One document matched: draft-ietf-nvo3-arch-08.xml
<?xml version="1.0" encoding="US-ASCII"?>
<!-- This template is for creating an Internet Draft using xml2rfc,
which is available here: http://xml.resource.org. -->
<!DOCTYPE rfc SYSTEM "rfc2629.dtd">
<?xml-stylesheet type='text/xsl' href='rfc2629.xslt' ?>
<!-- used by XSLT processors -->
<!-- For a complete list and description of processing instructions (PIs),
please see http://xml.resource.org/authoring/README.html. -->
<!-- Below are generally applicable Processing Instructions (PIs) that most I-Ds might want to use.
(Here they are set differently than their defaults in xml2rfc v1.32) -->
<?rfc strict="no" ?>
<!-- give errors regarding ID-nits and DTD validation -->
<!-- control the table of contents (ToC) -->
<?rfc toc="yes"?>
<!-- generate a ToC -->
<?rfc tocdepth="4"?>
<!-- the number of levels of subsections in ToC. default: 3 -->
<!-- control references -->
<?rfc symrefs="yes"?>
<!-- use symbolic references tags, i.e, [RFC2119] instead of [1] -->
<?rfc sortrefs="yes" ?>
<!-- sort the reference entries alphabetically -->
<!-- control vertical white space
(using these PIs as follows is recommended by the RFC Editor) -->
<?rfc compact="yes" ?>
<!-- do not start each main section on a new page -->
<?rfc subcompact="no" ?>
<!-- keep one blank line between list items -->
<!-- end of list of popular I-D processing instructions -->
<rfc category="info" docName="draft-ietf-nvo3-arch-08" ipr="trust200902">
<!-- category values: std, bcp, info, exp, and historic
ipr values: full3667, noModification3667, noDerivatives3667
you can add the attributes updates="NNNN" and obsoletes="NNNN"
they will automatically be output with "(if approved)" -->
<!-- ***** FRONT MATTER ***** -->
<front>
<!-- The abbreviated title is used in the page header - it is only necessary if the
full title is longer than 39 characters -->
<title abbrev="NVO3 Architecture">An Architecture for Data Center Network
Virtualization Overlays (NVO3)</title>
<!-- add 'role="editor"' below for the editors if appropriate -->
<!-- Another author who claims to be an editor -->
<author fullname="David Black" initials="D." surname="Black">
<organization>Dell EMC</organization>
<address>
<email>david.black@dell.com</email>
</address>
</author>
<author fullname="Jon Hudson" initials="J." surname="Hudson">
<organization>Independent</organization>
<address>
<email>jon.hudson@gmail.com</email>
</address>
</author>
<author fullname="Lawrence Kreeger" initials="L." surname="Kreeger">
<organization>Cisco</organization>
<address>
<email>kreeger@cisco.com</email>
</address>
</author>
<author fullname="Marc Lasserre" initials="M." surname="Lasserre">
<organization>Independent</organization>
<address>
<email>mmlasserre@gmail.com</email>
</address>
</author>
<author fullname="Thomas Narten" initials="T." surname="Narten">
<organization>IBM</organization>
<address>
<email>narten@us.ibm.com</email>
</address>
</author>
<date month="September" year="2016"/>
<!-- If the month and year are both specified and are the current ones, xml2rfc will fill
in the current day for you. If only the current year is specified, xml2rfc will fill
in the current day and month for you. If the year is not the current one, it is
necessary to specify at least a month (xml2rfc assumes day="1" if not specified for the
purpose of calculating the expiry date). With drafts it is normally sufficient to
specify just the year. -->
<!-- Meta-data Declarations -->
<area>General</area>
<workgroup>Internet Engineering Task Force</workgroup>
<!-- WG name at the upperleft corner of the doc,
IETF is fine for individual submissions.
If this element is not present, the default is "Network Working Group",
which is used by the RFC Editor as a nod to the history of the IETF. -->
<keyword>template</keyword>
<!-- Keywords will be incorporated into HTML output
files in a meta tag but they have no effect on text or nroff
output. If you submit your draft to the RFC Editor, the
keywords will be used for the search engine. -->
<abstract>
<t>This document presents a high-level overview architecture for
building data center network virtualization overlay (NVO3) networks. The
architecture is given at a high-level, showing the major components of
an overall system. An important goal is to divide the space into
individual smaller components that can be implemented independently with
clear inter-component interfaces and interactions. It should be possible
to build and implement individual components in isolation and have them
interoperate with other independently implemented components. That way,
implementers have flexibility in implementing individual components and
can optimize and innovate within their respective components without
requiring changes to other components.</t>
</abstract>
</front>
<middle>
<section title="Introduction">
<t>This document presents a high-level architecture for building data
center network virtualization overlay (NVO3) networks. The architecture
is given at a high-level, showing the major components of an overall
system. An important goal is to divide the space into smaller individual
components that can be implemented independently with clear
inter-component interfaces and interactions. It should be possible to
build and implement individual components in isolation and have them
interoperate with other independently implemented components. That way,
implementers have flexibility in implementing individual components and
can optimize and innovate within their respective components without
requiring changes to other components.</t>
<t>The motivation for overlay networks is given in "Problem Statement:
Overlays for Network Virtualization" <xref target="RFC7364"/>.
"Framework for DC Network Virtualization" <xref target="RFC7365"/>
provides a framework for discussing overlay networks generally and the
various components that must work together in building such systems.
This document differs from the framework document in that it doesn't
attempt to cover all possible approaches within the general design
space. Rather, it describes one particular approach that the NVO3 WG has
focused on.</t>
</section>
<section title="Terminology">
<t>This document uses the same terminology as <xref target="RFC7365"/>.
In addition, the following terms are used:</t>
<t><list style="hanging">
<t hangText="NV Domain">A Network Virtualization Domain is an
administrative construct that defines a Network Virtualization
Authority (NVA), the set of Network Virtualization Edges (NVEs)
associated with that NVA, and the set of virtual networks the NVA
manages and supports. NVEs are associated with a (logically
centralized) NVA, and an NVE supports communication for any of the
virtual networks in the domain.</t>
<t hangText="NV Region">A region over which information about a set
of virtual networks is shared. The degenerate case of a single NV
Domain corresponds to an NV region corresponding to that domain. The
more interesting case occurs when two or more NV Domains share
information about part or all of a set of virtual networks that they
manage. Two NVAs share information about particular virtual networks
for the purpose of supporting connectivity between tenants located
in different NV Domains. NVAs can share information about an entire
NV domain, or just individual virtual networks.</t>
<t hangText="Tenant System Interface (TSI)">Interface to a Virtual
Network as presented to a Tenant System (TS, see <xref
target="RFC7365"/>). The TSI logically connects to the NVE via a
Virtual Access Point (VAP). To the Tenant System, the TSI is like a
Network Interface Card (NIC); the TSI presents itself to a Tenant
System as a normal network interface.</t>
<t hangText="VLAN">Unless stated otherwise, the terms VLAN and VLAN
Tag are used in this document to denote a C-VLAN <xref
target="IEEE-802.1Q"/> and the terms are used interchangeably to
improve readability.</t>
</list></t>
</section>
<section title="Background">
<t>Overlay networks are an approach for providing network virtualization
services to a set of Tenant Systems (TSs) <xref target="RFC7365"/>. With
overlays, data traffic between tenants is tunneled across the underlying
data center's IP network. The use of tunnels provides a number of
benefits by decoupling the network as viewed by tenants from the
underlying physical network across which they communicate. Additional
discussion of some NVO3 use cases can be found in <xref
target="I-D.ietf-nvo3-use-case"/>.</t>
<t>Tenant Systems connect to Virtual Networks (VNs), with each VN having
associated attributes defining properties of the network, such as the
set of members that connect to it. Tenant Systems connected to a virtual
network typically communicate freely with other Tenant Systems on the
same VN, but communication between Tenant Systems on one VN and those
external to the VN (whether on another VN or connected to the Internet)
is carefully controlled and governed by policy. The NVO3 architecture
does not impose any restrictions to the application of policy controls
even within a VN.</t>
<t>A Network Virtualization Edge (NVE) <xref target="RFC7365"/> is the
entity that implements the overlay functionality. An NVE resides at the
boundary between a Tenant System and the overlay network as shown in
<xref target="nvo3-reference-model"/>. An NVE creates and maintains
local state about each Virtual Network for which it is providing service
on behalf of a Tenant System.</t>
<figure anchor="nvo3-reference-model"
title="NVO3 Generic Reference Model">
<artwork name="nvo3-reference-model"><![CDATA[
+--------+ +--------+
| Tenant +--+ +----| Tenant |
| System | | (') | System |
+--------+ | ................ ( ) +--------+
| +-+--+ . . +--+-+ (_)
| | NVE|--. .--| NVE| |
+--| | . . | |---+
+-+--+ . . +--+-+
/ . .
