One document matched: draft-ietf-hubmib-mau-mib-00.txt
Internet Draft 802.3 MAU MIB 27 November 1995
Definitions of Managed Objects
for IEEE 802.3 Medium Attachment Units (MAUs)
<draft-ietf-hubmib-mau-mib-00.txt>
27 November 1995
Dan Romascanu
LANNET Data Communications, Ltd.
dan@lannet.com
Kathryn de Graaf
3Com Corporation
kdegraaf@chipcom.com
Status of this Memo
This document is an Internet-Draft. Internet-Drafts are
working documents of the Internet Engineering Task Force
(IETF), its areas, and its working groups. Note that other
groups may also distribute working documents as Internet-
Drafts.
Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other
documents at any time. It is not appropriate to use Internet-
Drafts as reference material or to cite them other than as a
"work in progress".
To learn the current status of any Internet-Draft, please
check the "1id-abstracts.txt" listing contained in the
Internet-Drafts Shadow Directories on ds.internic.net (US East
Coast), nic.nordu.net (Europe), ftp.isi.edu (US West Coast),
Expires June 1996 [Page 1]
Internet Draft 802.3 MAU MIB 27 November 1995
or munnari.oz.au (Pacific Rim).
Abstract
This memo defines an experimental portion of the Management
Information Base (MIB) for use with network management
protocols in the Internets community. In particular, it
defines objects for managing 10 and 100 Mb/second Medium
Attachment Units (MAUs) based on IEEE Std 802.3 Section 30,
"10 & 100 Mb/s Management," October 26, 1995.
This memo does not specify a standard for the Internet
community.
1. The SNMPv2 Network Management Framework
The SNMPv2 Network Management Framework consists of four major
components. They are:
o RFC 1442 which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of
management.
o STD 17, RFC 1213 defines MIB-II, the core set of managed
objects for the Internet suite of protocols.
o RFC 1445 which defines the administrative and other
architectural aspects of the framework.
o RFC 1448 which defines the protocol used for network
access to managed objects.
The Framework permits new objects to be defined for the
purpose of experimentation and evaluation.
1.1. Object Definitions
Managed objects are accessed via a virtual information store,
termed the Management Information Base or MIB. Objects in the
MIB are defined using the subset of Abstract Syntax Notation
One (ASN.1) defined in the SMI. In particular, each object
Expires June 1996 [Page 2]
Internet Draft 802.3 MAU MIB 27 November 1995
type is named by an OBJECT IDENTIFIER, an administratively
assigned name. The object type together with an object
instance serves to uniquely identify a specific instantiation
of the object. For human convenience, we often use a textual
string, termed the descriptor, to refer to the object type.
Expires June 1996 [Page 3]
Internet Draft 802.3 MAU MIB 27 November 1995
2. Overview
Instances of these object types represent attributes of an
IEEE 802.3 MAU. Several types of MAUs are defined in the IEEE
802.3 CSMA/CD standard [1] and [2]. These MAUs may be
connected to IEEE 802.3 repeaters or to 802.3 (Ethernet-like)
interfaces.
The definitions presented here are based on Section 30.5,
"Layer Management for 10 & 100 Mb/s Medium Attachment Units
(MAUs)", and Annex 30A, "GDMO Specifications for 802.3 managed
objects" of IEEE Std 802.3u-1995. That specification includes
definitions for both 10Mb/s and 100Mb/s devices, and is
essentially a superset of the 10Mb/s definitions given by IEEE
802.3 Section 20. This specification is intended to serve the
same purpose: to provide for management of both 10Mb/s and
100Mb/s MAUs.
MAUs are components that are often located inside a larger
system, and are not always externally visible to a network
administrator. The external connection of a MAU is generally
a jack to which a network cable can be attached. The internal
connection of a MAU can be, as explained above, a repeater
port or an interface. In some systems, this internal
connectivity may be configurable. Additionally, the
introduction of auto-negotiation functionality in the IEEE
802.3 specification allows for a connection which can, to a
certain degree, configure or reconfigure itself during
operation. This MIB includes objects for jack configuration
and status that are intended to allow the network management
software to model and report the connectivity between the
external jacks, the MAUs, and the other components (repeater
ports or interfaces) within such a system, including both
administrative configuration and auto- negotiation. This
model assumes a one-to-one relationship between jacks and
MAUs.
