<?xml version="1.0" encoding="US-ASCII"?>
<!DOCTYPE rfc SYSTEM "rfc2629.dtd">
<rfc category="bcp" docName="draft-ietf-tsvwg-circuit-breaker-07"
ipr="trust200902" obsoletes="" updates="">
<!-- Updates SDP -->
<?rfc toc="yes"?>
<!-- generate a table of contents -->
<?rfc symrefs="yes"?>
<!-- use anchors instead of numbers for references -->
<?rfc sortrefs="yes" ?>
<!-- alphabetize the references -->
<?rfc compact="yes" ?>
<!-- conserve vertical whitespace -->
<?rfc subcompact="no" ?>
<!-- but keep a blank line between list items -->
<front>
<title abbrev="">Network Transport Circuit Breakers</title>
<author fullname="Godred Fairhurst" initials="G." surname="Fairhurst">
<organization>University of Aberdeen</organization>
<address>
<postal>
<street>School of Engineering</street>
<street>Fraser Noble Building</street>
<city>Aberdeen</city>
<region>Scotland</region>
<code>AB24 3UE</code>
<country>UK</country>
</postal>
<email>gorry@erg.abdn.ac.uk</email>
<uri>http://www.erg.abdn.ac.uk</uri>
</address>
</author>
<date day="19" month="October" year="2015" />
<area>Transport</area>
<workgroup>TSVWG Working Group</workgroup>
<keyword></keyword>
<keyword></keyword>
<abstract>
<t>This document explains what is meant by the term "network transport
Circuit Breaker" (CB). It describes the need for circuit breakers when
using network tunnels, and other non-congestion controlled applications,
and explains where circuit breakers are, and are not, needed. It also
defines requirements for building a circuit breaker and the expected
outcomes of using a circuit breaker within the Internet.</t>
</abstract>
</front>
<middle>
<!-- text starts here -->
<section title="Introduction" toc="include">
<t>A network transport Circuit Breaker (CB) is an automatic mechanism
that is used to estimate congestion caused by a flow, and to terminate
(or significantly reduce the rate of) the flow when persistent
congestion is detected. This is a safety measure to prevent starvation
of network resources denying other flows from access to the Internet,
such measures are essential for an Internet that is heterogeneous and
for traffic that is hard to predict in advance. Avoiding persistent
prevention is important to reduce the potential for "Congestion
Collapse" <xref target="RFC2914"></xref>.</t>
<t>The term "Circuit Breaker" originates in electricity supply, and has
nothing to do with network circuits or virtual circuits. In electricity
supply, a Circuit Breaker is intended as a protection mechanism of last
resort. Under normal circumstances, a Circuit Breaker ought not to be
triggered; it is designed to protect the supply network and attached
equipment when there is overload. Just as people do not expect the
electrical circuit-breaker (or fuse) in their home to be triggered,
except when there is a wiring fault or a problem with an electrical
appliance.</t>
<t>In networking, the Circuit Breaker principle can be used as a
protection mechanism of last resort to avoid persistent congestion
impacting other flows that share network capacity. Persistent congestion
was a feature of the early Internet of the 1980s. This resulted in
excess traffic starving other connection from access to the Internet. It
was countered by the requirement to use congestion control (CC) by the
Transmission Control Protocol (TCP) <xref target="Jacobsen88"></xref>
<xref target="RFC1112"></xref>. These mechanisms operate in Internet
hosts to cause TCP connections to "back off" during congestion. The
introduction of a Congestion Controller in TCP (currently documented in
<xref target="RFC5681"></xref> ensured the stability of the Internet,
because it was able to detect congestion and promptly react. This worked
well while TCP was by far the dominant traffic in the Internet, and most
TCP flows were long-lived (ensuring that they could detect and respond
to congestion before the flows terminated). This is no longer the case,
and non-congestion controlled traffic, including many applications of
the User Datagram Protocol (UDP) can form a significant proportion of
the total traffic traversing a link. The current Internet therefore
requires that non-congestion controlled traffic needs to be considered
to avoid persistent congestion.</t>
<t>There are important differences between a transport circuit-breaker
and a congestion-control method. Specifically, congestion control (as
implemented in TCP, SCTP, and DCCP) operates on the timescale on the
order of a packet round-trip-time (RTT), the time from sender to
destination and return. Congestion control methods are able to react to
a single packet loss/marking and reduce the transmission rate for each
loss or congestion event. The goal is usually to limit the maximum
transmission rate to a rate that reflects the available capacity across
a network path. These methods typically operate on individual traffic
flows (e.g., a 5-tuple).</t>
<t>In contrast, Circuit Breakers are recommended for
non-congestion-controlled Internet flows and for traffic aggregates,
e.g., traffic sent using a network tunnel. People have been implementing
what this draft characterizes as circuit breakers on an ad hoc basis to
protect Internet traffic, this draft therefore provides guidance on how
to deploy and use these mechanisms. Later sections provide examples of
cases where circuit-breakers may or may not be desirable.</t>
<t>A Circuit Breaker needs to measure (meter) the traffic to determine
if the network is experiencing congestion and needs to be designed to
trigger robustly when there is persistent congestion. This means the
trigger needs to operate on a timescale much longer than the path round
trip time (e.g., seconds to possibly many tens of seconds). This longer
period is needed to provide sufficient time for transports (or
applications) to adjust their rate following congestion, and for the
network load to stabilize after any adjustment.</t>
<t>A Circuit Breaker trigger will often utilize a series of successive
sample measurements metered at an ingress point and an egress point
(either of which could be a transport endpoint). These measurements need
to be taken over a reasonably long period of time. This is to ensure
that a Circuit Breaker does not accidentally trigger following a single
(or even successive) congestion events (congestion events are what
triggers congestion control, and are to be regarded as normal on a
network link operating near its capacity). Once triggered, a control
function needs to remove traffic from the network, either by disabling
the flow or by significantly reducing the level of traffic. This
reaction provides the required protection to prevent persistent
congestion being experienced by other flows that share the congested