/ . L3 Overlay . +--+-++--------+
+--------+ / . Network . | NVE|| Tenant |
| Tenant +--+ . .- -| || System |
| System | . . +--+-++--------+
+--------+ ................
|
+----+
| NVE|
| |
+----+
|
|
=====================
| |
+--------+ +--------+
| Tenant | | Tenant |
| System | | System |
+--------+ +--------+
]]></artwork>
</figure>
<t>The following subsections describe key aspects of an overlay system
in more detail. <xref target="nvo3-service"/> describes the service
model (Ethernet vs. IP) provided to Tenant Systems. <xref
target="nve-section"/> describes NVEs in more detail. <xref
target="nva-intro"/> introduces the Network Virtualization Authority,
from which NVEs obtain information about virtual networks. <xref
target="background-orchestration"/> provides background on Virtual
Machine (VM) orchestration systems and their use of virtual
networks.</t>
<section anchor="nvo3-service" title="VN Service (L2 and L3)">
<t>A Virtual Network provides either L2 or L3 service to connected
tenants. For L2 service, VNs transport Ethernet frames, and a Tenant
System is provided with a service that is analogous to being connected
to a specific L2 C-VLAN. L2 broadcast frames are generally delivered
to all (and multicast frames delivered to a subset of) the other
Tenant Systems on the VN. To a Tenant System, it appears as if they
are connected to a regular L2 Ethernet link. Within the NVO3
architecture, tenant frames are tunneled to remote NVEs based on the
MAC addresses of the frame headers as originated by the Tenant System.
On the underlay, NVO3 packets are forwarded between NVEs based on the
outer addresses of tunneled packets.</t>
<t>For L3 service, VNs are routed networks that transport IP
datagrams, and a Tenant System is provided with a service that
supports only IP traffic. Within the NVO3 architecture, tenant frames
are tunneled to remote NVEs based on the IP addresses of the packet
originated by the Tenant System; any L2 destination addresses provided
by Tenant Systems are effectively ignored by the NVEs and overlay
network. For L3 service, the Tenant System will be configured with an
IP subnet that is effectively a point-to-point link, i.e., having only
the Tenant System and a next-hop router address on it.</t>
<t>L2 service is intended for systems that need native L2 Ethernet
service and the ability to run protocols directly over Ethernet (i.e.,
not based on IP). L3 service is intended for systems in which all the
traffic can safely be assumed to be IP. It is important to note that
whether an NVO3 network provides L2 or L3 service to a Tenant System,
the Tenant System does not generally need to be aware of the
distinction. In both cases, the virtual network presents itself to the
Tenant System as an L2 Ethernet interface. An Ethernet interface is
used in both cases simply as a widely supported interface type that
essentially all Tenant Systems already support. Consequently, no
special software is needed on Tenant Systems to use an L3 vs. an L2
overlay service.</t>
<t>NVO3 can also provide a combined L2 and L3 service to tenants. A
combined service provides L2 service for intra-VN communication, but
also provides L3 service for L3 traffic entering or leaving the VN.
Architecturally, the handling of a combined L2/L3 service within the
NVO3 architecture is intended to match what is commonly done today in
non-overlay environments by devices providing a combined bridge/router
service. With combined service, the virtual network itself retains the
semantics of L2 service and all traffic is processed according to its
L2 semantics. In addition, however, traffic requiring IP processing is
also processed at the IP level.</t>
<t>The IP processing for a combined service can be implemented on a
standalone device attached to the virtual network (e.g., an IP router)
or implemented locally on the NVE (see Section 5.4 on Distributed
Gateways). For unicast traffic, NVE implementation of a combined
service may result in a packet being delivered to another Tenant
System attached to the same NVE (on either the same or a different VN)
or tunneled to a remote NVE, or even forwarded outside the NV domain.
For multicast or broadcast packets, the combination of NVE L2 and L3
processing may result in copies of the packet receiving both L2 and L3
treatments to realize delivery to all of the destinations involved.
This distributed NVE implementation of IP routing results in the same
network delivery behavior as if the L2 processing of the packet
included delivery of the packet to an IP router attached to the L2 VN
as a Tenant System, with the router having additional network
attachments to other networks, either virtual or not.</t>
<section anchor="vlan-tags-section" title="VLAN Tags in L2 Service">
<t>An NVO3 L2 virtual network service may include encapsulated L2
VLAN tags provided by a Tenant System, but does not use encapsulated
tags in deciding where and how to forward traffic. Such VLAN tags
can be passed through, so that Tenant Systems that send or expect to
receive them can be supported as appropriate.</t>
<t>The processing of VLAN tags that an NVE receives from a TS is
controlled by settings associated with the VAP. Just as in the case
with ports on Ethernet switches, a number of settings are possible.
For example, C-TAGs can be passed through transparently, they could
always be stripped upon receipt from a Tenant System, they could be
compared against a list of explicitly configured tags, etc.</t>
<t>Note that that there are additional considerations when VLAN tags
are used to identify both the VN and a Tenant System VLAN within
that VN, as described in <xref target="vlan-tags-split-nve"/>
below.</t>
</section>
<section anchor="packet-lifetime-considerations"
title="Packet Lifetime Considerations">
<t>For L3 service, Tenant Systems should expect the IPv4 TTL (Time
to Live) or IPv6 Hop Limit in the packets they send to be
decremented by at least 1. For L2 service, neither the TTL nor the
Hop Limit (when the packet is IP) are modified. The underlay network
manages TTLs and Hop Limits in the outer IP encapsulation - the
values in these fields could be independent from or related to the
values in the same fields of tenant IP packets.</t>
</section>
</section>
<section anchor="nve-section" title="Network Virtualization Edge (NVE)">
<t>Tenant Systems connect to NVEs via a Tenant System Interface (TSI).