Expires June 1996 [Page 4]
Internet Draft 802.3 MAU MIB 27 November 1995
3. Definitions
MAU-MIB DEFINITIONS ::= BEGIN
IMPORTS
experimental, Counter32, Integer32, Gauge32, Counter64,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TimeStamp, DisplayString, MacAddress, TEXTUAL-CONVENTION,
RowStatus
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP,
FROM SNMPv2-CONF
mib-2
FROM RFC1213-MIB;
mauMod MODULE-IDENTITY
LAST-UPDATED "9511270000Z"
ORGANIZATION "IETF HUB MIB Working Group"
CONTACT-INFO
"WG E-mail: hubmib@baynetworks.com
Chair: Dan Romascanu
Postal: LANNET Data Communications, Ltd.
Atidim Technology Park, Bldg. 3
Tel Aviv 61131, Israel
Tel: 972-3-6458414, 6458458
Fax: 972-3-6487146
E-mail: dan@lannet.com
Editor: Kathryn de Graaf
Postal: 3Com Corporation
118 Turnpike Rd.
Southborough, MA 01772
USA
Tel: (508)229-1627
Fax: (508)490-5882
E-mail: kdegraaf@chipcom.com"
DESCRIPTION
"Management information for 802.3 MAUs.
The following references are used throughout this
MIB module:
Expires June 1996 [Page 5]
Internet Draft 802.3 MAU MIB 27 November 1995
[IEEE 802.3 Std]
refers to IEEE 802.3/ISO 8802-3 Information
processing systems - Local area networks -
Part 3: Carrier sense multiple access with
collision detection (CSMA/CD) access method
and physical layer specifications (1993),
and to IEEE Std 802.3u-1995, Supplement to
IEEE Std 802.3, clauses 22 through 29.
[IEEE 802.3 Mgt]
refers to IEEE 802.3u-1995, - 10 Mb/s &
100 Mb/s Management, Section 30 -
Supplement to IEEE Std 802.3."
::= { snmpDot3MauMgt 6 }
snmpDot3MauMgt OBJECT IDENTIFIER ::= { experimental x }
-- the following subtrees are deprecated
dot3RpMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 }
dot3IfMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 }
dot3BroadMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 }
dot3MauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 7 }
-- object identifiers for MAU types
-- (see rpMauType and ifMauType for usage)
dot3MauType
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 4 }
dot3MauTypeAUI -- no internal MAU, view from AUI
OBJECT IDENTIFIER ::= { dot3MauType 1 }
dot3MauType10Base5 -- thick coax MAU (per 802.3 section 8)
OBJECT IDENTIFIER ::= { dot3MauType 2 }
dot3MauTypeFoirl -- FOIRL MAU (per 802.3 section 9.9)
OBJECT IDENTIFIER ::= { dot3MauType 3 }
dot3MauType10Base2 -- thin coax MAU (per 802.3 section 10)
OBJECT IDENTIFIER ::= { dot3MauType 4 }
dot3MauType10BaseT -- UTP MAU (per 802.3 section 14)
OBJECT IDENTIFIER ::= { dot3MauType 5 }
dot3MauType10BaseFP -- passive fiber MAU (per 802.3 section 16)
OBJECT IDENTIFIER ::= { dot3MauType 6 }
Expires June 1996 [Page 6]
Internet Draft 802.3 MAU MIB 27 November 1995
dot3MauType10BaseFB -- sync fiber MAU (per 802.3 section 17)
OBJECT IDENTIFIER ::= { dot3MauType 7 }
dot3MauType10BaseFL -- async fiber MAU (per 802.3 section 18)
OBJECT IDENTIFIER ::= { dot3MauType 8 }
dot3MauType10Broad36 -- broadband DTE MAU (per 802.3 section 11)
-- note that 10BROAD36 MAUs can be attached to interfaces but
-- not to repeaters
OBJECT IDENTIFIER ::= { dot3MauType 9 }
-- new for 100 MB/s:
dot3MauType100BaseT4 -- 4 pair categ. 3 UTP (per 802.3 section 23)
OBJECT IDENTIFIER ::= { dot3MauType 10 }
dot3MauType100BaseTX -- 2 pair categ. 5 UTP (per 802.3 section 25)
OBJECT IDENTIFIER ::= { dot3MauType 11 }
dot3MauType100BaseFX -- X fiber over PMT (per 802.3 section 26)
OBJECT IDENTIFIER ::= { dot3MauType 12 }
--
-- The Basic MAU Table
--
mauTable OBJECT-TYPE
SYNTAX SEQUENCE OF MauEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of descriptive and status information about
the managed MAU(s) in this system."