part of the network path.</t>
<t><xref target="Require"></xref> defines requirements for building a
Circuit Breaker.</t>
<section title="Types of Circuit-Breaker">
<t>There are various forms of network transport circuit breaker. These
are differentiated mainly on the timescale over which they are
triggered, but also in the intended protection they offer:<list
style="symbols">
<t>Fast-Trip Circuit Breakers: The relatively short timescale used
by this form of circuit breaker is intended to provide protection
for network traffic from a single flow or related group of
flows.</t>
<t>Slow-Trip Circuit Breakers: This circuit breaker utilizes a
longer timescale and is designed to protect network traffic from
congestion by traffic aggregates.</t>
<t>Managed Circuit Breakers: Utilize the operations and management
functions that might be present in a managed service to implement
a circuit breaker.</t>
</list>Examples of each type of circuit breaker are provided in
section 4.</t>
</section>
</section>
<section title="Terminology" toc="include">
<t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in <xref
target="RFC2119"></xref>.</t>
</section>
<section title="Design of a Circuit-Breaker (What makes a good circuit breaker?)"
toc="include">
<t>Although circuit breakers have been talked about in the IETF for many
years, there has not yet been guidance on the cases where circuit
breakers are needed or upon the design of circuit breaker mechanisms.
This document seeks to offer advice on these two topics.</t>
<t>Circuit Breakers are RECOMMENDED for IETF protocols and tunnels that
carry non-congestion-controlled Internet flows and for traffic
aggregates. This includes traffic sent using a network tunnel. Designers
of other protocols and tunnel encapsulations also ought to consider the
use of these techniques to provide last resort to protect traffic that
shares the network path being used.</t>
<t>This document defines the requirements for design of a Circuit
Breaker and provides examples of how a Circuit Breaker can be
constructed. The specifications of individual protocols and tunnel
encapsulations need to detail the protocol mechanisms needed to
implement a Circuit Breaker.</t>
<t>Section 3.1 describes the functional components of a circuit breaker
and section 3.2 defines requirements for implementing a Circuit
Breaker.</t>
<section title="Functional Components" toc="include">
<t>The basic design of a transport circuit breaker involves
communication between an ingress point (a sender) and an egress point
(a receiver) of a network flow or set of flows. A simple picture of
Circuit Breaker operation is provided in figure 1. This shows a set of
routers (each labelled R) connecting a set of endpoints.</t>
<t>A Circuit Breaker is used to control traffic passing through a
subset of these routers, acting between the ingress and a egress point
network devices. The path between the ingress and egress could be
provided by a tunnel or other network-layer technique. One expected
use would be at the ingress and egress of a service, where all traffic
being considered terminates beyond the egress point, and hence the
ingress and egress carry the same set of flows.</t>
<figure>
<artwork><![CDATA[
+--------+ +--------+
|Endpoint| |Endpoint|
+--+-----+ >>> circuit breaker traffic >>> +--+-----+
| |
| +-+ +-+ +---------+ +-+ +-+ +-+ +--------+ +-+ +-+ |
+-+R+--+R+->+ Ingress +--+R+--+R+--+R+--+ Egress |--+R+--+R+-+
+++ +-+ +------+--+ +-+ +-+ +-+ +-----+--+ +++ +-+
| ^ | | |
| | +--+------+ +------+--+ |
| | | Ingress | | Egress | |
| | | Meter | | Meter | |
| | +----+----+ +----+----+ |
| | | | |
+-+ | | +----+----+ | | +-+
|R+--+ | | Measure +<----------------+ +--+R|
+++ | +----+----+ Reported +++
| | | Egress |
| | +----+----+ Measurement |
+--+-----+ | | Trigger + +--+-----+
|Endpoint| | +----+----+ |Endpoint|
+--------+ | | +--------+
+---<---+
Reaction
]]></artwork>
</figure>
<t>Figure 1: A CB controlling the part of the end-to-end path between
an ingress point and an egress point. (Note: In some cases, the
trigger and measure functions could alternatively be located at other
locations (e.g., at a network operations centre.)</t>
<t>In the context of a Circuit Breaker, the ingress and egress
functions could be implemented in different places. For example, they
could be located in network devices at a tunnel ingress and at the
tunnel egress. In some cases, they could be located at one or both
network endpoints (see figure 2), implemented as components within a
transport protocol.</t>
<t><figure>
<artwork><![CDATA[
+----------+ +----------+
| Ingress | +-+ +-+ +-+ | Egress |
| Endpoint +->+R+--+R+--+R+--+ Endpoint |
+--+----+--+ +-+ +-+ +-+ +----+-----+
^ | |
| +--+------+ +----+----+
| | Ingress | | Egress |
| | Meter | | Meter |
| +----+----+ +----+----+
| | |
| +--- +----+ |
| | Measure +<-----------------+
| +----+----+ Reported
| | Egress
| +----+----+ Measurement
| | Trigger |
| +----+----+
| |
+---<--+
Reaction
]]></artwork>
</figure></t>
<t>Figure 2: An endpoint CB implemented at the sender (ingress) and
receiver (egress).</t>
<t>The set of components needed to implement a Circuit Breaker
are:</t>
<t><list style="numbers">
<t>An ingress meter (at the sender or tunnel ingress) records the
number of packets/bytes sent in each measurement interval. This
measures the offered network load for a flow or set of flows. For
example, the measurement interval could be many seconds (or every
few tens of seconds or a series of successive shorter measurements
that are combined by the Circuit Breaker Measurement
function).</t>
<t>An egress meter (at the receiver or tunnel egress) records the
number/bytes received in each measurement interval. This measures
the supported load for the flow or set of flows, and could utilize
other signals to detect the effect of congestion (e.g.,
loss/marking experienced over the path). The measurements at the
egress could be synchronised (including an offset for the time of
flight of the data, or referencing the measurements to a
particular packet) to ensure any counters refer to the same span
of packets.</t>
<t>The measured values at the ingress and egress are communicated
to the Circuit Breaker Measurement function. This could use
several methods including: Sending return measurement packets from
a receiver to a trigger function at the sender; An implementation
using Operations, Administration and Management (OAM); or be
sending another in-band signalling datagram to the trigger
function. This could also be implemented purely as a control plane
function, e.g., using a software-defined network controller.</t>
<t>The measurement function combines the ingress and egress
measurements to assess the present level of network congestion.