The TSI logically connects to the NVE via a Virtual Access Point (VAP)
and each VAP is associated with one Virtual Network as shown in <xref
target="nve-reference-model"/>. To the Tenant System, the TSI is like
a NIC; the TSI presents itself to a Tenant System as a normal network
interface. On the NVE side, a VAP is a logical network port (virtual
or physical) into a specific virtual network. Note that two different
Tenant Systems (and TSIs) attached to a common NVE can share a VAP
(e.g., TS1 and TS2 in <xref target="nve-reference-model"/>) so long as
they connect to the same Virtual Network.</t>
<figure anchor="nve-reference-model" title="NVE Reference Model">
<artwork name="nve-reference-model"><![CDATA[
| Data Center Network (IP) |
| |
+-----------------------------------------+
| |
| Tunnel Overlay |
+------------+---------+ +---------+------------+
| +----------+-------+ | | +-------+----------+ |
| | Overlay Module | | | | Overlay Module | |
| +---------+--------+ | | +---------+--------+ |
| | | | | |
NVE1 | | | | | | NVE2
| +--------+-------+ | | +--------+-------+ |
| | VNI1 VNI2 | | | | VNI1 VNI2 | |
| +-+----------+---+ | | +-+-----------+--+ |
| | VAP1 | VAP2 | | | VAP1 | VAP2|
+----+----------+------+ +----+-----------+-----+
| | | |
|\ | | |
| \ | | /|
-------+--\-------+-------------------+---------/-+-------
| \ | Tenant | / |
TSI1 |TSI2\ | TSI3 TSI1 TSI2/ TSI3
+---+ +---+ +---+ +---+ +---+ +---+
|TS1| |TS2| |TS3| |TS4| |TS5| |TS6|
+---+ +---+ +---+ +---+ +---+ +---+
]]></artwork>
</figure>
<t>The Overlay Module performs the actual encapsulation and
decapsulation of tunneled packets. The NVE maintains state about the
virtual networks it is a part of so that it can provide the Overlay
Module with such information as the destination address of the NVE to
tunnel a packet to and the Context ID that should be placed in the
encapsulation header to identify the virtual network that a tunneled
packet belongs to.</t>
<t>On the data center network side, the NVE sends and receives native
IP traffic. When ingressing traffic from a Tenant System, the NVE
identifies the egress NVE to which the packet should be sent, adds an
overlay encapsulation header, and sends the packet on the underlay
network. When receiving traffic from a remote NVE, an NVE strips off
the encapsulation header, and delivers the (original) packet to the
appropriate Tenant System. When the source and destination Tenant
System are on the same NVE, no encapsulation is needed and the NVE
forwards traffic directly.</t>
<t>Conceptually, the NVE is a single entity implementing the NVO3
functionality. In practice, there are a number of different
implementation scenarios, as described in detail in <xref
target="nve-section2"/>.</t>
</section>
<section anchor="nva-intro"
title="Network Virtualization Authority (NVA)">
<t>Address dissemination refers to the process of learning, building
and distributing the mapping/forwarding information that NVEs need in
order to tunnel traffic to each other on behalf of communicating
Tenant Systems. For example, in order to send traffic to a remote
Tenant System, the sending NVE must know the destination NVE for that
Tenant System.</t>
<t>One way to build and maintain mapping tables is to use learning, as
802.1 bridges do <xref target="IEEE-802.1Q"/>. When forwarding traffic
to multicast or unknown unicast destinations, an NVE could simply
flood traffic. While flooding works, it can lead to traffic hot spots
and can lead to problems in larger networks (e.g., excessive amounts
of flooded traffic).</t>
<t>Alternatively, to reduce the scope of where flooding must take
place, or to eliminate it all together, NVEs can make use of a Network
Virtualization Authority (NVA). An NVA is the entity that provides
address mapping and other information to NVEs. NVEs interact with an
NVA to obtain any required address mapping information they need in
order to properly forward traffic on behalf of tenants. The term NVA
refers to the overall system, without regards to its scope or how it
is implemented. NVAs provide a service, and NVEs access that service
via an NVE-to-NVA protocol as discussed in <xref
target="nve-to-nva"/>.</t>
<t>Even when an NVA is present, Ethernet bridge MAC address learning
could be used as a fallback mechanism, should the NVA be unable to
provide an answer or for other reasons. This document does not
consider flooding approaches in detail, as there are a number of
benefits in using an approach that depends on the presence of an
NVA.</t>
<t>For the rest of this document, it is assumed that an NVA exists and
will be used. NVAs are discussed in more detail in <xref
target="nva-section"/>.</t>
</section>
<section anchor="background-orchestration"
title="VM Orchestration Systems">
<t>VM orchestration systems manage server virtualization across a set
of servers. Although VM management is a separate topic from network
virtualization, the two areas are closely related. Managing the
creation, placement, and movement of VMs also involves creating,
attaching to and detaching from virtual networks. A number of existing
VM orchestration systems have incorporated aspects of virtual network
management into their systems.</t>
<t>Note also, that although this section uses the term "VM" and
"hypervisor" throughout, the same issues apply to other virtualization
approaches, including Linux Containers (LXC), BSD Jails, Network
Service Appliances as discussed in Section 5.1, etc.. From an NVO3
perspective, it should be assumed that where the document uses the
term "VM" and "hypervisor", the intention is that the discussion also
applies to other systems, where, e.g., the host operating system plays
the role of the hypervisor in supporting virtualization, and a
container plays the equivalent role as a VM.</t>
<t>When a new VM image is started, the VM orchestration system
determines where the VM should be placed, interacts with the
hypervisor on the target server to load and start the VM and controls
when a VM should be shutdown or migrated elsewhere. VM orchestration
systems also have knowledge about how a VM should connect to a
network, possibly including the name of the virtual network to which a
VM is to connect. The VM orchestration system can pass such
information to the hypervisor when a VM is instantiated. VM
orchestration systems have significant (and sometimes global)
knowledge over the domain they manage. They typically know on what
servers a VM is running, and meta data associated with VM images can
be useful from a network virtualization perspective. For example, the
meta data may include the addresses (MAC and IP) the VMs will use and
the name(s) of the virtual network(s) they connect to.</t>
<t>VM orchestration systems run a protocol with an agent running on
the hypervisor of the servers they manage. That protocol can also
carry information about what virtual network a VM is associated with.
When the orchestrator instantiates a VM on a hypervisor, the
hypervisor interacts with the NVE in order to attach the VM to the
virtual networks it has access to. In general, the hypervisor will
need to communicate significant VM state changes to the NVE. In the
reverse direction, the NVE may need to communicate network
connectivity information back to the hypervisor. Examples of deployed
VM orchestration systems include VMware's vCenter Server, Microsoft's
System Center Virtual Machine Manager, and systems based on OpenStack
and its associated plugins (e.g., Nova and Neutron). Each can pass
information about what virtual networks a VM connects to down to the
hypervisor. The protocol used between the VM orchestration system and
hypervisors is generally proprietary.</t>
<t>It should be noted that VM orchestration systems may not have
direct access to all networking related information a VM uses. For
example, a VM may make use of additional IP or MAC addresses that the
VM management system is not aware of.</t>
</section>
</section>
<section anchor="nve-section2" title="Network Virtualization Edge (NVE)">
<t>As introduced in <xref target="nve-section"/> an NVE is the entity
that implements the overlay functionality. This section describes NVEs
in more detail. An NVE will have two external interfaces:</t>
<t><list style="hanging">
<t hangText="Tenant System Facing:">On the Tenant System facing
side, an NVE interacts with the hypervisor (or equivalent entity) to
provide the NVO3 service. An NVE will need to be notified when a
Tenant System "attaches" to a virtual network (so it can validate
the request and set up any state needed to send and receive traffic
on behalf of the Tenant System on that VN). Likewise, an NVE will
need to be informed when the Tenant System "detaches" from the
virtual network so that it can reclaim state and resources
appropriately.</t>
<t hangText="Data Center Network Facing:">On the data center network
facing side, an NVE interfaces with the data center underlay
network, sending and receiving tunneled packets to and from the
underlay. The NVE may also run a control protocol with other
entities on the network, such as the Network Virtualization
Authority.</t>
</list></t>
<section title="NVE Co-located With Server Hypervisor">
<t>When server virtualization is used, the entire NVE functionality
will typically be implemented as part of the hypervisor and/or virtual
switch on the server. In such cases, the Tenant System interacts with
the hypervisor and the hypervisor interacts with the NVE. Because the
interaction between the hypervisor and NVE is implemented entirely in
software on the server, there is no "on-the-wire" protocol between
Tenant Systems (or the hypervisor) and the NVE that needs to be
standardized. While there may be APIs between the NVE and hypervisor
to support necessary interaction, the details of such an API are not
in-scope for the NVO3 WG at the time of publication of this memo.</t>
<t>Implementing NVE functionality entirely on a server has the
disadvantage that server CPU resources must be spent implementing the
NVO3 functionality. Experimentation with overlay approaches and
previous experience with TCP and checksum adapter offloads suggests
that offloading certain NVE operations (e.g., encapsulation and
decapsulation operations) onto the physical network adapter can
produce performance advantages. As has been done with checksum and/or
TCP server offload and other optimization approaches, there may be
benefits to offloading common operations onto adapters where possible.