::= { mauBasicGroup 1 }
mauEntry OBJECT-TYPE
SYNTAX MauEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing information
about a single MAU."
INDEX { mauGroupIndex, mauIndex }
::= { mauTable 1 }
MauEntry ::=
SEQUENCE {
mauGroupIndex
Expires June 1996 [Page 7]
Internet Draft 802.3 MAU MIB 27 November 1995
Integer32,
mauIndex
Integer32,
mauType
OBJECT IDENTIFIER,
mauTypeList
Integer32,
mauStatus
INTEGER,
mauMediaAvail
INTEGER,
mauMediaAvailStateExits
Counter32,
mauJabberState
INTEGER,
mauJabberingStateEnters
Counter32,
mauFalseCarriers
Counter32
}
mauGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable uniquely identifies the group
containing the MAU described by this entry.
Note: In practice, a group will generally be a
field-replaceable unit (i.e., module, card, or
board) that can fit in the physical system
enclosure, and the group number will correspond to
a number marked on the physical enclosure.
For MAUs attached to repeaters, the group denoted
by a particular value of this object is the same
as the group denoted by the same value of
rptrGroupIndex."
::= { mauEntry 1 }
mauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS mandatory
Expires June 1996 [Page 8]
Internet Draft 802.3 MAU MIB 27 November 1995
DESCRIPTION
"This variable uniquely identifies the MAU within
group mauGroupIndex that is described by this
entry."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID."
::= { mauEntry 2 }
mauType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the 10 or 100 Mb/s
baseband MAU type. An initial set of MAU types
are defined above. The assignment of OBJECT
IDENTIFIERs to new types of MAUs is managed by the
IANA. If the MAU type is unknown, the object
identifier
unknownMauType OBJECT IDENTIFIER ::= { 0 0 }
is returned. Note that unknownMauType is a
syntactically valid object identifier, and any
conformant implementation of ASN.1 and the BER
must be able to generate and recognize this
value."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.2, aMAUType."
::= { mauEntry 3 }
mauTypeList OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
The value is a sum which initially takes the value
zero. Then, for each type capability of this MAU,
2 raised to the power noted below is added to the
sum. For example, a MAU which has the capability
to be only 10BASE-T would have a value of 512
(2**9). In contrast, a MAU which supports both
10Base-T and 100BASE-TX would have a value of 1536
Expires June 1996 [Page 9]
Internet Draft 802.3 MAU MIB 27 November 1995
((2**9) + (2**10)).
The powers of 2 assigned to the capabilities are
these:
Power Capability
1 AUI
2 10BASE-5
3 FOIRL
4 10BASE-2
5 10BASE-T
6 10BASE-FP
7 10BASE-FB
8 10BASE-FL
9 10BROAD36
10 100BASE-T4
11 100BASE-TX
12 100BASE-FX
If auto-negotiation is present on the jack to
which this MAU is attached, this attribute will
map to the jackAutoNegCapability."
::= { mauEntry 4 }
mauStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
operational(3),
standby(4),
shutdown(5),
reset(6)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current state of the MAU. This object may be
implemented as a read-only object by those agents
and MAUs that do not implement software control of
the MAU state. Some agents may not support
setting the value of this object to some of the
enumerated values.
The value other(1) is returned if the MAU is in a
state other than one of the states 2 through 6.
Expires June 1996 [Page 10]
Internet Draft 802.3 MAU MIB 27 November 1995
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional, operates, and passes signals to its
attached DTE or repeater port in accordance to its
specification.
A MAU in standby(4) state forces DI and CI to idle
and the media transmitter to idle or fault, if
supported. Standby(4) mode only applies to link
type MAUs. The state of mauMediaAvail is
unaffected.
A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter as
though it were powered down or not connected. The
MAU may return other(1) value for the
mauJabberState and mauMediaAvail objects when it
is in this state. For an AUI, this state will
remove power from the AUI.
Setting this variable to the value reset(6) resets
the MAU in the same manner as a power-off, power-
on cycle of at least one-half second would. The
agent is not required to return the value reset
(6).
Setting this variable to the value operational(3),
standby(4), or shutdown(5) causes the MAU to
assume the respective state except that setting a
mixing-type MAU or an AUI to standby(4) will cause
the MAU to enter the shutdown state."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acRESETMAU."