(For example, the loss rate for each measurement interval could be
deduced from calculating the difference between ingress and egress
counter values.) Note the method does not require high accuracy
for the period of the measurement interval (or therefore the
measured value, since isolated and/or infrequent loss events need
to be disregarded.)</t>
<t>A trigger function determines if the measurements indicate
persistent congestion. This function defines an appropriate
threshold for determining there is persistent congestion between
the ingress and egress. This preferably considers a rate or ratio,
rather than an absolute value (e.g., more than 10% loss, but other
methods could also be based on the rate of transmission as well as
the loss rate). The transport Circuit Breaker is triggered when
the threshold is exceeded in multiple measurement intervals (e.g.,
3 successive measurements). Designs need to be robust so that
single or spurious events do not trigger a reaction.</t>
<t>A reaction that is applied that the Ingress when the Circuit
Breaker is triggered. This seeks to automatically remove the
traffic causing persistent congestion.</t>
<t>A feedback mechanism that triggers when either the receive or
ingress and egress measurements are not available, since this also
could indicate a loss of control packets (also a symptom of heavy
congestion or inability to control the load).</t>
</list></t>
</section>
</section>
<section anchor="Require"
title="Requirements for a Network Transport Circuit Breaker">
<t>The requirements for implementing a Circuit Breaker are:</t>
<t><list style="symbols">
<t>There MUST be a communication path used for control messages from
the ingress meter and the egress meter to the point of measurement.
The Circuit Breaker MUST trigger if there is a failure of the
communication path used for the control messages. That is, the
feedback indicating a congested period needs to be designed so that
the Circuit Breaker is triggered when it fails to receive
measurement reports that indicate an absence of congestion, rather
than relying on the successful transmission of a "congested" signal
back to the sender. (The feedback signal could itself be lost under
congestion).</t>
<t>A Circuit Breaker MUST define a measurement period over which the
Circuit Breaker Measurement function measures the level of
congestion or loss. This method does not have to detect individual
packet loss, but MUST have a way to know that packets have been
lost/marked from the traffic flow. If Explicit Congestion
Notification (ECN) is enabled <xref target="RFC3168"></xref>, an
egress meter MAY also count the number of ECN congestion marks/event
per measurement interval, but even if ECN is used, loss MUST still
be measured, since this better reflects the impact of persistent
congestion. In this context, loss represents a reliable indication
of congestion, as opposed to the finer-grain marking of incipient
congestion that can be provided via ECN. The type of Circuit Breaker
will determine how long this measurement period needs to be.</t>
<t>The measurement period used by a Circuit Breaker Measurement
function MUST be longer than the time that current Congestion
Control algorithms need to reduce their rate following detection of
congestion. This is important because end-to-end Congestion Control
algorithms require at least one RTT to notify and adjust the traffic
to experienced congestion, and congestion bottlenecks can share
traffic with a diverse range of RTTs. The measurement period is
therefore expected to be significantly longer than the RTT
experienced by the Circuit Breaker itself.</t>
<t>If necessary, MAY combine successive individual meter samples
from the ingress and egress to ensure observation of an average over
a sufficiently long interval. (Note when meter samples need to be
combined, the combination needs to reflect the sum of the individual
sample counts divided by the total time/volume over which the
samples were measured. Individual samples over different intervals
can not be directly combined to generate an average value.)</t>
<t>A Circuit Breaker is REQUIRED to define a threshold to determine
whether the measured congestion is considered excessive.</t>
<t>A Circuit Breaker is REQUIRED to define the triggering interval,
defining the period over which the trigger uses the collected
measurements. Circuit Breakers need to trigger over a sufficiently
long period to avoid additionally penalizing flows with a long path
RTT (e.g., many path RTTs).</t>
<t>A Circuit Breaker MUST be robust to multiple congestion events.