Just as important, the addition of an overlay header can disable
existing adapter offload capabilities that are generally not prepared
to handle the addition of a new header or other operations associated
with an NVE.</t>
<t>While the exact details of how to split the implementation of
specific NVE functionality between a server and its network adapters
is an implementation matter and outside the scope of IETF
standardization, the NVO3 architecture should be cognizant of and
support such separation. Ideally, it may even be possible to bypass
the hypervisor completely on critical data path operations so that
packets between a Tenant System and its VN can be sent and received
without having the hypervisor involved in each individual packet
operation.</t>
</section>
<section anchor="split-nve" title="Split-NVE">
<t>Another possible scenario leads to the need for a split NVE
implementation. An NVE running on a server (e.g. within a hypervisor)
could support NVO3 service towards the tenant, but not perform all NVE
functions (e.g., encapsulation) directly on the server; some of the
actual NVO3 functionality could be implemented on (i.e., offloaded to)
an adjacent switch to which the server is attached. While one could
imagine a number of link types between a server and the NVE, one
simple deployment scenario would involve a server and NVE separated by
a simple L2 Ethernet link. A more complicated scenario would have the
server and NVE separated by a bridged access network, such as when the
NVE resides on a top of rack (ToR) switch, with an embedded switch
residing between servers and the ToR switch.</t>
<t>For the split NVE case, protocols will be needed that allow the
hypervisor and NVE to negotiate and setup the necessary state so that
traffic sent across the access link between a server and the NVE can
be associated with the correct virtual network instance. Specifically,
on the access link, traffic belonging to a specific Tenant System
would be tagged with a specific VLAN C-TAG that identifies which
specific NVO3 virtual network instance it connects to. The
hypervisor-NVE protocol would negotiate which VLAN C-TAG to use for a
particular virtual network instance. More details of the protocol
requirements for functionality between hypervisors and NVEs can be
found in <xref target="I-D.ietf-nvo3-nve-nva-cp-req"/>.</t>
<section anchor="vlan-tags-split-nve"
title="Tenant VLAN handling in Split-NVE Case">
<t>Preserving tenant VLAN tags across an NVO3 VN as described in
<xref target="vlan-tags-section"/> poses additional complications in
the split-NVE case. The portion of the NVE that performs the
encapsulation function needs access to the specific VLAN tags that
the Tenant System is using in order to include them in the
encapsulated packet. When an NVE is implemented entirely within the
hypervisor, the NVE has access to the complete original packet
(including any VLAN tags) sent by the tenant. In the split-NVE case,
however, the VLAN tag used between the hypervisor and offloaded
portions of the NVE normally only identifies the specific VN that
traffic belongs to. In order to allow a tenant to preserve VLAN
information from end to end between Tenant Systems in the split-NVE
case, additional mechanisms would be needed (e.g., carry an
additional VLAN tag by carrying both a C-Tag and an S-Tag as
specified in <xref target="IEEE-802.1Q"/> where the C-Tag identifies
the tenant VLAN end-to-end and the S-Tag identifies the VN locally
between each Tenant System and the corresponding NVE).</t>
</section>
</section>
<section anchor="nve-state" title="NVE State">
<t>NVEs maintain internal data structures and state to support the
sending and receiving of tenant traffic. An NVE may need some or all
of the following information:</t>
<t><list style="numbers">
<t>An NVE keeps track of which attached Tenant Systems are
connected to which virtual networks. When a Tenant System attaches
to a virtual network, the NVE will need to create or update local
state for that virtual network. When the last Tenant System
detaches from a given VN, the NVE can reclaim state associated
with that VN.</t>
<t>For tenant unicast traffic, an NVE maintains a per-VN table of
mappings from Tenant System (inner) addresses to remote NVE
(outer) addresses.</t>
<t>For tenant multicast (or broadcast) traffic, an NVE maintains a
per-VN table of mappings and other information on how to deliver
tenant multicast (or broadcast) traffic. If the underlying network
supports IP multicast, the NVE could use IP multicast to deliver
tenant traffic. In such a case, the NVE would need to know what IP
underlay multicast address to use for a given VN. Alternatively,
if the underlying network does not support multicast, a source NVE
could use unicast replication to deliver traffic. In such a case,
an NVE would need to know which remote NVEs are participating in
the VN. An NVE could use both approaches, switching from one mode
to the other depending on such factors as bandwidth efficiency and
group membership sparseness. <xref
target="I-D.ietf-nvo3-mcast-framework"/> discusses the subject of
multicast handling in NVO3 in further detail.</t>
<t>An NVE maintains necessary information to encapsulate outgoing
traffic, including what type of encapsulation and what value to
use for a Context ID to identify the VN within the encapsulation
header.</t>
<t>In order to deliver incoming encapsulated packets to the
correct Tenant Systems, an NVE maintains the necessary information
to map incoming traffic to the appropriate VAP (i.e., Tenant
System Interface).</t>
<t>An NVE may find it convenient to maintain additional per-VN
information such as QoS settings, Path MTU information, ACLs,
etc.</t>
</list></t>
</section>
<section anchor="multi-homing" title="Multi-Homing of NVEs">
<t>NVEs may be multi-homed. That is, an NVE may have more than one IP
address associated with it on the underlay network. Multihoming
happens in two different scenarios. First, an NVE may have multiple
interfaces connecting it to the underlay. Each of those interfaces
will typically have a different IP address, resulting in a specific
Tenant Address (on a specific VN) being reachable through the same NVE
but through more than one underlay IP address. Second, a specific
tenant system may be reachable through more than one NVE, each having
one or more underlay addresses. In both cases, NVE address mapping
functionality needs to support one-to-many mappings and enable a
sending NVE to (at a minimum) be able to fail over from one IP address
to another, e.g., should a specific NVE underlay address become
unreachable.</t>
<t>Finally, multi-homed NVEs introduce complexities when source
unicast replication is used to implement tenant multicast as described
in Section 4.3. Specifically, an NVE should only receive one copy of a
replicated packet.</t>
<t>Multi-homing is needed to support important use cases. First, a
bare metal server may have multiple uplink connections to either the
same or different NVEs. Having only a single physical path to an
upstream NVE, or indeed, having all traffic flow through a single NVE
would be considered unacceptable in highly-resilient deployment
scenarios that seek to avoid single points of failure. Moreover, in
today's networks, the availability of multiple paths would require
that they be usable in an active-active fashion (e.g., for load
balancing).</t>
</section>
<section anchor="vap-error" title="Virtual Access Point (VAP)">
<t>The VAP is the NVE-side of the interface between the NVE and the
TS. Traffic to and from the tenant flows through the VAP. If an NVE
runs into difficulties sending traffic received on the VAP, it may
need to signal such errors back to the VAP. Because the VAP is an
emulation of a physical port, its ability to signal NVE errors is
limited and lacks sufficient granularity to reflect all possible
errors an NVE may encounter (e.g., inability reach a particular
destination). Some errors, such as an NVE losing all of its
connections to the underlay, could be reflected back to the VAP by
effectively disabling it. This state change would reflect itself on
the TS as an interface going down, allowing the TS to implement
interface error handling, e.g., failover, in the same manner as when a
physical interfaces becomes disabled.</t>
</section>
</section>
<section title="Tenant System Types">
<t>This section describes a number of special Tenant System types and
how they fit into an NVO3 system.</t>
<section anchor="data-appliance"
title="Overlay-Aware Network Service Appliances">
<t>Some Network Service Appliances <xref
target="I-D.ietf-nvo3-nve-nva-cp-req"/> (virtual or physical) provide
tenant-aware services. That is, the specific service they provide
depends on the identity of the tenant making use of the service. For
example, firewalls are now becoming available that support
multi-tenancy where a single firewall provides virtual firewall
service on a per-tenant basis, using per-tenant configuration rules
and maintaining per-tenant state. Such appliances will be aware of the
VN an activity corresponds to while processing requests. Unlike server
virtualization, which shields VMs from needing to know about
multi-tenancy, a Network Service Appliance may explicitly support
multi-tenancy. In such cases, the Network Service Appliance itself
will be aware of network virtualization and either embed an NVE
directly, or implement a split NVE as described in <xref
target="split-nve"/>. Unlike server virtualization, however, the
Network Service Appliance may not be running a hypervisor and the VM
orchestration system may not interact with the Network Service
Appliance. The NVE on such appliances will need to support a control
plane to obtain the necessary information needed to fully participate
in an NV Domain.</t>
</section>
<section title="Bare Metal Servers">
<t>Many data centers will continue to have at least some servers
operating as non-virtualized (or "bare metal") machines running a
traditional operating system and workload. In such systems, there will
be no NVE functionality on the server, and the server will have no
knowledge of NVO3 (including whether overlays are even in use). In
such environments, the NVE functionality can reside on the first-hop
physical switch. In such a case, the network administrator would
(manually) configure the switch to enable the appropriate NVO3
functionality on the switch port connecting the server and associate
that port with a specific virtual network. Such configuration would
typically be static, since the server is not virtualized, and once
configured, is unlikely to change frequently. Consequently, this
scenario does not require any protocol or standards work.</t>
</section>
<section title="Gateways">
<t>Gateways on VNs relay traffic onto and off of a virtual network.
Tenant Systems use gateways to reach destinations outside of the local
VN. Gateways receive encapsulated traffic from one VN, remove the
encapsulation header, and send the native packet out onto the data
center network for delivery. Outside traffic enters a VN in a reverse
manner.</t>
<t>Gateways can be either virtual (i.e., implemented as a VM) or
physical (i.e., as a standalone physical device). For performance
reasons, standalone hardware gateways may be desirable in some cases.
Such gateways could consist of a simple switch forwarding traffic from
a VN onto the local data center network, or could embed router
functionality. On such gateways, network interfaces connecting to
virtual networks will (at least conceptually) embed NVE (or split-NVE)
functionality within them. As in the case with Network Service
Appliances, gateways may not support a hypervisor and will need an
appropriate control plane protocol to obtain the information needed to
provide NVO3 service.</t>
<t>Gateways handle several different use cases. For example, one use
case consists of systems supporting overlays together with systems
that do not (e.g., bare metal servers). Gateways could be used to
connect legacy systems supporting, e.g., L2 VLANs, to specific virtual
networks, effectively making them part of the same virtual network.