::= { mauEntry 5 }
mauMediaAvail OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
available(3),
Expires June 1996 [Page 11]
Internet Draft 802.3 MAU MIB 27 November 1995
notAvailable(4),
remoteFault(5),
invalidSignal(6),
remoteJabber(7),
remoteLinkLoss(8),
remoteTest(9)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the MAU is a link or fiber type (FOIRL,
10BASE-T, 10BASE-F) then this is equivalent to the
link test fail state/low light function. For an
AUI or a coax (including broadband) MAU this
indicates whether or not loopback is detected on
the DI circuit. The value of this attribute
persists between packets for MAU types AUI,
10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP.
The value other(1) is returned if the mediaAvail
state is not one of 2 through 6.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized. At power-up or following a
reset, the value of this attribute will be unknown
for AUI, coax, and 10BASE-FP MAUs. For these MAUs
loopback will be tested on each transmission
during which no collision is detected. If DI is
receiving input when DO returns to IDL after a
transmission and there has been no collision
during the transmission then loopback will be
detected. The value of this attribute will only
change during non-collided transmissions for AUI,
coax, and 10BASE-FP MAUs.
For 100BASE-T4, 100BASE-TX and 100BASE-FX the
enumerations match the states within the
respective link integrity state diagrams, fig 23-
12 and 24-15 of sections 23 and 24 of [2]. Any
MAU which implements management of Auto-
Negotiation will map remote fault indication to
remote fault.
The value available(3) indicates that the link,
Expires June 1996 [Page 12]
Internet Draft 802.3 MAU MIB 27 November 1995
light, or loopback is normal. The value
notAvailable(4) indicates link loss, low light, or
no loopback.
The value remoteFault(5) indicates that a fault
has been detected at the remote end of the link.
This value applies to 10BASE-FB, 100BASE-T4 Far
End Fault Indication and non-specified remote
faults from a system running Auto-Negotiation.
The values remoteJabber(7), remoteLinkLoss(8), and
remoteTest(9) should be used instead of
remoteFault(5) where the reason for remote fault
is identified in the remote signaling protocol.
The value invalidSignal(6) indicates that an
invalid signal has been received from the other
end of the link. Both remoteFault(5) and
invalidSignal(6) apply only to MAUs of type
10BASE-FB.
Where an IEEE Draft Std 802.3u/D4 clause 22 MII is
present, a logic one in the remote fault bit
(reference section 22.2.4.2.8 of that document)
maps to the value remoteFault(5), and a logic zero
in the link status bit (reference section
22.2.4.2.10 of that document) maps to the value
notAvailable(4). The value notAvailable(4) takes
precedence over the value remoteFault(5)."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable."
::= { mauEntry 6 }
mauMediaAvailStateExits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of times that mauMediaAvail
for this MAU instance leaves the state
available(3)."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter."
::= { mauEntry 7 }
mauJabberState OBJECT-TYPE
Expires June 1996 [Page 13]
Internet Draft 802.3 MAU MIB 27 November 1995
SYNTAX INTEGER {
other(1),
unknown(2),
noJabber(3),
jabbering(4)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value other(1) is returned if the jabber
state is not 2, 3, or 4. The agent must always
return other(1) for MAU type dot3MauTypeAUI.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
If the MAU is not jabbering the agent returns
noJabber(3). This is the 'normal' state.
If the MAU is in jabber state the agent returns
the jabbering(4) value."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.6,
aJabber.jabberFlag."
::= { mauEntry 8 }
mauJabberingStateEnters OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). For MAUs of type
dot3MauTypeAUI, dot3MauType100BaseT4,
dot3MauType100BaseTX, and dot3MauType100BaseFX,
this counter will always indicate zero."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.6,
aJabber.jabberCounter."
::= { mauEntry 9 }
mauFalseCarriers OBJECT-TYPE
SYNTAX Counter32
Expires June 1996 [Page 14]
Internet Draft 802.3 MAU MIB 27 November 1995
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of false carrier events
during IDLE in 100BASE-X links. This counter does
not increment at the symbol rate. It can
increment after a valid carrier completion at a
maximum rate of once per 100 ms until the next
carrier event.
This counter increments only for MAUs of type
dot3MauType100BaseT4, dot3MauType100BaseTX, and
dot3MauType100BaseFX. For all other MAU types,
this counter will always indicate zero.