This usually will define a number of measured persistent congestion
events per triggering period. For example, a Circuit Breaker MAY
combine the results of several measurement periods to determine if
the Circuit Breaker is triggered. (e.g., triggered when persistent
congestion is detected in 3 of the measurements within the
triggering interval).</t>
<t>A Circuit Breaker SHOULD be constructed so that it does not
trigger under light or intermittent congestion.</t>
<t>The default response to a trigger SHOULD disable all traffic that
contributed to congestion.</t>
<t>Once triggered, the Circuit Breaker MUST react decisively by
disabling or significantly reducing traffic at the source (e.g.,
ingress). A reaction that results in a reduction SHOULD result in
reducing the traffic by at least an order of magnitude, each time
the Circuit Breaker is triggered. This response needs to be much
more severe than that of a Congestion Controller algorithm (such as
TCP's congestion control <xref target="RFC5681"></xref> or
TCP-Friendly Rate Control, TFRC <xref target="RFC5348"></xref>),
because the Circuit Breaker reacts to more persistent congestion and
operates over longer timescales (i.e., the overload condition will
have persisted for a longer time before the Circuit Breaker is
triggered).</t>
<t>A Circuit Breaker that reduces the rate of a flow, MUST continue
to monitor the level of congestion and MUST further reduce the rate
if the Circuit Breaker is again triggered.</t>
<t>The reaction to a triggered Circuit Breaker MUST continue for a
period that is at least the triggering interval. Operator
intervention will usually be required to restore a flow. If an
automated response is needed to reset the trigger, then this needs
to not be immediate. The design of an automated reset mechanism
needs to be sufficiently conservative that it does not adversely
interact with other mechanisms (including other Circuit Breaker
algorithms that control traffic over a common path). It SHOULD NOT
perform an automated reset when there is evidence of continued
congestion.</t>
<t>When a Circuit Breaker is triggered, it SHOULD be regarded as an
abnormal network event. As such, this event SHOULD be logged. The
measurements that lead to triggering of the Circuit Breaker SHOULD
also be logged.</t>
<t>A Circuit Breaker requires control communication between
endpoints and/or network devices. The source and integrity of
control information (measurements and triggers) MUST be protected
from off-path attacks (<xref target="sec"></xref> ). The circuit
breaker MUST be designed to be robust to packet loss that can also
be experienced during congestion/overload. This does not imply that
it is desirable to provide reliable delivery (e.g., over TCP), since
this can incur additional delay in responding to congestion.
Appropriate mechanisms could be to duplicate control messages to
provide increased robustness to loss, or/and to regard a lack of
control traffic as an indication that excessive congestion may be
being experienced <xref
target="ID-ietf-tsvwg-RFC5405.bis"></xref>.</t>
<t>The control communication may be in-band or out-of-band. In-band
communication is RECOMMENDED when either design would be possible.
If this traffic is sent over a shared path, it is RECOMMENDED that
this control traffic is prioritized to reduce the probability of
loss under congestion. Control traffic also needs to be considered
when provisioning a network that uses a circuit breaker.<list
style="hanging">
<t hangText="in-Band:">An in-band control method SHOULD assume
that loss of control messages is an indication of potential
congestion on the path, and repeated loss ought to cause the
Circuit Breaker to be triggered. This design has the advantage
that it provides fate-sharing of the traffic flow(s) and the
control communications.</t>
<t hangText="Out-of-Band:">An out-of-band control method SHOULD
NOT trigger Circuit Breaker reaction when there is loss of
control messages (e.g., a loss of measurements). This avoids
failure amplification/propagation when the measurement and data
paths fail independently. A failure of an out-of-band
communication path SHOULD be regarded as abnormal network event
and be handled as appropriate for the network, e.g., this event
SHOULD be logged, and additional network operator action might
be appropriate, depending on the network and the traffic
involved.</t>
</list></t>
</list></t>
</section>
<section title="Other network topologies">
<t>A Circuit Breaker can be deployed in networks with topologies
different to that presented in figure 2. This section describes examples
of such usage, and possible places where functions may be
implemented.</t>
<section title="Use with a multicast control/routing protocol">
<t><figure>
<artwork><![CDATA[
+----------+ +--------+ +----------+
| Ingress | +-+ +-+ +-+ | Egress | | Egress |
| Endpoint +->+R+--+R+--+R+--+ Router |--+ Endpoint +->+
+----+-----+ +-+ +-+ +-+ +---+--+-+ +----+-----+ |
^ ^ ^ ^ | ^ | |
| | | | | | | |
+----+----+ + - - - < - - - - + | +----+----+ | Reported
| Ingress | multicast Prune | | Egress | | Ingress
| Meter | | | Meter | | Measurement
+---------+ | +----+----+ |
| | |
| +----+----+ |
| | Measure +<--+
| +----+----+
| |
| +----+----+
multicast | | Trigger |
Leave | +----+----+
Message | |
+----<----+
]]></artwork>
</figure>Figure 3: An example of a multicast CB controlling the
end-to-end path between an ingress endpoint and an egress
endpoint.</t>
<t>Figure 3 shows one example of how a multicast circuit breaker could
be implemented at a pair of multicast endpoints (e.g., to implement a
Fast-Trip Circuit Breaker, <xref target="FCB"></xref>). The ingress
endpoint (the sender that sources the multicast traffic) meters the
ingress load, generating an ingress measurement (e.g., recording
timestamped packet counts), and sends this measurement to the
multicast group together with the traffic it has measured.</t>
<t>Routers along a multicast path forward the multicast traffic
(including the ingress measurement) to all active endpoint receivers.