Gateways could also forward traffic between a virtual network and
other hosts on the data center network or relay traffic between
different VNs. Finally, gateways can provide external connectivity
such as Internet or VPN access.</t>
<section title="Gateway Taxonomy">
<t>As can be seen from the discussion above, there are several types
of gateways that can exist in an NVO3 environment. This section
breaks them down into the various types that could be supported.
Note that each of the types below could be implemented in either a
centralized manner or distributed to co-exist with the NVEs.</t>
<section title="L2 Gateways (Bridging)">
<t>L2 Gateways act as layer 2 bridges to forward Ethernet frames
based on the MAC addresses present in them.</t>
<t><list hangIndent="6" style="hanging">
<t hangText="L2 VN to Legacy L2:">This type of gateway bridges
traffic between L2 VNs and other legacy L2 networks such as
VLANs or L2 VPNs.</t>
<t hangText="L2 VN to L2 VN:">The main motivation for this
type of gateway to create separate groups of Tenant Systems
using L2 VNs such that the gateway can enforce network
policies between each L2 VN.</t>
</list></t>
</section>
<section title="L3 Gateways (Only IP Packets)">
<t>L3 Gateways forward IP packets based on the IP addresses
present in the packets.</t>
<t><list hangIndent="6" style="hanging">
<t hangText="L3 VN to Legacy L2:">This type of gateway
forwards packets between L3 VNs and legacy L2 networks such as
VLANs or L2 VPNs. The original sender's destination MAC
address in any frames that the gateway forwards from a legacy
L2 network would be the MAC address of the gateway.</t>
<t hangText="L3 VN to Legacy L3:">The type of gateway forwards
packets between L3 VNs and legacy L3 networks. These legacy L3
networks could be local the data center, in the WAN, or an L3
VPN.</t>
<t hangText="L3 VN to L2 VN:">This type of gateway forwards
packets on between L3 VNs and L2 VNs. The original sender's
destination MAC address in any frames that the gateway
forwards from a L2 VN would be the MAC address of the
gateway.</t>
<t hangText="L2 VN to L2 VN:">This type of gateway acts
similar to a traditional router that forwards between L2
interfaces. The original sender's destination MAC address in
any frames that the gateway forwards from any of the L2 VNs
would be the MAC address of the gateway.</t>
<t hangText="L3 VN to L3 VN:">The main motivation for this
type of gateway to create separate groups of Tenant Systems
using L3 VNs such that the gateway can enforce network
policies between each L3 VN.</t>
</list></t>
</section>
</section>
</section>
<section title="Distributed Inter-VN Gateways">
<t>The relaying of traffic from one VN to another deserves special
consideration. Whether traffic is permitted to flow from one VN to
another is a matter of policy, and would not (by default) be allowed
unless explicitly enabled. In addition, NVAs are the logical place to
maintain policy information about allowed inter-VN communication.
Policy enforcement for inter-VN communication can be handled in (at
least) two different ways. Explicit gateways could be the central
point for such enforcement, with all inter-VN traffic forwarded to
such gateways for processing. Alternatively, the NVA can provide such
information directly to NVEs, by either providing a mapping for a
target Tenant System (TS) on another VN, or indicating that such
communication is disallowed by policy.</t>
<t>When inter-VN gateways are centralized, traffic between TSs on
different VNs can take suboptimal paths, i.e., triangular routing
results in paths that always traverse the gateway. In the worst case,
traffic between two TSs connected to the same NVE can be hair-pinned
through an external gateway. As an optimization, individual NVEs can
be part of a distributed gateway that performs such relaying, reducing
or completely eliminating triangular routing. In a distributed
gateway, each ingress NVE can perform such relaying activity directly,
so long as it has access to the policy information needed to determine
whether cross-VN communication is allowed. Having individual NVEs be
part of a distributed gateway allows them to tunnel traffic directly
to the destination NVE without the need to take suboptimal paths.</t>
<t>The NVO3 architecture supports distributed gateways for the case of
inter-VN communication. Such support requires that NVO3 control
protocols include mechanisms for the maintenance and distribution of
policy information about what type of cross-VN communication is
allowed so that NVEs acting as distributed gateways can tunnel traffic
from one VN to another as appropriate.</t>
<t>Distributed gateways could also be used to distribute other
traditional router services to individual NVEs. The NVO3 architecture
does not preclude such implementations, but does not define or require
them as they are outside the scope of the NVO3 architecture.</t>
</section>
<section anchor="arp-and-nd" title="ARP and Neighbor Discovery">
<t>For an L2 service, strictly speaking, special processing of Address
Resolution Protocol (ARP) <xref target="RFC0826"/> (and IPv6 Neighbor
Discovery (ND) <xref target="RFC4861"/>) is not required. ARP requests
are broadcast, and an NVO3 can deliver ARP requests to all members of
a given L2 virtual network, just as it does for any packet sent to an
L2 broadcast address. Similarly, ND requests are sent via IP
multicast, which NVO3 can support by delivering via L2 multicast.
However, as a performance optimization, an NVE can intercept ARP (or
ND) requests from its attached TSs and respond to them directly using
information in its mapping tables. Since an NVE will have mechanisms
for determining the NVE address associated with a given TS, the NVE
can leverage the same mechanisms to suppress sending ARP and ND
requests for a given TS to other members of the VN. The NVO3
architecture supports such a capability.</t>
</section>
</section>
<section anchor="nve-to-nve" title="NVE-NVE Interaction">
<t>Individual NVEs will interact with each other for the purposes of
tunneling and delivering traffic to remote TSs. At a minimum, a control
protocol may be needed for tunnel setup and maintenance. For example,
tunneled traffic may need to be encrypted or integrity protected, in
which case it will be necessary to set up appropriate security
associations between NVE peers. It may also be desirable to perform
tunnel maintenance (e.g., continuity checks) on a tunnel in order to
detect when a remote NVE becomes unreachable. Such generic tunnel setup
and maintenance functions are not generally NVO3-specific. Hence, the
NVO3 architecture expects to leverage existing tunnel maintenance
protocols rather than defining new ones.</t>
<t>Some NVE-NVE interactions may be specific to NVO3 (and in particular
be related to information kept in mapping tables) and agnostic to the
specific tunnel type being used. For example, when tunneling traffic for
TS-X to a remote NVE, it is possible that TS-X is not presently
associated with the remote NVE. Normally, this should not happen, but
there could be race conditions where the information an NVE has learned
from the NVA is out-of-date relative to actual conditions. In such
cases, the remote NVE could return an error or warning indication,
allowing the sending NVE to attempt a recovery or otherwise attempt to
mitigate the situation.</t>
<t>The NVE-NVE interaction could signal a range of indications, for
example:</t>
<t><list style="symbols">
<t>"No such TS here", upon a receipt of a tunneled packet for an
unknown TS.</t>
<t>"TS-X not here, try the following NVE instead" (i.e., a
redirect).</t>
<t>Delivered to correct NVE, but could not deliver packet to
TS-X.</t>
</list></t>
<t>When an NVE receives information from a remote NVE that conflicts
with the information it has in its own mapping tables, it should consult
with the NVA to resolve those conflicts. In particular, it should
confirm that the information it has is up-to-date, and it might indicate
the error to the NVA, so as to nudge the NVA into following up (as
appropriate). While it might make sense for an NVE to update its mapping
table temporarily in response to an error from a remote NVE, any changes
must be handled carefully as doing so can raise security considerations
if the received information cannot be authenticated. That said, a
sending NVE might still take steps to mitigate a problem, such as
applying rate limiting to data traffic towards a particular NVE or
TS.</t>
</section>
<section anchor="nva-section" title="Network Virtualization Authority">
<t>Before sending to and receiving traffic from a virtual network, an
NVE must obtain the information needed to build its internal forwarding
tables and state as listed in <xref target="nve-state"/>. An NVE can
obtain such information from a Network Virtualization Authority.</t>
<t>The Network Virtualization Authority (NVA) is the entity that is
expected to provide address mapping and other information to NVEs. NVEs
can interact with an NVA to obtain any required information they need in
order to properly forward traffic on behalf of tenants. The term NVA
refers to the overall system, without regards to its scope or how it is
implemented.</t>
<section title="How an NVA Obtains Information">
<t>There are two primary ways in which an NVA can obtain the address
dissemination information it manages. The NVA can obtain information
either from the VM orchestration system, and/or directly from the NVEs
themselves.</t>
<t>On virtualized systems, the NVA may be able to obtain the address
mapping information associated with VMs from the VM orchestration
system itself. If the VM orchestration system contains a master
database for all the virtualization information, having the NVA obtain
information directly to the orchestration system would be a natural
approach. Indeed, the NVA could effectively be co-located with the VM
orchestration system itself. In such systems, the VM orchestration
system communicates with the NVE indirectly through the
hypervisor.</t>
<t>However, as described in <xref target="nve-section2"/> not all NVEs
are associated with hypervisors. In such cases, NVAs cannot leverage
VM orchestration protocols to interact with an NVE and will instead
need to peer directly with them. By peering directly with an NVE, NVAs
can obtain information about the TSs connected to that NVE and can
distribute information to the NVE about the VNs those TSs are
associated with. For example, whenever a Tenant System attaches to an
NVE, that NVE would notify the NVA that the TS is now associated with
that NVE. Likewise when a TS detaches from an NVE, that NVE would
inform the NVA. By communicating directly with NVEs, both the NVA and
the NVE are able to maintain up-to-date information about all active
tenants and the NVEs to which they are attached.</t>
</section>
<section title="Internal NVA Architecture">
<t>For reliability and fault tolerance reasons, an NVA would be
implemented in a distributed or replicated manner without single
points of failure. How the NVA is implemented, however, is not
important to an NVE so long as the NVA provides a consistent and
well-defined interface to the NVE. For example, an NVA could be
implemented via database techniques whereby a server stores address
mapping information in a traditional (possibly replicated) database.
