directly attach to members of its agency
-- and its discovery algorithm gives some assurance
-- the links are recently valid, it MAY include these links.
-- Link information entered by administrative action
-- MAY be included even if not validated directly
-- if the link has at least one endpoint in this agency,
-- but SHOULD NOT be included otherwise.
-- A connectivity unit can fill the table in as best it can.
-- One of the methods to fill this in would be to use the RNID
-- ELS (ANSI document 99-422v0). This allows one to query a
-- port for the information needed for the link table.
-- This table is accessed either directly if the management
-- software has an index value or via GetNexts. The value of
-- the indexes are not required to be contiguous. Each entry
-- created in this table will be assigned an index. This
-- relationship is kept persistent until the entry is removed
-- from the table or the system is reset. The total number of
-- entries are defined by the size of the table
-- For an entry to be considered to be valid, both the X (local)
-- and the Y (remote) need to have one valid value.
connUnitLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnUnitLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of links know to this agent from this
Blumenau [Page 35]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connectivity unit to other connectivity units."
::= { connSet 22 }
connUnitLinkEntry OBJECT-TYPE
SYNTAX ConnUnitLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry describing a particular link to another."
INDEX { connUnitLinkUnitId,
connUnitLinkIndex }
::= { connUnitLinkTable 1 }
ConnUnitLinkEntry ::=
SEQUENCE {
connUnitLinkUnitId
OCTET STRING,
connUnitLinkIndex
INTEGER,
connUnitLinkNodeIdX
OCTET STRING,
connUnitLinkPortNumberX
INTEGER,
connUnitLinkPortWwnX
OCTET STRING,
connUnitLinkNodeIdY
OCTET STRING,
connUnitLinkPortNumberY
INTEGER,
connUnitLinkPortWwnY
OCTET STRING,
connUnitLinkAgentAddressY
OCTET STRING,
connUnitLinkAgentAddressTypeY
INTEGER,
connUnitLinkAgentPortY
INTEGER,
connUnitLinkUnitTypeY
INTEGER,
connUnitLinkConnIdY
OCTET STRING
}
connUnitLinkUnitId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to
the value of connUnitId for the connUnit
associated with one end of this link.
If this link is not or can not be associated
with a connUnit of this agent, the value must
be 16 octets of binary zero"
::= { connUnitLinkEntry 1 }
Blumenau [Page 36]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitLinkIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is used to create a unique value
for each entry in the link table. The value
can only be reused if it is not currently in
in use and the value is the next candidate to
be used. This value is allowed to wrap at the
highest value represented by the number of bits.
This value is reset to zero when the system is
Reset and the first value to be used is one."
::= { connUnitLinkEntry 2 }
connUnitLinkNodeIdX OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node WWN of the unit at one end
of the link. If the node WWN is unknown
and the node is a connUnit
in the responding SNMP agency
then the value of this object
MUST BE equal to its connUnitID."
::= { connUnitLinkEntry 3 }
connUnitLinkPortNumberX OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number on the unit specified by
connUnitLinkNodeIdX if known, otherwise -1.
If the value is nonnegative then it will be
equal to connUnitPortPhysicalNumber."
::= { connUnitLinkEntry 4 }
connUnitLinkPortWwnX OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port WWN of the unit specified by
connUnitLinkNodeIdX if known,
otherwise 16 octets of binary 0"
::= { connUnitLinkEntry 5 }
connUnitLinkNodeIdY OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(64))
ACCESS read-only
STATUS mandatory
Blumenau [Page 37]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
DESCRIPTION
"The node WWN of the unit at the other end
of the link. If the node WWN is unknown
and the node is a connUnit
in the responding SNMP agency
then the value of this object
MUST BE equal to its connUnitID."
::= { connUnitLinkEntry 6 }
connUnitLinkPortNumberY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number on the unit specified by
connUnitLinkNodeIdY if known, otherwise -1.
If the value is nonnegative then it will be
equal to connUnitPortPhysicalNumber."
::= { connUnitLinkEntry 7 }
connUnitLinkPortWwnY OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port WWN on the unit specified by
connUnitLinkNodeIdY if known,
otherwise 16 octets of binary 0"
::= { connUnitLinkEntry 8 }
connUnitLinkAgentAddressY OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of an FCMGMT MIB agent for the
node identified by connUnitLinkNodeIdY,
if known; otherwise 16 octets of binary 0"
::= { connUnitLinkEntry 9 }
connUnitLinkAgentAddressTypeY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If connUnitLinkAgentAddressY is nonzero,
it is a protocol address.
ConnUnitLinkAgentAddressTypeY is the
the 'address family number' assigned by IANA
to identify the address format.