Each last hop (egress) router forwards the traffic to one or more
egress endpoint(s).</t>
<t>In this figure, each endpoint includes a meter that performs a
local egress load measurement. An endpoint also extracts the received
ingress measurement from the traffic, and compares the ingress and
egress measurements to determine if the Circuit Breaker ought to be
triggered. This measurement has to be robust to loss (see previous
section). If the Circuit Breaker is triggered, it generates a
multicast leave message for the egress (e.g., an IGMP or MLD message
sent to the last hop router), which causes the upstream router to
cease forwarding traffic to the egress endpoint.</t>
<t>Any multicast router that has no active receivers for a particular
multicast group will prune traffic for that group, sending a prune
message to its upstream router. This starts the process of releasing
the capacity used by the traffic and is a standard multicast routing
function (e.g., using the PIM-SM routing protocol). Each egress
operates autonomously, and the circuit breaker "reaction" is executed
by the multicast control plane (e.g., by the PIM multicast routing
protocol), requiring no explicit signalling by the circuit breaker
along the communication path used for the control messages. Note:
there is no direct communication with the Ingress, and hence a
triggered Circuit Breaker only controls traffic downstream of the
first hop router. It does not stop traffic flowing from the sender to
the first hop router; this is however the common practice for
multicast deployment.</t>
<t>The method could also be used with a multicast tunnel or subnetwork
(e.g., <xref target="SCB"></xref>, <xref target="MCB"></xref>), where
a meter at the ingress generates additional control messages to carry
the measurement data towards the egress where the egress metering is
implemented.</t>
</section>
<section title="Use with control protocols supporting pre-provisioned capacity">
<t>Some paths are provisioned using a control protocol, e.g., flows
provisioned using the Multi-Protocol Label Switching (MPLS) services,
path provisioned using the Resource reservation protocol (RSVP),
networks utilizing Software Defined Network (SDN) functions, or
admission-controlled Differentiated Services.</t>
<t>Figure 1 shows one expected use case, where in this usage a
separate device could be used to perform the measurement and trigger
functions. The reaction generated by the trigger could take the form
of a network control message sent to the ingress and/or other network
elements causing these elements to react to the Circuit Breaker.
Examples of this type of use are provided in section <xref
target="MCB"></xref>.</t>
</section>
<section title="Unidirectional Circuit Breakers over Controlled Paths">
<t>A Circuit Breaker can be used to control uni-directional UDP
traffic, providing that there is a communication path that can be used
for control messages to connect the functional components at the
Ingress and Egress. This communication path for the control messages
can exist in networks for which the traffic flow is purely
unidirectional. For example, a multicast stream that sends packets
across an Internet path and can use multicast routing to prune flows
to shed network load. Some other types of subnetwork also utilize
control protocols that can be used to control traffic flows.</t>
</section>
</section>
<section title="Examples of Circuit Breakers">
<t>There are multiple types of Circuit Breaker that could be defined for
use in different deployment cases. This section provides examples of
different types of circuit breaker:</t>
<section anchor="FCB" title="A Fast-Trip Circuit Breaker">
<t>Applications ought to use a full-featured transport (TCP, SCTP,
DCCP), and if not, application (e.g. those using UDP and its UDP-Lite
variant [RFC3828])they need to provide appropriate congestion
avoidance. <xref target="RFC2309"></xref> discusses the dangers of
congestion-unresponsive flows and states that "all UDP-based streaming
applications should incorporate effective congestion avoidance
mechanisms". Guidance for applications that do not use
congestion-controlled transports is provided in <xref
target="ID-ietf-tsvwg-RFC5405.bis"></xref>. Such mechanisms can be
designed to react on much shorter timescales than a circuit breaker,
that only observes a traffic envelope. These methods can also interact
with an application to more effectively control its sending rate.</t>
<t>A fast-trip circuit breaker is the most responsive form of Circuit
Breaker. It has a response time that is only slightly larger than that
of the traffic that it controls. It is suited to traffic with
well-understood characteristics (and could include one or more trigger
functions specifically tailored the type of traffic for which it is
designed). It is not suited to arbitrary network traffic and may be
unsuitable fro traffic aggregates, since it could prematurely trigger
(e.g., when multiple congestion-controlled flows lead to short-term
overload).</t>
<t>These mechanisms are suitable for implementation in endpoints,
where they can also compliment end-to-end congestion control methods.