Alternatively, an NVA could be implemented in a distributed fashion
using an existing (or modified) routing protocol to maintain and
distribute mappings. So long as there is a clear interface between the
NVE and NVA, how an NVA is architected and implemented is not
important to an NVE.</t>
<t>A number of architectural approaches could be used to implement
NVAs themselves. NVAs manage address bindings and distribute them to
where they need to go. One approach would be to use Border Gateway
Protocol (BGP) <xref target="RFC4364"/> (possibly with extensions) and
route reflectors. Another approach could use a transaction-based
database model with replicated servers. Because the implementation
details are local to an NVA, there is no need to pick exactly one
solution technology, so long as the external interfaces to the NVEs
(and remote NVAs) are sufficiently well defined to achieve
interoperability.</t>
</section>
<section title="NVA External Interface">
<t>Conceptually, from the perspective of an NVE, an NVA is a single
entity. An NVE interacts with the NVA, and it is the NVA's
responsibility for ensuring that interactions between the NVE and NVA
result in consistent behavior across the NVA and all other NVEs using
the same NVA. Because an NVA is built from multiple internal
components, an NVA will have to ensure that information flows to all
internal NVA components appropriately.</t>
<t>One architectural question is how the NVA presents itself to the
NVE. For example, an NVA could be required to provide access via a
single IP address. If NVEs only have one IP address to interact with,
it would be the responsibility of the NVA to handle NVA component
failures, e.g., by using a "floating IP address" that migrates among
NVA components to ensure that the NVA can always be reached via the
one address. Having all NVA accesses through a single IP address,
however, adds constraints to implementing robust failover, load
balancing, etc.</t>
<t>In the NVO3 architecture, an NVA is accessed through one or more IP
addresses (or IP address/port combination). If multiple IP addresses
are used, each IP address provides equivalent functionality, meaning
that an NVE can use any of the provided addresses to interact with the
NVA. Should one address stop working, an NVE is expected to failover
to another. While the different addresses result in equivalent
functionality, one address may respond more quickly than another,
e.g., due to network conditions, load on the server, etc.</t>
<t>To provide some control over load balancing, NVA addresses may have
an associated priority. Addresses are used in order of priority, with
no explicit preference among NVA addresses having the same priority.
To provide basic load-balancing among NVAs of equal priorities, NVEs
could use some randomization input to select among equal-priority
NVAs. Such a priority scheme facilitates failover and load balancing,
for example, allowing a network operator to specify a set of primary
and backup NVAs.</t>
<t>It may be desirable to have individual NVA addresses responsible
for a subset of information about an NV Domain. In such a case, NVEs
would use different NVA addresses for obtaining or updating
information about particular VNs or TS bindings. A key question with
such an approach is how information would be partitioned, and how an
NVE could determine which address to use to get the information it
needs.</t>
<t>Another possibility is to treat the information on which NVA
addresses to use as cached (soft-state) information at the NVEs, so
that any NVA address can be used to obtain any information, but NVEs
are informed of preferences for which addresses to use for particular
information on VNs or TS bindings. That preference information would
be cached for future use to improve behavior - e.g., if all requests
for a specific subset of VNs are forwarded to a specific NVA
component, the NVE can optimize future requests within that subset by
sending them directly to that NVA component via its address.</t>
</section>
</section>
<section anchor="nve-to-nva" title="NVE-to-NVA Protocol">
<t>As outlined in <xref target="nve-state"/>, an NVE needs certain
information in order to perform its functions. To obtain such
information from an NVA, an NVE-to-NVA protocol is needed. The
NVE-to-NVA protocol provides two functions. First it allows an NVE to
obtain information about the location and status of other TSs with which
it needs to communicate. Second, the NVE-to-NVA protocol provides a way
for NVEs to provide updates to the NVA about the TSs attached to that
NVE (e.g., when a TS attaches or detaches from the NVE), or about
communication errors encountered when sending traffic to remote NVEs.
For example, an NVE could indicate that a destination it is trying to
reach at a destination NVE is unreachable for some reason.</t>
<t>While having a direct NVE-to-NVA protocol might seem straightforward,
the existence of existing VM orchestration systems complicates the
choices an NVE has for interacting with the NVA.</t>
<section title="NVE-NVA Interaction Models">
<t>An NVE interacts with an NVA in at least two (quite different)
ways:</t>
<t><list style="symbols">
<t>NVEs embedded within the same server as the hypervisor can
obtain necessary information entirely through the
hypervisor-facing side of the NVE. Such an approach is a natural
extension to existing VM orchestration systems supporting server
virtualization because an existing protocol between the hypervisor
and VM orchestration system already exists and can be leveraged to
obtain any needed information. Specifically, VM orchestration
systems used to create, terminate and migrate VMs already use
well-defined (though typically proprietary) protocols to handle
the interactions between the hypervisor and VM orchestration
system. For such systems, it is a natural extension to leverage
the existing orchestration protocol as a sort of proxy protocol
for handling the interactions between an NVE and the NVA. Indeed,
existing implementations can already do this.</t>
<t>Alternatively, an NVE can obtain needed information by
interacting directly with an NVA via a protocol operating over the
data center underlay network. Such an approach is needed to
support NVEs that are not associated with systems performing
server virtualization (e.g., as in the case of a standalone
gateway) or where the NVE needs to communicate directly with the
NVA for other reasons.</t>
</list></t>
<t>The NVO3 architecture will focus on support for the second model
above. Existing virtualization environments are already using the
first model. But they are not sufficient to cover the case of
standalone gateways -- such gateways may not support virtualization
and do not interface with existing VM orchestration systems.</t>
</section>
<section title="Direct NVE-NVA Protocol">
<t>An NVE can interact directly with an NVA via an NVE-to-NVA
protocol. Such a protocol can be either independent of the NVA
internal protocol, or an extension of it. Using a purpose-specific
protocol would provide architectural separation and independence
between the NVE and NVA. The NVE and NVA interact in a well-defined
way, and changes in the NVA (or NVE) do not need to impact each other.