(eg, 1 is Ipv4, 2 is Ipv6)."
::= { connUnitLinkEntry 10 }
Blumenau [Page 38]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
connUnitLinkAgentPortY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP port number for the agent. This is
provided in case the agent is at a non-standard
SNMP port."
::= { connUnitLinkEntry 11 }
connUnitLinkUnitTypeY OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the FC connectivity unit as defined in
connUnitType."
::= { connUnitLinkEntry 12 }
connUnitLinkConnIdY OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the Fibre Channel ID of this port.
If the connectivity unit is a switch, this
is expected to be a Big Endian value of 24
bits. If this is loop, then it is the ALPA
that is connected. If this is an eport, then
it will only contain the domain ID. If not
any of those, unknown or cascaded loop,
return all bits set to 1."
::= { connUnitLinkEntry 13 }
-- SNMP trap registration group
trapMaxClients OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of SNMP trap recipients
supported by the system."
::= { trapReg 1 }
trapClientCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of rows in the trap table."
::= { trapReg 2 }
Blumenau [Page 39]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
trapRegTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapRegEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing a row for each IP address/port
number that traps will be sent to."
::= { trapReg 3 }
trapRegEntry OBJECT-TYPE
SYNTAX TrapRegEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ip/Port pair for a specific client."
INDEX { trapRegIpAddress,
trapRegPort }
::= { trapRegTable 1 }
TrapRegEntry ::=
SEQUENCE {
trapRegIpAddress
IpAddress,
trapRegPort
INTEGER (1..2147483647),
trapRegFilter
INTEGER,
trapRegRowState
INTEGER
}
trapRegIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Ip address of a client registered for
traps. If the addressed connUnit does not allow
writes to this object, addressed unit sends back a
'generic error' SNMP response to the set request."
::= { trapRegEntry 1 }
trapRegPort OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the value of the UDP port that
is in use. If the addressed connUnit does not allow
writes to this object, addressed unit sends back a
'generic error' SNMP response to the set request.
Normally this would be set the standard trap port
Blumenau [Page 40]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
for SNMP but will reflect the port value if it has
been set to a non-standard port."
::= { trapRegEntry 2 }
trapRegFilter OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
informational(3),
warning(4),
critical(5),
failure(6),
init(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the trap severity
that will be generated. It generates all
traps that are greater than or equal to
the value that is set. If the addressed connUnit does
not allow writes to this object, addressed unit sends
back a 'generic error' SNMP response to the set
request. The default value of this object is warning."
::= { trapRegEntry 3}
trapRegRowState OBJECT-TYPE
SYNTAX INTEGER {
rowDestroy(1), -- Remove row from table.
rowInactive(2), -- Row exists, but TRAPs disabled
rowActive(3) -- Row exists and is enabled for
-- sending traps
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the state of the row.
rowDestroy
READ: Can never happen.
WRITE: Remove this row from the table.
rowInactive
READ: Indicates that this row does exist, but
that TRAPs are not enabled to be sent to the
target.
WRITE: If the row does not exist, and the agent
allows writes to the trap table, then a new
row is created. The values of the optional
columns will be set to default values. TRAPs are
not enabled to be sent to the target. If the row
already existed, then TRAPs are disabled from being
sent to the target.
rowActive
READ: Indicates that this row exists, and that TRAPs
are enabled to be sent to the target.
Blumenau [Page 41]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
WRITE: If the row does not exist, and the agent
allows writes to the trap table, then a new row is
created. The values of the optional columns will be
set to default values. TRAPs are enabled to be sent
to the target. If the row alreadt existed, then TRAPs
are enabled to be sent to the target."
::= { trapRegEntry 4}
-- Related traps
connUnitStatusChange TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitStatusChangeTime
}
DESCRIPTION
"The overall status of the connectivity unit has
changed."
::= 1
connUnitAddedTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitId
}
DESCRIPTION
"An event is generated when an entry is added to
the connUnitTable."
::= 2
connUnitDeletedTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitId
}
DESCRIPTION
"An event is generated when an entry is deleted from
the connUnitTable."
::= 3
connUnitEventTrap TRAP-TYPE
ENTERPRISE fcmgmt
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventObjectIndex,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the
connectivity unit."
::= 4
END
Blumenau [Page 42]
INTERNET-DRAFT FC-Mgmt-Int MIB Sept 14, 1999
Author Contact Information:
Steven Blumenau
EMC Corporation
171 South Street
Hopkinton, MA 01748-9103
USA
Phone: 1-508-435-1000 x4657
E-mail: blumenau_steven@isus.emc.com
(This draft expires March 14, 2000.)
Blumenau [Page 43]| PAFTECH AB 2003-2026 | 2026-04-21 03:43:59 |