A shorter response time enables these mechanisms to triggers before
other forms of circuit breaker (e.g., circuit breakers operating on
traffic aggregates at a point along the network path).</t>
<section title="A Fast-Trip Circuit Breaker for RTP">
<t>A set of fast-trip Circuit Breaker methods have been specified
for use together by a Real-time Transport Protocol (RTP) flow using
the RTP/AVP Profile <xref target="RTP-CB"></xref>. It is expected
that, in the absence of severe congestion, all RTP applications
running on best-effort IP networks will be able to run without
triggering these circuit breakers. A fast-trip RTP Circuit Breaker
is therefore implemented as a fail-safe that when triggered will
terminate RTP traffic.</t>
<t>The sender monitors reception of in-band Real Time Control
Protocol (RTCP) reception report blocks, as contained in SR or RR
packets, that convey reception quality feedback information. This is
used to measure (congestion) loss, possibly in combination with ECN
<xref target="RFC6679"></xref>.</t>
<t>The Circuit Breaker action (shutdown of the flow) is triggered
when any of the following trigger conditions are true:</t>
<t><list style="numbers">
<t>An RTP Circuit Breaker triggers on reported lack of
progress.</t>
<t>An RTP Circuit Breaker triggers when no receiver reports
messages are received.</t>
<t>An RTP Circuit Breaker uses a TFRC-style check and sets a
hard upper limit to the long-term RTP throughput (over many
RTTs).</t>
<t>An RTP Circuit Breaker includes the notion of Media
Usability. This circuit breaker is triggered when the quality of
the transported media falls below some required minimum
acceptable quality.</t>
</list></t>
</section>
</section>
<section anchor="SCB" title="A Slow-trip Circuit Breaker">
<t>A slow-trip Circuit Breaker could be implemented in an endpoint or
network device. This type of Circuit Breaker is much slower at
responding to congestion than a fast-trip Circuit Breaker and is
expected to be more common.</t>
<t>One example where a slow-trip Circuit Breaker is needed is where
flows or traffic-aggregates use a tunnel or encapsulation and the
flows within the tunnel do not all support TCP-style congestion
control (e.g., TCP, SCTP, TFRC), see <xref
target="ID-ietf-tsvwg-RFC5405.bis"></xref> section 3.1.3. A use case
is where tunnels are deployed in the general Internet (rather than
"controlled environments" within an Internet service provider or
enterprise network), especially when the tunnel could need to cross a
customer access router.</t>
</section>
<section anchor="MCB" title="A Managed Circuit Breaker">
<t>A managed Circuit Breaker is implemented in the signalling protocol
or management plane that relates to the traffic aggregate being
controlled. This type of circuit breaker is typically applicable when
the deployment is within a "controlled environment".</t>
<t>A Circuit Breaker requires more than the ability to determine that
a network path is forwarding data, or to measure the rate of a path -
which are often normal network operational functions. There is an
additional need to determine a metric for congestion on the path and
to trigger a reaction when a threshold is crossed that indicates
persistent congestion.</t>
<t>The control messages can use either in-band or out-of-band
communications.</t>
<section title="A Managed Circuit Breaker for SAToP Pseudo-Wires">
<t><xref target="RFC4553"></xref>, SAToP Pseudo-Wires (PWE3),
section 8 describes an example of a managed circuit breaker for
isochronous flows.</t>
<t>If such flows were to run over a pre-provisioned (e.g.,
Multi-Protocol Label Switching, MPLS) infrastructure, then it could
be expected that the Pseudowire (PW) would not experience
congestion, because a flow is not expected to either increase (or
decrease) their rate. If instead Pseudo-Wire traffic is multiplexed
with other traffic over the general Internet, it could experience
congestion. <xref target="RFC4553"></xref> states: "If SAToP PWs run
over a PSN providing best-effort service, they SHOULD monitor packet
loss in order to detect "severe congestion". The currently
recommended measurement period is 1 second, and the trigger operates
when there are more than three measured Severely Errored Seconds
(SES) within a period. If such a condition is detected, a SAToP PW
ought to shut down bidirectionally for some period of time...".</t>
<t>The concept was that when the packet loss ratio (congestion)
level increased above a threshold, the PW was by default disabled.
This use case considered fixed-rate transmission, where the PW had
no reasonable way to shed load.</t>
<t>The trigger needs to be set at the rate that the PW was likely to
experience a serious problem, possibly making the service
non-compliant. At this point, triggering the Circuit Breaker would
remove the traffic preventing undue impact on congestion-responsive
traffic (e.g., TCP). Part of the rationale, was that high loss
ratios typically indicated that something was "broken" and ought to
have already resulted in operator intervention, and therefore need
to trigger this intervention.</t>
<t>An operator-based response provides opportunity for other action
to restore the service quality, e.g., by shedding other loads or
assigning additional capacity, or to consciously avoid reacting to
the trigger while engineering a solution to the problem. This could
require the trigger to be sent to a third location (e.g., a network
operations centre, NOC) responsible for operation of the tunnel
ingress, rather than the tunnel ingress itself.</t>
</section>
<section title="A Managed Circuit Breaker for Pseudowires (PWs)">
<t>Pseudowires (PWs) <xref target="RFC3985"></xref> have become a
common mechanism for tunneling traffic, and may compete for network
resources both with other PWs and with non-PW traffic, such as
TCP/IP flows.</t>
<t><xref target="ID-ietf-pals-congcons"></xref> discusses congestion
conditions that can arise when PWs compete with elastic (i.e.,
congestion responsive) network traffic (e.g, TCP traffic). Elastic
PWs carrying IP traffic (see <xref target="RFC4488"></xref>) do not
raise major concerns because all of the traffic involved responds,
reducing the transmission rate when network congestion is
detected.</t>
<t>In contrast, inelastic PWs (e.g., a fixed bandwidth Time Division
Multiplex, TDM) <xref target="RFC4553"></xref> <xref
target="RFC5086"></xref> <xref target="RFC5087"></xref>) have the
potential to harm congestion responsive traffic or to contribute to
excessive congestion because inelastic PWs do not adjust their
transmission rate in response to congestion. <xref
target="ID-ietf-pals-congcons"></xref> analyses TDM PWs, with an
initial conclusion that a TDM PW operating with a degree of loss
that may result in congestion-related problems is also operating
with a degree of loss that results in an unacceptable TDM service.