Using a dedicated protocol also ensures that both NVE and NVA
implementations can evolve independently and without dependencies on
each other. Such independence is important because the upgrade path
for NVEs and NVAs is quite different. Upgrading all the NVEs at a site
will likely be more difficult in practice than upgrading NVAs because
of their large number - one on each end device. In practice, it would
be prudent to assume that once an NVE has been implemented and
deployed, it may be challenging to get subsequent NVE extensions and
changes implemented and deployed, whereas an NVA (and its associated
internal protocols) are more likely to evolve over time as experience
is gained from usage and upgrades will involve fewer nodes.</t>
<t>Requirements for a direct NVE-NVA protocol can be found in <xref
target="I-D.ietf-nvo3-nve-nva-cp-req"/></t>
</section>
<section title="Propagating Information Between NVEs and NVAs">
<t>Information flows between NVEs and NVAs in both directions. The NVA
maintains information about all VNs in the NV Domain, so that NVEs do
not need to do so themselves. NVEs obtain from the NVA information
about where a given remote TS destination resides. NVAs in turn obtain
information from NVEs about the individual TSs attached to those
NVEs.</t>
<t>While the NVA could push information relevant to every virtual
network to every NVE, such an approach scales poorly and is
unnecessary. In practice, a given NVE will only need and want to know
about VNs to which it is attached. Thus, an NVE should be able to
subscribe to updates only for the virtual networks it is interested in
receiving updates for. The NVO3 architecture supports a model where an
NVE is not required to have full mapping tables for all virtual
networks in an NV Domain.</t>
<t>Before sending unicast traffic to a remote TS (or TSes for
broadcast or multicast traffic), an NVE must know where the remote
TS(es) currently reside. When a TS attaches to a virtual network, the
NVE obtains information about that VN from the NVA. The NVA can
provide that information to the NVE at the time the TS attaches to the
VN, either because the NVE requests the information when the attach
operation occurs, or because the VM orchestration system has initiated
the attach operation and provides associated mapping information to
the NVE at the same time.</t>
<t>There are scenarios where an NVE may wish to query the NVA about
individual mappings within an VN. For example, when sending traffic to
a remote TS on a remote NVE, that TS may become unavailable (e.g,.
because it has migrated elsewhere or has been shutdown, in which case
the remote NVE may return an error indication). In such situations,
the NVE may need to query the NVA to obtain updated mapping
information for a specific TS, or verify that the information is still
correct despite the error condition. Note that such a query could also
be used by the NVA as an indication that there may be an inconsistency
in the network and that it should take steps to verify that the
information it has about the current state and location of a specific
TS is still correct.</t>
<t>For very large virtual networks, the amount of state an NVE needs
to maintain for a given virtual network could be significant.
Moreover, an NVE may only be communicating with a small subset of the
TSs on such a virtual network. In such cases, the NVE may find it
desirable to maintain state only for those destinations it is actively
communicating with. In such scenarios, an NVE may not want to maintain
full mapping information about all destinations on a VN. Should it
then need to communicate with a destination for which it does not have
mapping information, however, it will need to be able to query the NVA
on demand for the missing information on a per-destination basis.</t>
<t>The NVO3 architecture will need to support a range of operations
between the NVE and NVA. Requirements for those operations can be
found in <xref target="I-D.ietf-nvo3-nve-nva-cp-req"/>.</t>
</section>
</section>
<section title="Federated NVAs">
<t>An NVA provides service to the set of NVEs in its NV Domain. Each NVA
manages network virtualization information for the virtual networks
within its NV Domain. An NV domain is administered by a single
entity.</t>
<t>In some cases, it will be necessary to expand the scope of a specific
VN or even an entire NV domain beyond a single NVA. For example,
multiple data centers managed by the same administrator may wish to
operate all of its data centers as a single NV region. Such cases are
handled by having different NVAs peer with each other to exchange
mapping information about specific VNs. NVAs operate in a federated
manner with a set of NVAs operating as a loosely-coupled federation of
individual NVAs. If a virtual network spans multiple NVAs (e.g., located
at different data centers), and an NVE needs to deliver tenant traffic
to an NVE that is part of a different NV Domain, it still interacts only
with its NVA, even when obtaining mappings for NVEs associated with a
different NV Domain.</t>
<t><xref target="nva-federation"/> shows a scenario where two separate
NV Domains (1 and 2) share information about Virtual Network "1217". VM1
and VM2 both connect to the same Virtual Network 1217, even though the
two VMs are in separate NV Domains. There are two cases to consider. In
the first case, NV Domain B (NVB) does not allow NVE-A to tunnel traffic
directly to NVE-B. There could be a number of reasons for this. For
example, NV Domains 1 and 2 may not share a common address space (i.e.,
require traversal through a NAT device), or for policy reasons, a domain
might require that all traffic between separate NV Domains be funneled
through a particular device (e.g., a firewall). In such cases, NVA-2
will advertise to NVA-1 that VM1 on Virtual Network 1217 is available,
and direct that traffic between the two nodes go through IP-G. IP-G
would then decapsulate received traffic from one NV Domain, translate it
appropriately for the other domain and re-encapsulate the packet for
delivery.</t>
<figure anchor="nva-federation"
title="VM1 and VM2 are in different NV Domains.">
<artwork name="nve-reference-model"><![CDATA[
xxxxxx xxxx +-----+
+-----+ xxxxxx xxxxxx xxxxxx xxxxx | VM2 |
| VM1 | xx xx xxx xx |-----|
|-----| xx x xx x |NVE-B|
|NVE-A| x x +----+ x x +-----+
+--+--+ x NV Domain A x |IP-G|--x x |
+-------x xx--+ | x xx |
x x +----+ x NV Domain B x |
+---x xx xx x---+
| xxxx xx +->xx xx
| xxxxxxxx | xx xx
+---+-+ | xx xx
|NVA-1| +--+--+ xx xxx
+-----+ |NVA-2| xxxx xxxx
+-----+ xxxxx
]]></artwork>
</figure>
<t>NVAs at one site share information and interact with NVAs at other
sites, but only in a controlled manner. It is expected that policy and
access control will be applied at the boundaries between different sites
(and NVAs) so as to minimize dependencies on external NVAs that could
negatively impact the operation within a site. It is an architectural
principle that operations involving NVAs at one site not be immediately
impacted by failures or errors at another site. (Of course,
communication between NVEs in different NV domains may be impacted by
such failures or errors.) It is a strong requirement that an NVA
continue to operate properly for local NVEs even if external
communication is interrupted (e.g., should communication between a local
and remote NVA fail).</t>
<t>At a high level, a federation of interconnected NVAs has some
analogies to BGP and Autonomous Systems. Like an Autonomous System, NVAs
at one site are managed by a single administrative entity and do not
interact with external NVAs except as allowed by policy. Likewise, the
interface between NVAs at different sites is well defined, so that the
internal details of operations at one site are largely hidden to other
sites. Finally, an NVA only peers with other NVAs that it has a trusted
relationship with, i.e., where a VN is intended to span multiple
NVAs.</t>
<t>Reasons for using a federated model include: <list style="symbols">
<t>Provide isolation among NVAs operating at different sites at
different geographic locations.</t>
<t>Control the quantity and rate of information updates that flow
(and must be processed) between different NVAs in different data
centers.</t>
<t>Control the set of external NVAs (and external sites) a site
peers with. A site will only peer with other sites that are
cooperating in providing an overlay service.</t>
<t>Allow policy to be applied between sites. A site will want to
carefully control what information it exports (and to whom) as well
as what information it is willing to import (and from whom).</t>
<t>Allow different protocols and architectures to be used for intra-
vs. inter-NVA communication. For example, within a single data
center, a replicated transaction server using database techniques
might be an attractive implementation option for an NVA, and
protocols optimized for intra-NVA communication would likely be
different from protocols involving inter-NVA communication between
different sites.</t>
<t>Allow for optimized protocols, rather than using a one-size-fits
all approach. Within a data center, networks tend to have
lower-latency, higher-speed and higher redundancy when compared with
WAN links interconnecting data centers. The design constraints and
tradeoffs for a protocol operating within a data center network are
different from those operating over WAN links. While a single
protocol could be used for both cases, there could be advantages to
using different and more specialized protocols for the intra- and
inter-NVA case.</t>
</list></t>
<section title="Inter-NVA Peering">
<t>To support peering between different NVAs, an inter-NVA protocol is
needed. The inter-NVA protocol defines what information is exchanged
between NVAs. It is assumed that the protocol will be used to share
addressing information between data centers and must scale well over
WAN links.</t>
</section>
</section>
<section title="Control Protocol Work Areas">
<t>The NVO3 architecture consists of two major distinct entities: NVEs
and NVAs. In order to provide isolation and independence between these
two entities, the NVO3 architecture calls for well defined protocols for
interfacing between them. For an individual NVA, the architecture calls
for a logically centralized entity that could be implemented in a
distributed or replicated fashion. While the IETF may choose to define
one or more specific architectural approaches to building individual
NVAs, there is little need for it to pick exactly one approach to the
exclusion of others. An NVA for a single domain will likely be deployed
as a single vendor product and thus there is little benefit in
standardizing the internal structure of an NVA.</t>
<t>Individual NVAs peer with each other in a federated manner. The NVO3
architecture calls for a well-defined interface between NVAs.</t>
<t>Finally, a hypervisor-to-NVE protocol is needed to cover the
split-NVE scenario described in <xref target="split-nve"/>.</t>
</section>
<section title="NVO3 Data Plane Encapsulation">
<t>When tunneling tenant traffic, NVEs add encapsulation header to the
original tenant packet. The exact encapsulation to use for NVO3 does not
seem to be critical. The main requirement is that the encapsulation
support a Context ID of sufficient size. A number of encapsulations
already exist that provide a VN Context of sufficient size for NVO3. For
example, VXLAN <xref target="RFC7348"/> has a 24-bit VXLAN Network
Identifier (VNI). NVGRE <xref target="RFC7637"/> has a 24-bit Tenant
Network ID (TNI). MPLS-over-GRE provides a 20-bit label field. While
there is widespread recognition that a 12-bit VN Context would be too
small (only 4096 distinct values), it is generally agreed that 20 bits
(1 million distinct values) and 24 bits (16.8 million distinct values)
are sufficient for a wide variety of deployment scenarios.</t>
</section>
<section title="Operations, Administration and Maintenance (OAM)">
<t>The simplicity of operating and debugging overlay networks will be
critical for successful deployment.</t>
<t>Overlay networks are based on tunnels between NVEs, so the OAM
(Operations, Administration and Maintenance) <xref target="RFC6291"/>
framework for overlay networks can draw from prior IETF OAM work for
tunnel-based networks, specifically L2VPN OAM <xref target="RFC6136"/>.