The approximate minimum time for rollover of this
counter is 7.4 hours."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers."
::= { mauEntry 10 }
--
-- Jack Tables
--
-- The jack object types defined below are intended to provide
-- management information for external jacks on a system. They
-- describe the jack from the outside looking in, such that for
-- a particular connector at a particular location on the outside
-- of the box, these objects can be used to determine to which
-- internal entity it is mapped, and to which internal entity it
-- could potentially be mapped as a result of the operation of the
-- auto-negotiation function defined by the IEEE 802.3 management
-- standard.
--
-- The IEEE 802.3 auto-negotiation function is defined such that
-- it can be expanded to work for technologies other than those
-- defined by 802.3. In addition, although the purpose of
-- auto-negotiation is to negotiate the use of a particular
-- (signalling?) technology across a particular link between
-- network components, the outcome of that technology choice
-- can have run-time implications for systems containing a mix
-- of networking features.
--
-- For instance, a system containing both 10 and 100
Expires June 1996 [Page 15]
Internet Draft 802.3 MAU MIB 27 November 1995
-- Mb/s repeater capability on a particular link will,
-- of necessity, require the link to potentially connect to
-- two different repeaters: one 10 Mb/s repeater and one 100
-- Mb/s repeater (there being no such device as a 10/100
-- repeater). Only one of these connections will be active
-- at run time, depending on the outcome of the auto-negotiation
-- on that link, and therefore the auto-negotiation itself can
-- have the effect of determining the actual connectivity of
-- the link.
--
-- These tables are intended to apply firstly to jacks connected to
-- IEEE 802.3 repeaters, and additionally to any other management
-- domain for which they may be useful. Certain object types here
-- have been cross-referenced into the 802.3 repeater MIB (which
-- draft is currently under discussion by this working group) and
-- to the interfaces table of MIB-II. For example, there is
-- some overlap between "jackInternalConnection" and "rptrInfoId"
-- from the repeater MIB draft. Please refer to the object
-- definitions below for specific details.
-- The jackTable applies to systems which have one or
-- more external jacks (connectors).
jackTable OBJECT-TYPE
SYNTAX SEQUENCE OF JackEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration objects for the external jacks on
the system."
::= { jackBasicGroup 1 }
jackEntry OBJECT-TYPE
SYNTAX JackEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing configuration
information for a a particular jack."
INDEX { jackGroupIndex,
jackjackIndex }
::= { jackTable 1 }
JackEntry ::=
Expires June 1996 [Page 16]
Internet Draft 802.3 MAU MIB 27 November 1995
SEQUENCE {
jackGroupIndex
Integer32,
jackIndex
Integer32,
jackType
INTEGER,
jackInternalConnection
OBJECT IDENTIFIER,
jackConnectionLastChange
TimeStamp
}
jackGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable uniquely identifies the group
within the system containing the jack described by
this entry.
Note: In practice, a group will generally be a
field-replaceable unit (i.e., module, card, or
board) that can fit in the physical system
enclosure, and the group number will correspond to
a number marked on the physical enclosure.
For jacks attached to repeaters, the group denoted
by a particular value of this object is the same
as the group denoted by the same value of
rptrGroupIndex."
::= { jackEntry 1 }
jackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable uniquely identifies the jack
described by this entry among within other jacks
within the group denoted by jackGroupIndex.
Note that if the jack is connected to a repeater,
Expires June 1996 [Page 17]
Internet Draft 802.3 MAU MIB 27 November 1995
the value of this object is the same as the value
of rptrPortIndex for the associated port in the
same group (i.e. jackIndex == rptrPortIndex, and
jackGroupIndex == rptrPortGroupIndex).
Jacks may also be connected to other entities,
including logical interfaces within the system, in
which case the numbering of the entity may not
match the numbering of the jack. In all cases,
the next-level entity to which this jack is
connected is specified by the
jackInternalConnection object for this entry."
::= { jackEntry 2 }
jackType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
rj45(2)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The jack connector type, as it appears on the
outside of the system."
::= { jackEntry 3 }
jackInternalConnection OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable identifies the instance of an
internal entity to which the jack is connected.
For a jack which can be administratively
configured, or a jack on which auto-negotiation is
supported, the value of this object may change
between system resets.
If the jack is connected to a repeater, the value
of this object will be rptrInfoId.r, where r
equals the value of rptrPortRptrId for the port
with which this jack is associated (see also the
above description of jackIndex).
