<title abbrev='Consider Energy'>Considerations for Power and Energy Management</title>
<author initials='B.' surname="Nordman" fullname='Bruce Nordman'>
<organization>Lawrence Berkeley National Laboratory</organization>
<address>
<email>bnordman@lbl.gov</email>
</address>
</author>
<author initials='R.' surname="Winter" fullname='Rolf Winter'>
<organization>NEC Labs Europe</organization>
<address>
<email>rolf.winter@neclab.eu</email>
</address>
</author>
<date/>
<abstract><t>With rising cost and an increasing awareness of the environmental
impact of energy consumption, a desirable feature of networked
devices is to be able to assess their power state and energy
consumption at will. With this data available, one can build
sophisticated applications such as monitoring applications or even
active energy management systems. These systems themselves are out
of scope of this memo, as it discusses only considerations for the
monitored devices. Implementation specifics such as the definition
of a Management Information Base are also outside the scope of this
document.
</t></abstract>
</front>
<middle>
<section title="Requirements notation">
<t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL",
"SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY",
and "OPTIONAL" in this document are to be interpreted as
described in <xref target="RFC2119"/>.</t>
</section>
<section title="Overview/Goals">
<t>This document aims at framing discussions on power
and energy management within the IETF and recording their results.
It clarifies terminology that is routinely used to
have multiple contrary meanings, which results in unnecessary confusion.
The document further describes how energy and power reporting differs
from other reporting tasks that have been defined by the IETF
and the resulting implications for mechanisms the IETF will
define. This document is intended to be a living
document that also captures why certain decisions were made
in the process of defining power and energy management mechanisms.</t>
</section>
<section title="Settled topics">
<t>
The following are topics that seem settled in eman discussions, recognizing
that this draft has no authority on that point.
</t>
<section title="Scope of Devices">
<t>All energy-using devices that have a network connection are in scope.
The eman mechanisms also provide for non-IP devices that are supplied with power
or that have power metered by an IP device, or are brought into the eman context
by a gateway/proxy.
</t>
<t>While first adopters will surely be devices such as switches, routers, and
servers (some of which already report power levels and power state
through proprietary means), in the future networked electronic
devices, appliances, and even lights will also need such capability.
These devices may have different ways of accomplishing discovery and
management for functional purposes, but will share the common energy and
power reporting capability. While some devices will directly
measure power, other devices will not be able to measure their power, but may be
able to reliably estimate it. These devices are still in scope.</t>
</section>
<section title="Identity">
<t>Some universal mechanisms for identity are needed so that the NMS knows
what the devices are that are using energy. The nature of these mechanisms,
whether they are existing ones to be referenced or new ones to be created
(almost certainly some of both) has not yet been determined.
</t>
</section>
<section title="Power Levels">
<t>The power level of a device is its current electricity demand. It is an
important complement to power mode, providing articulation of
power level within the basic mode. It also avoids the need for a large
number of named modes. Basic modes are distinguished by important
functional differences or power levels. Core power modes are an
abstraction from individual implementations.</t>
</section>
<section title="Devices">
<t>The organizing unit for power is a single device with one or more
power sources. The term "product" is sometimes used as a synonym,
and also covers the case in which a device proxies network presence
including power reporting for a second device.</t>
</section>
<section title="Intervals">
<t>A common feature of energy monitoring is to track energy use over time.
Recording of energy use for intervals of time is the responsibility of a
network management system (or whatever entity requests data via the eman
protocol), not the monitored device itself.
The monitored device always reports accumulated energy use with an
associated timestamp.</t>
</section>
<section title="Presentation to non-IETF audiences">
<t>Many people and organizations who have not in the past understood or
interacted with the IETF will be interested in eman results.
They need to be provided with easily understandable explanations of what
eman does and why. How this presentation will be accomplished is still
to be determined.</t>
</section>
<section title="Functions vs. Entities">
<t>Eman is concerned with exposing information to Network Management
Systems (NMSs).
Providing information is a function.
The various functions may be implemented by a single device, or distributed
among several devices.</t>
</section>
<section title="Simple and Complex Devices">
<t>We will support both.
Simple devices want to avoid complexity that burdens both implementation
on the monitored device, and the monitoring system.
Complex devices need to have access to additional data fields and
capabilities.</t>
</section>
</section>
<section title="Topics under discussion">
<section title="Power States">
<t>We synonymously use the terms Power Mode and Power
State; named modes are general categories only ("buckets"), not individual states
with highly-specific meaning.</t>
<t>Discussions about energy consumptions and device power states are
often confusing as different products define states such as
“standby” quite differently. Even the same class of devices often
implement named states differently. Named power states are
intrinsically difficult to define consistently as they imply not only
something about a device's energy consumption but also something
about the device's capabilities in that state, and are implementation-dependent.