For that reason, the draft suggests that a managed circuit breaker
that shuts down a PW when it persistently fails to deliver
acceptable TDM service is a useful means for addressing these
congestion concerns.</t>
</section>
</section>
</section>
<section title="Examples where circuit breakers may not be needed. ">
<t>A Circuit Breaker is not required for a single Congestion
Controller-controlled flow using TCP, SCTP, TFRC, etc. In these cases,
the Congestion Control methods are already designed to prevent
persistent congestion.</t>
<section title="CBs over pre-provisioned Capacity">
<t>One common question is whether a Circuit Breaker is needed when a
tunnel is deployed in a private network with pre-provisioned
capacity.</t>
<t>In this case, compliant traffic that does not exceed the
provisioned capacity ought not to result in persistent congestion. A
Circuit Breaker will hence only be triggered when there is
non-compliant traffic. It could be argued that this event ought never
to happen - but it could also be argued that the Circuit Breaker
equally ought never to be triggered. If a Circuit Breaker were to be
implemented, it will provide an appropriate response if persistent
congestion occurs in an operational network.</t>
<t>Implementing a Circuit Breaker will not reduce the performance of
the flows, but in the event that persistent congestion occurs it
protects network traffic that shares network capacity with these
flows. A Circuit Breaker also could be used to protect other sharing
network traffic from a failure that causes the Circuit Breaker traffic
to be routed over a non-pre-provisioned path.</t>
</section>
<section title="CBs with tunnels carrying Congestion-Controlled Traffic">
<t>IP-based traffic is generally assumed to be congestion-controlled,
i.e., it is assumed that the transport protocols generating IP-based
traffic at the sender already employ mechanisms that are sufficient to
address congestion on the path <xref
target="ID-ietf-tsvwg-RFC5405.bis"></xref>. A question therefore
arises when people deploy a tunnel that is thought to only carry an
aggregate of TCP (or some other Congestion Controller-controlled)
traffic: Is there advantage in this case in using a Circuit
Breaker?</t>
<t>For sure, traffic in a such a tunnel will respond to congestion.
However, the answer to the question is not always obvious, because the
overall traffic formed by an aggregate of flows that implement a
Congestion Controller mechanism does not necessarily prevent
persistent congestion. For instance, most Congestion Controller
mechanisms require long-lived flows to react to reduce the rate of a
flow, an aggregate of many short flows could result in many
terminating before they experience congestion. It is also often
impossible for a tunnel service provider to know that the tunnel only
contains CC-controlled traffic (e.g., Inspecting packet headers could
not be possible). The important thing to note is that if the aggregate
of the traffic does not result in persistent congestion (impacting
other flows), then the Circuit Breaker will not trigger. This is the
expected case in this context - so implementing a Circuit Breaker will
not reduce performance of the tunnel, but in the event that persistent
congestion occurs this protects other network traffic that shares
capacity with the tunnel traffic.</t>
</section>
<section title="CBs with Uni-directional Traffic and no Control Path">
<t>A one-way forwarding path could have no associated communication
path for sending control messages, and therefore cannot be controlled
using an automated process. This service could be provided using a
path that has dedicated capacity and does not share this capacity with
other elastic Internet flows (i.e., flows that vary their rate).</t>
<t>A way to mitigate the impact on other flows when capacity could be
shared is to manage the traffic envelope by using ingress
policing.</t>
<t>Supporting this type of traffic in the general Internet requires
operator monitoring to detect and respond to persistent
congestion.</t>
</section>
</section>
<section anchor="sec" title="Security Considerations" toc="include">
<t>All Circuit Breaker mechanisms rely upon coordination between the
ingress and egress meters and communication with the trigger function.
This is usually achieved by passing network control information (or
protocol messages) across the network. Timely operation of a circuit
breaker depends on the choice of measurement period. If the receiver has
an interval that is overly long, then the responsiveness of the circuit
breaker decreases. This impacts the ability of the circuit breaker to
detect and react to congestion.</t>
<t>Mechanisms need to be implemented to prevent attacks on the network
control information that would result in Denial of Service (DoS). The
source and integrity of control information (measurements and triggers)
MUST be protected from off-path attacks. Without protection, it could be
trivial for an attacker to inject packets with values that could
prematurely trigger a circuit breaker resulting in DoS. Simple
protection can be provided by using a randomized source port, or
equivalent field in the packet header (such as the RTP SSRC value and
the RTP sequence number) expected not to be known to an off-path
attacker. Stronger protection can be achieved using a secure
authentication protocol.</t>
<t>Transmission of network control information consumes network
capacity. This control traffic needs to be considered in the design of a
Circuit Breaker and could potentially add to network congestion. If this
traffic is sent over a shared path, it is RECOMMENDED that this control
traffic is prioritized to reduce the probability of loss under
congestion. Control traffic also needs to be considered when
provisioning a network that uses a circuit breaker.</t>
<t>The circuit breaker MUST be designed to be robust to packet loss that
can also be experienced during congestion/overload. Loss of control
messages could be a side-effect of a congested network, but also could
arise from other causes <xref target="Require"></xref>.</t>
<t>The security implications depend on the design of the mechanisms, the
type of traffic being controlled and the intended deployment scenario.