If the jack is connected to an interface, the
Expires June 1996 [Page 18]
Internet Draft 802.3 MAU MIB 27 November 1995
value of this object will be ifIndex.i, where i is
the instance of the interface.
For other types of internal entities, the value of
this object must be an instance identifier which
uniquely identifies the entity type and the
instance of that type within the managed system."
::= { jackEntry 4 }
jackConnectionLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when any of the following
conditions occurred:
1) the agent cold- or warm-started;
2) this instance of jack was created
(such as when a device or module was
added to the system);
3) a change occurred in the value of
jackInternalConnection for this entry."
::= { jackEntry 5 }
-- The jackAutoNegTable applies to systems in which
-- auto-negotiation is supported on one or more jacks.
jackAutoNegTable OBJECT-TYPE
SYNTAX SEQUENCE OF JackAutoNegEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration and status objects for the auto-
negotiation function of external jacks on the
system."
::= { jackAutoNegGroup 1 }
jackAutoNegEntry OBJECT-TYPE
SYNTAX JackAutoNegEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing configuration
and status information for the auto-negotiation
Expires June 1996 [Page 19]
Internet Draft 802.3 MAU MIB 27 November 1995
function of a particular jack."
AUGMENTS { jackEntry }
::= { jackAutoNegTable 1 }
JackAutoNegEntry ::=
SEQUENCE {
jackAutoNegAdminStatus
INTEGER,
jackAutoNegRemoteSignaling
INTEGER,
jackAutoNegPotentialConnectSet
Integer32,
jackAutoNegConfig
INTEGER,
jackAutoNegCapability
Integer32,
jackAutoNegCapAdvertised
Integer32,
jackAutoNegCapReceived
Integer32,
jackAutoNegTechnologyInUse
INTEGER,
jackAutoNegRestart
INTEGER
}
jackAutoNegAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to enabled(1) will cause the
interface which has the auto-negotiation signaling
ability to be enabled. If disabled then the
interface will act as it would if it had no auto-
negotiation signaling.
Under these conditions, a jack connected to an
IEEE 802.3 MAU will immediately be forced to the
states indicated by a write to the object
Expires June 1996 [Page 20]
Internet Draft 802.3 MAU MIB 27 November 1995
rpMauType or ifMauType. [Ed.--This doesn't allow
for half vs. full duplex.]"
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.2, aAutoNegAdminState
and 30.6.1.2.2, acAutoNegAdminControl."
::= { jackAutoNegEntry 1 }
jackAutoNegRemoteSignaling OBJECT-TYPE
SYNTAX INTEGER {
detected(1),
notdetected(2)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value indicating whether the remote end of the
link is using auto-negotiation signaling. It takes
the value detected(1) if and only if, during the
previous link negotiation, FLP Bursts were
received."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.3,
aAutoNegRemoteSignaling."
::= { jackAutoNegEntry 2 }
jackAutoNegPotentialConnectSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable identifies the set of internal
entities to which this jack can potentially
connect using as a result of auto-negotiation.
The set of potential connections can include, at
most, one entity supporting each of the
technologies for which this jack has auto-
negotiation capability. For example, if the
jackAutoNegCapability for this entry includes
10Base-T, then one and only one 10Base-T entity
may be included in the jack's potential connection
set.
The members of the set are defined in the
jackAutoNegConnectSetTable; the value of this
Expires June 1996 [Page 21]
Internet Draft 802.3 MAU MIB 27 November 1995
object is the first index
(jackAutoNegConnectSetIndex) into that table.
Each entry in that table whose first index has the
same value as this object is a member of the set
of potential connections for this jack.
Note that this object is read-only, and therefore
does not allow for administrative control of the
jack connection: the method of such control, if
available, is implementation-specific. [?? allow
read-write implementations of this ??]
(See also the definitions for the
jackAutoNegConnectSetTable.)"
::= { jackAutoNegEntry 3 }
jackAutoNegConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
configuring(2),
complete(3),
disabled(4),
parallelDetectFail(5)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value indicating the current status of the
auto-negotiation process. The enumeration
parallelDetectFail(5) maps to a failure in
parallel detection as defined in 28.2.3.1 of [IEEE
802.3 Std]."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.4,
aAutoNegAutoConfig."
::= { jackAutoNegEntry 4 }
jackAutoNegCapability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that uniquely identifies the set of
capabilities of the local auto-negotiation entity.