RFC 6136 focuses on Fault Management and Performance Management as
fundamental to L2VPN service delivery, leaving the Configuration,
Management, Accounting Management and Security Management components of
the OSI "FCAPS" taxonomy <xref target="M.3400"/> for further study. This
section does likewise for NVO3 OAM, but those three areas continue to be
important parts of complete OAM functionality for NVO3.</t>
<t>The relationship between the overlay and underlay networks is a
consideration for fault and performance management - a fault in the
underlay may manifest as fault and/or performance issues in the overlay.
Diagnosing and fixing such issues are complicated by NVO3 abstracting
the underlay network away from the overlay network (e.g., intermediate
nodes on the underlay network path between NVEs are hidden from overlay
VNs).</t>
<t>NVO3-specific OAM techniques, protocol constructs and tools are
needed to provide visibility beyond this abstraction to diagnose and
correct problems that appear in the overlay. Two examples are
underlay-aware traceroute <xref
target="I-D.nordmark-nvo3-transcending-traceroute"/>, and ping protocol
constructs for overlay networks <xref
target="I-D.jain-nvo3-vxlan-ping"/> <xref
target="I-D.kumar-nvo3-overlay-ping"/>.</t>
<t>NVO3-specific tools and techniques are best viewed as complements to
(i.e., not as replacements for) single-network tools that apply to the
overlay and/or underlay networks. Coordination among the individual
network tools (for the overlay and underlay networks) and NVO3-aware
dual-network tools is required to achieve effective monitoring and fault
diagnosis. For example, the defect detection intervals and performance
measurement intervals ought to be coordinated among all tools involved
in order to provide consistency and comparability of results.</t>
<t>For further discussion of NVO3 OAM requirements, see <xref
target="I-D.ashwood-nvo3-oam-requirements"/>.</t>
</section>
<section title="Summary">
<t>This document presents the overall architecture for Network
Virtualization Overlays (NVO3). The architecture calls for three main
areas of protocol work:</t>
<t><list style="numbers">
<t>A hypervisor-to-NVE protocol to support Split NVEs as discussed
in <xref target="split-nve"/>.</t>
<t>An NVE to NVA protocol for disseminating VN information (e.g.,
inner to outer address mappings).</t>
<t>An NVA-to-NVA protocol for exchange of information about specific
virtual networks between federated NVAs.</t>
</list></t>
<t>It should be noted that existing protocols or extensions of existing
protocols are applicable.</t>
</section>
<section anchor="Acknowledgments" title="Acknowledgments">
<t>Helpful comments and improvements to this document have come from
Alia Atlas, Abdussalam Baryun, Spencer Dawkins, Linda Dunbar, Stephen
Farrell, Anton Ivanov, Lizhong Jin, Suresh Krishnan, Mirja Kuehlwind,
Greg Mirsky, Carlos Pignataro, Dennis (Xiaohong) Qin, Erik Smith,
Takeshi Takahashi, Ziye Yang and Lucy Yong.</t>
</section>
<!-- Possibly a 'Contributors' section ... -->
<section anchor="IANA" title="IANA Considerations">
<t>This memo includes no request to IANA.</t>
</section>
<section anchor="Security" title="Security Considerations">
<t>The data plane and control plane described in this architecture will
need to address potential security threats.</t>
<t>For the data plane, tunneled application traffic may need protection
against being misdelivered, modified, or having its content exposed to
an inappropriate third party. In all cases, encryption between
authenticated tunnel endpoints (e.g., via use of <xref
target="RFC4301">IPsec</xref>) and enforcing policies that control which
endpoints and VNs are permitted to exchange traffic can be used to
mitigate risks.</t>
<t>For the control plane, between NVAs, the NVA and NVE as well as
between different components of the split-NVE approach, a combination of
authentication and encryption can be used. All entities will need to
properly authenticate with each other and enable encryption for their
interactions as appropriate to protect sensitive information.</t>
<t>Leakage of sensitive information about users or other entities
associated with VMs whose traffic is virtualized can also be covered by
using encryption for the control plane protocols and enforcing policies
that control which NVO3 components are permitted to exchange control
plane traffic.</t>
<t>Control plane elements such as NVEs and NVAs need to collect
performance and other data in order to carry out their functions. This
data can sometimes be unexpectedly sensitive, for example, allowing
non-obvious inferences as to activity within a VM. This provides a
reason to minimise the data collected in some environments in order to
limit potential exposure of sensitive information. As noted briefly in
<xref target="RFC6973">RFC 6973</xref> and <xref target="RFC7258">RFC
7258</xref> there is an inevitable tension between being privacy
sensitive and network operations that needs to be taken into account in
nvo3 protocol development</t>
<t>See the NVO3 framework security considerations in <xref
target="RFC7365">RFC 7365</xref> for further discussion.</t>
</section>
</middle>
<!-- *****BACK MATTER ***** -->
<back>
<!-- References split into informative and normative -->
<!-- There are 2 ways to insert reference entries from the citation libraries:
1. define an ENTITY at the top, and use "ampersand character"RFC2629; here (as shown)
2. simply use a PI "less than character"?rfc include="reference.RFC.2119.xml"?> here
(for I-Ds: include="reference.I-D.narten-iana-considerations-rfc2434bis.xml")
Both are cited textually in the same manner: by using xref elements.
If you use the PI option, xml2rfc will, by default, try to find included files in the same
directory as the including file. You can also define the XML_LIBRARY environment variable
with a value containing a set of directories to search. These can be either in the local
filing system or remote ones accessed by http (http://domain/dir/... ).-->
<references title="Informative References">
<!-- Here we use entities that we defined at the beginning. -->
<?rfc include="reference.I-D.ashwood-nvo3-oam-requirements" ?>
<?rfc include="reference.I-D.ietf-nvo3-nve-nva-cp-req" ?>
<?rfc include="reference.I-D.ietf-nvo3-mcast-framework" ?>
<?rfc include="reference.I-D.ietf-nvo3-use-case" ?>
<?rfc include="reference.I-D.jain-nvo3-vxlan-ping" ?>
<?rfc include="reference.I-D.kumar-nvo3-overlay-ping" ?>
<?rfc include="reference.I-D.nordmark-nvo3-transcending-traceroute" ?>
<?rfc include="reference.RFC.7637" ?>
<?rfc include="reference.RFC.7348" ?>
<?rfc include="reference.RFC.7364" ?>
<?rfc include="reference.RFC.7365" ?>
<?rfc include="reference.RFC.4364" ?>
<?rfc include="reference.RFC.4861" ?>
<?rfc include="reference.RFC.0826" ?>
<?rfc include="reference.RFC.6291" ?>
<?rfc include="reference.RFC.6136" ?>
<?rfc include="reference.RFC.4301" ?>
<?rfc include="reference.RFC.6973" ?>
<?rfc include="reference.RFC.7258" ?>
<reference anchor="IEEE-802.1Q">
<front>
<title>IEEE Standard for Local and metropolitan area networks:
Bridges and Bridged Networks</title>
<author fullname="" surname="IEEE Std 802.1Q-2014"/>
<date month="November" year="2014"/>
</front>
<format target="http://standards.ieee.org/getieee802/download/802-1Q-2014.pdf"
type="pdf"/>
</reference>
<reference anchor="M.3400">
<front>
<title>TMN management functions</title>
<author surname="ITU-T Recommendation M.3400"/>
<date month="February" year="2000"/>
</front>
<format target="https://www.itu.int/rec/T-REC-M.3400-200002-I/"
type="pdf"/>
</reference>
</references>
</back>
</rfc>