Each design of a Circuit Breaker MUST therefore evaluate whether the
particular circuit breaker mechanism has new security implications.</t>
</section>
<section title="IANA Considerations" toc="include">
<t>This document makes no request from IANA.</t>
</section>
<section title="Acknowledgments">
<t>There are many people who have discussed and described the issues
that have motivated this draft. Contributions and comments included:
Lars Eggert, Colin Perkins, David Black, Matt Mathis, Andrew McGregor,
and Bob Briscoe. This work was part-funded by the European Community
under its Seventh Framework Programme through the Reducing Internet
Transport Latency (RITE) project (ICT-317700).</t>
</section>
<section title="Revision Notes">
<t>XXX RFC-Editor: Please remove this section prior to publication
XXX</t>
<t>Draft 00</t>
<t>This was the first revision. Help and comments are greatly
appreciated.</t>
<t>Draft 01</t>
<t>Contained clarifications and changes in response to received
comments, plus addition of diagram and definitions. Comments are
welcome.</t>
<t>WG Draft 00</t>
<t>Approved as a WG work item on 28th Aug 2014.</t>
<t>WG Draft 01</t>
<t>Incorporates feedback after Dallas IETF TSVWG meeting. This version
is thought ready for WGLC comments. Definitions of abbreviations.</t>
<t>WG Draft 02</t>
<t>Minor fixes for typos. Rewritten security considerations section.</t>
<t>WG Draft 03</t>
<t>Updates following WGLC comments (see TSV mailing list). Comments from
C Perkins; D Black and off-list feedback.</t>
<t>A clear recommendation of intended scope.</t>
<t>Changes include: Improvement of language on timescales and minimum
measurement period; clearer articulation of endpoint and multicast
examples - with new diagrams; separation of the controlled network case;
updated text on position of trigger function; corrections to RTP-CB
text; clarification of loss v ECN metrics; checks against submission
checklist 9use of keywords, added meters to diagrams).</t>
<t>WG Draft 04</t>
<t>Added section on PW CB for TDM - a newly adopted draft (D.
Black).</t>
<t>WG Draft 05</t>
<t>Added clarifications requested during AD review.</t>
<t>WG Draft 06</t>
<t>Fixed some remaining typos.</t>
<t>Update following detailed review by Bob Briscoe, and comments by D.
Black.</t>
<t>WG Draft 07</t>
<t>Updated text on the response to lack of meter measurements with
managed circuit breakers.</t>
</section>
</middle>
<!-- *****BACK MATTER ***** -->
<back>
<!-- -->
<references title="Normative References">
<?rfc sortrefs="yes"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2119.xml"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.3168.xml"
?>
<reference anchor="ID-ietf-tsvwg-RFC5405.bis">
<front>
<title>UDP Usage Guidelines (Work-in-Progress)</title>
<author fullname="Lars" initials="L" surname="Eggert">
<organization></organization>
<address>
<postal>
<street></street>
<city></city>
<region></region>
<code></code>
<country></country>
</postal>
<phone></phone>
<facsimile></facsimile>
<email></email>
<uri></uri>
</address>
</author>
<author fullname="Gorry" initials="G" surname="Fairhurst">
<organization></organization>
<address>
<postal>
<street></street>
<city></city>
<region></region>
<code></code>
<country></country>
</postal>
<phone></phone>
<facsimile></facsimile>
<email></email>
<uri></uri>
</address>
</author>
<author fullname="Greg" initials="G" surname="Shepherd">
<organization></organization>
</author>
<date year="2015" />
</front>
</reference>
</references>
<references title="Informative References">
<reference anchor="Jacobsen88">
<front>
<title>Congestion Avoidance and Control", SIGCOMM Symposium
proceedings on Communications architectures and protocols</title>
<author fullname="Jacobson, V.">
<organization>European Telecommunication Standards, Institute
(ETSI)</organization>
</author>
<date month="August" year="1998" />
</front>
</reference>
<reference anchor="RTP-CB">
<front>
<title>Multimedia Congestion Control: Circuit Breakers for Unicast
RTP Sessions</title>
<author fullname="C. S. Perkins" surname="Perkins">
<organization></organization>
<address>
<postal>
<street></street>
<city></city>
<region></region>
<code></code>
<country></country>
</postal>
<phone></phone>
<facsimile></facsimile>
<email></email>
<uri></uri>
</address>
</author>
<author fullname="V. Singh" surname="Singh">
<organization></organization>
</author>
<date month="February" year="2014" />
</front>
</reference>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.1112.xml"
?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2309.xml"
?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2914.xml"
?>
<?rfc ?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.3985.xml"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4488.xml"?>
<?rfc ?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4553.xml"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5086.xml"
?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5087.xml"
?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5348.xml"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5681.xml"?>
<?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.6679.xml"?>
<reference anchor="ID-ietf-pals-congcons">
<front>
<title>Pseudowire Congestion Considerations
(Work-in-Progress)</title>
<author fullname="Yaakov" initials="YJ" surname="Stein">
<organization></organization>
<address>
<postal>
<street></street>
<city></city>
<region></region>
<code></code>
<country></country>
</postal>
<phone></phone>
<facsimile></facsimile>
<email></email>
<uri></uri>
</address>
</author>
<author fullname="David" initials="D" surname="Black">
<organization></organization>
<address>
<postal>
<street></street>
<city></city>
<region></region>
<code></code>
<country></country>
</postal>
<phone></phone>
<facsimile></facsimile>
<email></email>
<uri></uri>
</address>
</author>
<author fullname="Bob" initials="B" surname="Briscoe">
<organization></organization>
</author>
<date year="2015" />
</front>
</reference>
<?rfc ?>
</references>
</back>
</rfc>