The value is a sum which initially takes the value
Expires June 1996 [Page 22]
Internet Draft 802.3 MAU MIB 27 November 1995
zero. Then, for each capability of this
interface, 2 raised to the power noted below is
added to the sum. For example, an interface which
has the capability to support only 100Base-TX
would have a value of 512 (2**9). In contrast, an
interface which supports both 100Base-TX and
100Base-TX Full Duplex would have a value of 1536
((2**9) + (2**10)).
The powers of 2 assigned to the capabilities are
these:
Power Capability
1 other
2 reserved
3 10BASE-T
4 10BASE-T Full Duplex
5 10BASE-FL
6 10BASE-FL Full Duplex
7 10BASE-FB
8 10BASE-FB Full Duplex
9 100BASE-TX
10 100BASE-TX Full Duplex
11 100BASE-FX
12 100BASE-FX Full Duplex
13 100BASE-T4
For jacks connected to IEEE 802.3 MAUs, the half-
and full-duplex value pairs each map to a single
MAU type. For example, 10BASE-T and 10BASE-T Full
Duplex each use a MAU type of dot3MauType10BaseT.
Note that interfaces that support this MIB may
have capabilities that extend beyond the scope of
this MIB."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility."
::= { jackAutoNegEntry 5 }
jackAutoNegCapAdvertised OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
Expires June 1996 [Page 23]
Internet Draft 802.3 MAU MIB 27 November 1995
"A value that uniquely identifies the set of
capabilities advertised by the local auto-
negotiation entity. Refer to jackAutoNegCapability
for a description of the possible values of this
object.
Capabilities in this object that are not available
in jackAutoNegCapability cannot be enabled."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { jackAutoNegEntry 6 }
jackAutoNegCapReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that uniquely identifies the set of
capabilities received from the remote auto-
negotiation entity. Refer to jackAutoNegCapability
for a description of the possible values of this
object.
Note that interfaces that support this MIB may be
attached to remote auto-negotiation entities which
have capabilities beyond the scope of this MIB."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { jackAutoNegEntry 7 }
jackAutoNegTechnologyInUse OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reserved(2),
10BASE-T(3),
10BASE-T-FD(4),
10BASE-FL(5),
10BASE-FL-FD(6),
10BASE-FB(7),
10BASE-FB-FD(8),
100BASE-TX(9),
100BASE-TX-FD(10),
100BASE-FX(11),
Expires June 1996 [Page 24]
Internet Draft 802.3 MAU MIB 27 November 1995
100BASE-FX-FD(12),
100BASE-T4(13)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
technology currently in use on the link to which
this jack is attached. This value may be a result
of auto- negotiation on the link. If auto-
negotiation is disabled and the jack is connected
to an IEEE 802.3 MAU, this object will change to
reflect the result of a write to the object
rpMauType or ifMauType."
::= { jackAutoNegEntry 8 }
jackAutoNegRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
norestart(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value of this object is set to restart(1)
then this will force auto-negotiation to begin
link renegotiation. If auto-negotiation signaling
is disabled, a write to this object has no effect.
Setting the value of this object to norestart(2)
has no effect."
REFERENCE
"[IEEE 802.3 Mgt], 30.6.1.2.1,
acAutoNegRestartAutoConfig."
::= { jackAutoNegEntry 9 }
-- The jackAutoNegConnectSetTable applies to systems in which
-- auto-negotiation is supported on one or more jacks.
jackAutoNegConnectSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF JackAutoNegConnectSetEntry
MAX-ACCESS not-accessible
STATUS mandatory
Expires June 1996 [Page 25]
Internet Draft 802.3 MAU MIB 27 November 1995
DESCRIPTION
"A table describing sets of entities within the
system. Each jack in the system, for which auto-
negotiation is supported, is associated with one
of these sets. Each such jack may connect to any
ONE of the entities belonging to the set denoted
by its instance of jackAutoNegPotentialConnectSet,
the choice to be determined by the jack's auto-
negotiation function (if enabled).
Any single set may contain no more than one entity
representing a particular technology to which the
jack can auto-negotiate. For example, a set may
include one and only one 10BASE-T entity (e.g. a
repeater), and one and only one 100BASE-TX full
duplex entity (e.g. an interface). The list of
potential technologies is denoted by the
capabilities enumerated in the
jackAutoNegCapability OBJECT-TYPE description; it
follows that the maximum number of entities in any
set is the same as the number of different
capabilities listed in that description.