All of this makes highly-specific named modes unsuitable for use in
a general context. The term with by far the most different definitions
is “standby” and so we therefore do not refer to standby in
this document and believe it unsuitable for use in eman.
</t>
<t>We believe that the three named power state categories,
on, off and sleep, are broadly understood. These mode categories may each
contain a large set of power sub-states. A fourth basic power state of
'ready' may be more appropriate for some devices, particularly appliances.</t>
<t>In general, devices that are asleep will be able to wake quickly and
will retain network connectivity. Devices that are off usually take
much more time to turn on than the wake time and usually lack network
connectivity. Devices that are on are fully functional but
potentially with reduced performance.</t>
<t>A critical feature of the set of basic power states is that they should
be universally applicable to any device eman is applied to.
This does not mean that each device has every state, but that the model
is sufficiently general that it can be applied to all.
When the level of detail rises, the set of states usually is then
applicable to only certain types of products, and/or to specific
implementations.
In addition, these detailed states generally embody specific functional
characteristics of the state, and so are better embodied in other
variables (that may be delivered by an energy management protocol).
</t>
</section>
</section>
<section title="Energy Manangement">
<t>First and foremost, the task of power and energy management is
reporting. While a more active role in energy management is
conceivable by e.g. putting devices into power states based on
policies or other predefined schemes at a network management system
(NMS).</t>
<section title="Control">
<t>There should not be an assumption that power state management of
devices is done externally/centrally. Ideally most devices will
manage their own power state, implementing distributed intelligence.
The control function is accomplished separately from power reporting.
A core mechanism many devices will use to manage power consumption
is a price (and price forecast) for electricity.</t>
</section>
<section title="Identity">
<t>All devices on a network need to expose identity to others.
While some protocols accomplish this for particular applications or
contexts, it is desirable to have a simple universal mechanism.
This is particularly true for devices that may have a fairly limited
degree of participation in the network, such as appliances.
</t>
<t>
For energy management purposes, the it is important to know "what"
a device is, and "who" it is. Each of these has two parts as follows:
<list style='symbols'>
<t>"Species". This is the fundamental classification that a device
is a member of due to its design and capabilities. This property
is determined by the manufacturer before it is sold.
Examples are server, router, notebook PC, display, TV, refrigerator,
light, etc.
</t>
<t>"Origin". The brand and model of the device. Primarily
a method to find out more information about a device, such as its
specifications for requirements and capabilities.
It would be advantageous to include a URL for detailed information
from the manufacturer.
An example of this is the "Universal Product Code" on many products.</t>
<t>Name: A human-readable name, locally specified when the device is
configured or installed. </t>
<t>Network ID: A globally unique identifier for the NMS to use
to recognize a device. This should be based on one or more
existing IETF mechanisms.</t>
</list>
</t>
<t>An energy management application could then obtain
current energy use for a device like a refrigerator, and compare it
to what it is expected to use under normal operation, and alert the
building manager if it is significantly out of range. This also can
be used to quickly inventory energy-using products in a building, and
to summarize by product type where energy is being used.</t>
</section>
<section title="NMS Considerations">
<t>A Network Management System is an entity which collects
energy and power reporting data and uses it for advanced
applications. One such application correlates energy
consumption with other metrics to display efficiency
metrics (like watthours/bit). An NMS can also
set device policies to control larger networked
systems such as a data center.</t>
<t>An NMS will query energy MIB data on a periodic basis, with that
period dictated by its needs, possibly being dynamic. MIBs should
provide an energy "meter reading" to allow computing of energy use for any
period. Thus, the NMS does most of the work to generate time series
energy data, and this minimizes burden on the host and the complexity
of the Power MIB.</t>
<t>The core function of power monitoring is to maintain
meters of energy use and of time in different power states (and
through summing, total energy and time). The second is to be able to
report current power consumption and power state.</t>
</section>
<section title="MIB Considerations">
<t>The MIB should be generic as there are a large number of devices yet
to come and power states are and will become more diverse.</t>
<t>The MIB should be structured so that the smallest possible set of
values/information is applicable to a large range of devices, can be
implemented efficiently and is extensible to accommodate additional
information objects. As an example, many devices will not be battery
powered but it should be easy to add battery monitoring to the basic
set of energy-related information.</t>
<t>The proposed MIB structures enable reporting on components of products
(e.g. linecards in a chassis) in addition to entire products.