It is expected that in a system which supports
administrative configuration of connections, the
administrator will configure the connection set
for a jack so that all of the entity members are
part of a single network, in order that the auto-
negotiation function will not be able to
disconnect and reconnect a link between various
networks supported within the system. That is,
the jackAutoNegPotentialConnectSet is used to
determine the network connection (similarly to the
way a repeater port's repeater id can be used),
but WITHIN that set, the particular entity chosen
is determined via auto-negotiation during
operation."
::= { jackAutoNegGroup 2 }
jackAutoNegConnectSetEntry OBJECT-TYPE
SYNTAX JackAutoNegConnectSetEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry defining one entity of a set of entities
Expires June 1996 [Page 26]
Internet Draft 802.3 MAU MIB 27 November 1995
to which a system jack may potentially connect,
the determination to be made by the jack's auto-
negotiation function."
INDEX { jackAutoNegConnectSet,
jackAutoNegConnectEntityType }
::= { jackAutoNegConnectSetTable 1 }
JackAutoNegConnectSetEntry ::=
SEQUENCE {
jackAutoNegConnectSet
Integer32,
jackAutoNegConnectEntityType
INTEGER,
jackAutoNegConnectEntity
OBJECT IDENTIFIER
}
jackAutoNegConnectSet OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable uniquely identifies a set of entity
instances among the other sets represented within
this table."
::= { jackAutoNegConnectSetEntry 1 }
jackAutoNegConnectEntityType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reserved(2),
10BASE-T(3),
10BASE-T-FD(4),
10BASE-FL(5),
10BASE-FL-FD(6),
10BASE-FB(7),
10BASE-FB-FD(8),
100BASE-TX(9),
100BASE-TX-FD(10),
100BASE-FX(11),
100BASE-FX-FD(12),
100BASE-T4(13)
}
MAX-ACCESS read-only
STATUS mandatory
Expires June 1996 [Page 27]
Internet Draft 802.3 MAU MIB 27 November 1995
DESCRIPTION
"This variable identifies the type of internal
entity about which this entry contains
information. Each set of potential connections
may contain no more than one entry of any
particular technology type."
::= { jackAutoNegConnectSetEntry 2 }
jackAutoNegConnectEntity OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable identifies the instance of an
internal entity to which a jack may potentially
connect. 802.3 repeater and interfaces are
examples of such entities.
Note that if the jack is connected to a repeater,
the value of this object is the same as the value
of rptrPortIndex for the associated port in the
same group (i.e. jackIndex == rptrPortIndex, and
jackGroupIndex == rptrPortGroupIndex).
Jacks may also be connected to other types of
entities, including logical interfaces within the
system, in which case the numbering of the entity
may not match the numbering of the jack. In all
cases, the next-level entity to which this jack is
connected is specified by the
jackInternalConnection object for this entry."
::= { jackAutoNegConnectSetEntry 3 }
-- Notifications for use by 802.3 MAUs
mauJabberTrap NOTIFICATION-TYPE
OBJECTS { mauJabberState }
DESCRIPTION
"This trap is sent whenever a managed repeater MAU
enters the jabber state.
The agent must throttle the generation of
consecutive mauJabberTraps so that there is at
Expires June 1996 [Page 28]
Internet Draft 802.3 MAU MIB 27 November 1995
least a five-second gap between them."
REFERENCE
"[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber
notification."
::= { snmpDot3MauMgt 0 1 }
END
Expires June 1996 [Page 29]
Internet Draft 802.3 MAU MIB 27 November 1995
4. References
[1] IEEE 802.3/ISO 8802-3 Information processing systems -
Local area networks - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access method
and physical layer specifications, 1993.
[2] IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium
Attachment Units and Repeater for 100 Mb/s Operation,
Type 100BASE-T," Sections 21 through 29, Supplement to
IEEE Std 802.3, October 26, 1995.
[3] IEEE 802.3u-1995, "10 & 100 Mb/s Management," Section 30,
Supplement to IEEE Std 802.3, October 26, 1995.
[4] Romascanu, D., and K. de Graaf, "Definitions of Managed
Objects for IEEE 802.3 Repeater Devices", November 1995.
Expires June 1996 [Page 30]
| PAFTECH AB 2003-2026 | 2026-04-24 00:06:31 |