Doing this is not part of the eman charter, so while there is no reason
to preclude the capability, it should not be a distraction to completing
the chartered eman scope.
</t>
</section>
<section title="Power Considerations">
<t>Reporting should cover both AC and DC power sources. However,
other types should be provided for, and the type of energy is one of the
reported values.
Standard low-voltage DC (e.g. USB, Power over Ethernet, eMerge) is
immediately useful. A core set of values should be available from any
device that implements the Power MIB at all so that an NMS can quickly
obtain and aggregate uniform data for all devices.</t>
<t>There is a fundamental distinction between supplied power from a device
And input power to a device, notably losses that occur in transmission,
as well as other (possibly unknown) devices that are also using the power.
The effect of internal batteries is not revealed by the MIB, as it only
reports on net power into or out of a device.</t>
</section>
<section title="Incomplete data">
<t>Energy reporting will cover a wide variety of information about a
device, its status, and energy usage. Sometimes, particularly for
legacy or non-IP products, this will be incomplete. It is critical
that the fact that some data are missing does not undermine the
ability to report the data that are present.</t>
</section>
<section title="Time reporting">
<t>At the core of energy reporting is data from energy meters that
are meter readings associated with timestamps. A variety of issues
arise on the meaning of that time.</t>
<t>Without strong syncronization, the NMS and the devices it queries
will have different absolute times. However, the NMS knows when
it asked for each meter reading so can account for this difference.
</t>
<t>For some devices, when they are off they will be unable to
accumulate their energy consumption. The fact that some consumption
may be missing needs to be communicated to the NMS.
One possibility is to record the last time that a period
of missing energy occurred, and report that to the NMS.
</t>
</section>
<section title="Portable devices">
<t>Devices that are routinely moved from one building to another
(or even within a building) pose special challenges for energy
reporting. The question arises whether it is the energy into
the device, or from the building, which is dominant.
It may be important to record the time a device most
recently changed power domain to ensure that a NMS can
correctly account only for energy consumed on its premises.</t>
</section>
<section title="Beyond energy">
<t>The charter references “energy” but virtually all discussion has
been limited to electricity.
Other forms of energy should be included at some point; we should
discuss whether this is readily feasible now, or needs to be postponed to
future work.
</t>
</section>
<section title="Power State Monitoring">
<t>For the device power state, the following information is considered
to be relevant:
<list style='symbols'>
<t>the current state</t>
<t>the time of (or time since) the last change</t>
<t>the current real power (energy consumption rate)</t>
<t>accumulated energy consumption</t>
</list>
</t>
</section>
<section title="Power Distribution">
<t>Wired networks enable power distribution that is co-incident with network
Communication. However, many devices will not communicate on the same
Medium that they are powered on, or may lack connectivity entirely (though
with the power provider knowing of their identity). Devices can report power
for another device only if they are the entity providing the power.</t>
</section>
</section>
<section title="Use Context and Use Cases">
<t>The following are some use contexts that this facility is intended for.
These are not necessarily mutually exclusive, and a device can report the
same data regardless of the context.
<list style='symbols'>
<t>A data center, with a NMS which is integrated with application
functionality, and also manages energy use.</t>
<t>A commercial building, in which the energy reporting is separate
from any management of devices, and more as background to help
understand building operation (including occupancy) and identify
inefficiencies or equipment failures.</t>
<t>A house, which shares some of the commercial building
characteristics, but with different management approach and
security concerns.</t>
<t>A vehicle, which uses the reporting only for automatic management,
not for reporting to the user.</t>
</list>
</t>
<t>Use cases include a facility manager or an NMS in an automated fashion:
<list style='symbols'>
<t>Understand costs for billing purposes.</t>
<t>Assess savings potentials.</t>
<t>Identify possible device malfunctions.</t>
<t>Reveal unexpected usage patterns.</t>
<t>Plan for future capacity needs.</t>
<t>Understand heat production in a building or space.</t>
<t>A NMS which deals with draws on current power use to deal with
an actual or potential shortfall in power supply.</t>
</list>
</t>
</section>
<section title="Future Directions">
<t>The current effort to create a protocol for energy management is unlikely
to be the last word on the topic. In fact, there are
many directions that need to be explored for potential addition to
the features enabled by this mechanism or others. These include:
<list style='symbols'>
<t>other energy media such as wireless power, non-electric energy
(e.g. natural gas, steam, hot/cold water).</t>
<t>more features for control.</t>
<t>other energy-relevant quantities (e.g. temperatures, flow rates).</t>
<t>other resources (e.g. water).</t>
</list>
</t>
</section>